1 dari 1

Beckhoff EPI1809-0022 IO-Link Box

Beckhoff EPI1809-0022 IO-Link Box

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: EPI1809-0022

  • Negara asal:Jerman

  • Jenis Produk: IO-Link Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Facilitating decentralized field signal acquisition, the Beckhoff EPI1809-0022 interfaces sixteen 24 V DC digital inputs directly to an IO-Link master. This highly compact IO-Link box allows sensors to be connected directly in the field without requiring a protective electrical enclosure. The module operates as an IO-Link Class A device, exchanging process data and configuration parameters over a standardized point-to-point communication channel. The robust structural encapsulation ensures reliable functionality in harsh manufacturing zones where dust, moisture, and high mechanical vibration are prevalent.

Features

  • 16 Digital Inputs: High-density distribution with Type 3 input characteristics according to EN 61131-2.
  • IO-Link V1.1 Compliance: Supports the Class A specification with high-speed COM3 communication rates.
  • Configurable Filters: Input filter times are adjustable from 0 to 20 ms to accommodate various sensor responses.
  • Integrated Sensor Protection: A collective 0.5 A sensor supply is fully protected against short-circuit events.
  • Heavy-Duty Seal: IP65, IP66, and IP67 protection ratings enable direct field mounting.

Applications

  • Automotive assembly lines and conveyor networks.
  • Decentralized input monitoring on large packaging machinery.
  • Machine-mount sensor aggregation in washdown or wet processing areas.
  • Robotic end-of-arm tooling requiring lightweight signal hubs.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number EPI1809-0022
Communication Protocol IO-Link
IO-Link Specification Version V1.1, Class A
Data Transfer Rate 230.4 kbaud (COM3)
Primary Interface 1 x M12 plug, A-coded
Number of Inputs 16
Input Connections M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Range 3.0 ms (default), adjustable from 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current Typical 3 mA (EN 61131-2, type 3)
Sensor Supply Maximum 0.5 A from L+, short-circuit proof in total
Current Consumption Typical 100 mA from L+
Operating Temperature -25 to +60 Celsius
Storage Temperature -40 to +85 Celsius
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration & Shock Standards Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity & Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals CE, UL
Module Weight 250 g
Shipping Weight 2.0 kg
Country of Origin Germany

Empirical Engineering Insights

Alternative Models & Compatibility

The EPI1809-0022 uses Class A port assignment. Note that when replacing an older EP1809-0022 module, the control system must be adapted because the EP series operates natively on EtherCAT (requiring an EtherCAT master and XML descriptions), whereas the EPI series uses the IO-Link physical protocol layer under a master gateway. Verify that the master IO-Link port pinout matches the standard Class A configuration before commissioning.

Application Pitfalls & Engineering Notes

A common issue in field installations is overloading the sensor supply line. While individual input current is restricted to typical Type 3 parameters (3 mA), the aggregate sensor supply is capped at 0.5 A. If several high-current photo-electric proximity sensors or ultrasonic transducers are powered directly from this unit, the short-circuit protection mechanism will engage, shutting down auxiliary sensor power. Ensure a power budget calculation is done for all 16 connected devices.

Commissioning & Wiring Tips

When pairing the device with non-Beckhoff IO-Link masters, ensure that the correct manufacturer IODD configuration file is loaded into the engineering software (such as TwinCAT or TIA Portal) to correctly map the 16-channel process image. Tighten all unused M12 connections with protective caps to maintain the IP67 integrity; failure to seal unused ports can allow condensation to bridge contacts over time, causing intermittent "0" and "1" signal faults.

Installation Guidelines

CRITICAL WARNING: Prior to commencing any mechanical mounting or cable connection steps, completely de-energize the main 24 V DC system supply line to the IO-Link master unit. Do not plug or unplug M12 cables while under electrical load, as contact-arcing could damage sensitive semiconductor components in the internal transceiver circuit.
1

Mount the module directly to a flat, vibration-resistant surface using two M4 screws through the integrated chassis mounting holes. Ensure the installation position allows for adequate cable strain relief.

2

Securely plug the A-coded M12 IO-Link communication cable into the module's communication port and hand-tighten the coupling nut.

3

Connect the 16 digital input sensors to the appropriate M12 input channels. Utilize standard torque wrenches for M12 connectors to guarantee environmental sealing without over-tightening.

4

Power up the master system and configure the corresponding input filter settings and channel maps within your automation development workspace.

Loading product navigation…

Can the Beckhoff EPI1809-0022 be used on a Class B IO-Link master port?

Yes, it can be physically connected to a Class B master port, but it will only operate using the Class A pin configuration. Pin 2 and Pin 5 auxiliary supply lines of a Class B port are not utilized by this module.

What happens if a sensor line short-circuits on the EPI1809-0022?

The module features an integrated short-circuit proof sensor supply. If a fault is detected, the sensor power is limited to prevent hardware damage, and a diagnostic flag is raised in the IO-Link process data.

How are the input filters configured on this IO-Link box?

The input filters can be adjusted within a range of 0 to 20 ms (with a default setting of 3.0 ms) via the IO-Link parameters using your master's software tool or acyclic commands.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...