1 dari 1

BECKHOFF EP3162-0002 EtherCAT Box 2-Channel Analog Input Module

BECKHOFF EP3162-0002 EtherCAT Box 2-Channel Analog Input Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: EP3162-0002

  • Negara asal:Jerman

  • Jenis Produk: Analog Input Modules

  • Pembayaran: T/T, Western Union

  • Berat: 165g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Processing analog signals directly in harsh field environments is simplified with the EP3162-0002 EtherCAT Box. This IP67-rated decentralized module features two highly flexible, galvanically isolated analog inputs that are software-parameterizable for either voltage (-10/0 to +10 V) or current (-20/0/4 to +20 mA) signals on a per-channel basis. By executing analog-to-digital conversion directly at the sensor location, this module minimizes signal degradation over long wire runs, enabling clean 16-bit measurement resolution across distributed fieldbus networks.

The device features dual-channel isolation to eliminate ground loop issues, making it highly reliable in electrically noisy industrial applications. Connectivity is facilitated through robust, industry-standard M12 connectors for the sensor lines and M8 connectors for the EtherCAT fieldbus and power supply daisy-chaining. With integrated Distributed Clocks (DC) support, the module guarantees precise, synchronized data acquisition across large-scale industrial machinery.

Features

  • Two single-ended, individually parameterizable analog input channels.
  • Supports standard industrial signal ranges: -10 to +10 V, 0 to 10 V, -20 to +20 mA, 0 to 20 mA, and 4 to 20 mA.
  • Complete galvanic isolation between individual input channels for high signal integrity.
  • Fast analog-to-digital conversion time of approximately 100 microseconds per channel.
  • High-precision 16-bit digital resolution (including sign).
  • Distributed Clocks (DC) support for high-fidelity clock synchronization in time-critical tasks.
  • Rugged IP65/66/67 physical housing for direct mounting outside of control cabinets.

Applications

  • Decentralized process instrumentation and sensor monitoring in heavy industrial plants.
  • Hydraulics and pneumatic system pressure, flow, and temperature tracking.
  • Machine-mount data acquisition systems in automotive assembly and packaging lines.
  • Test bench environments requiring high-speed, synchronized analog measurements.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EP3162-0002
Product Type EtherCAT Box (Analog Input)
Number of Inputs 2 single-ended (galvanically isolated channels)
Signal Type (Voltage) -10/0...+10 V (parameterizable per channel)
Signal Type (Current) -20/0/4...+20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Measurement Error < ±0.3% (relative to full scale value)
Conversion Time ~ 100 microseconds
Input Filter Limit Frequency 5 kHz
Bus Interface Connection 2 x M8 socket, shielded, screw-type
Input Connection Method M12 x 1, 5-pin, A-coded
Nominal Supply Voltage 24 V DC (-15% / +20%)
Power Connection Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Current Consumption (Us) 120 mA
Sensor Supply Us derived from auxiliary voltage, electrically isolated
Electrical Isolation 500 V (fieldbus to signal), 300 V (signal to signal)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Weight approx. 165 g
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27

Connections and Interfaces

M12 Pin Connection Signal Assignment
Pin 1 +24 V DC Sensor Supply (Us)
Pin 2 Analog Input + (Voltage / Current)
Pin 3 GND Sensor Supply (Us)
Pin 4 Analog Input -
Pin 5 Shield / Functional Earth

Installation Guidelines

  • Mounting: Screw the module directly onto flat machine surfaces using the integrated mounting holes. Ensure the mounting plane is grounded.
  • Shielding: Use fully shielded M12 sensor cables and shielded M8 EtherCAT cabling to preserve signal integrity and prevent electromagnetic interference (EMI).
  • Power Daisy Chaining: When utilizing the downstream M8 power output, verify that the total current draw of downstream modules does not exceed the maximum power bus capacity.
  • Sealing: Unused M12 and M8 ports must be sealed with appropriate IP67 protection caps to maintain environmental integrity.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

Can the EP3162-0002 measure both voltage and current on different channels simultaneously?

Yes, each of the two analog input channels on the EP3162-0002 can be independently parameterized via TwinCAT software. One channel can be set for voltage measurements (e.g., -10 to +10 V) while the other handles current loops (e.g., 4 to 20 mA).

What is the level of electrical isolation provided between the two input channels?

The EP3162-0002 features galvanic isolation up to 300 V between the individual input channels, as well as 500 V isolation to the EtherCAT fieldbus, minimizing the risk of ground loops.

Does this module require a control cabinet for installation?

No, with its IP65/66/67-rated enclosure, the EP3162-0002 is designed for direct machine mounting in wet, dusty, or harsh environments without needing an electrical enclosure.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...