1 dari 1

BECKHOFF IE3202 Fieldbus Box 4-Channel Analog Input Extension Box

BECKHOFF IE3202 Fieldbus Box 4-Channel Analog Input Extension Box

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IE3202

  • Negara asal:Jerman

  • Jenis Produk: Extension Boxes

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for precise decentralized temperature acquisition, the BECKHOFF IE3202 Fieldbus Box extension module interfaces directly with resistive sensors in rugged, industrial environments. This IP67-rated analog input device facilitates the direct connection of up to four resistance thermometers without requiring protective control cabinets. By digitizing signals close to the physical process, it reduces noise susceptibility and cabling complexity.

The IE3202 supports a broad spectrum of RTD configurations, including standard Pt100, Pt200, Pt500, and Pt1000 sensors, alongside Ni100, Ni120, and Ni1000 variants. It also accommodates direct resistance measurements, such as those from potentiometers. Each of the four channels utilizes screw-type M12 connectors that can be wired in 2-wire, 3-wire, or 4-wire configurations (preset to 4-wire) to compensate for cable resistance errors and optimize measurement precision.

Operating as an IP-Link extension module, this device integrates seamlessly with Beckhoff Coupler Box modules, transferring digitized process data over high-speed IP-Link communication channels. The robust housing, high-resolution digitization, and configurable filtering capabilities make it an ideal choice for challenging distributed control architectures.

Features

  • Four independent analog inputs dedicated to RTD and resistance measurements.
  • Flexible M12 screw-type connections supporting 2-, 3-, and 4-wire configurations.
  • Compatible with a comprehensive range of platinum (Pt) and nickel (Ni) sensors.
  • High-resolution data acquisition at 0.1 degC per digit for sensitive thermal monitoring.
  • Configurable conversion times ranging from a standard 250 ms down to 65 ms.
  • Five configurable digital input filter variations for advanced noise rejection.
  • IP-Link interface for fast, reliable data exchange with fieldbus couplers.
  • Heavy-duty IP65/66/67 protection rating for direct mounting in harsh industrial zones.

Applications

  • Decentralized process temperature tracking in plant engineering and machine construction.
  • Thermal monitoring of motors, bearings, and critical mechanical assemblies.
  • Food processing and washdown-heavy environments requiring direct-to-machine installation.
  • HVAC, chemical processing, and environmental monitoring systems.

Technical Specifications

ManufacturerPart Number / ModelNumber of InputsConnection MethodSensor TypesMeasuring RangeResolutionMeasurement Error / UncertaintyConversion TimeNominal VoltageMeasuring CurrentInput FilterSensor SupplyCurrent Consumption from USPower Supply ConnectionBit Width in Process ImageElectrical IsolationOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection RatingInstallation PositionWeight
BECKHOFF
IE3202
4
Screw-type M12 for 2-, 3-, and 4-wire connections (preset: 4-wire)
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g., potentiometer)
-250 to +850 degC (Pt sensors); -60 to +250 degC (Ni sensors)
0.1 degC per digit
less than ±1 degC
Approx. 250 ms, configurable down to 65 ms
24 V DC (-15 % / +20 %)
typ. 0.5 mA
5 variations, configurable
Derived from control voltage US
40 mA (excluding sensor current)
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Input: 4 x 16-bit data (4 x 8-bit control/status optional)
Channels/control voltage: 500 V; Between channels: None; Control voltage/fieldbus: Yes, via IP-Link
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65/66/67 (conforms to EN 60529)
Variable
2.0 kg

Connections and Interfaces

Power FeedPower DownstreamAnalog Inputs 1 - 4
Connection Point Connector Type Functional Assignment
M8 Male, 4-pin Control voltage US input
M8 Female, 4-pin Loop-through control voltage US to subsequent modules
M12 Female, 5-pin RTD sensor connection (supporting 2-, 3-, or 4-wire layouts)

Installation Guidelines

  • Mounting: Mount the unit directly onto a flat, vibration-resistant surface using appropriate fastening screws. Ensure sufficient clearance for connecting and disconnecting cables.
  • Shielding & Grounding: To minimize electromagnetic interference, use shielded sensor cables. Connect the cable shields to the metal M12 connector housings wherever possible.
  • Environmental Protection: To maintain the IP65/66/67 seal, tighten all M12 and M8 connectors to their specified torque limits. Seal any unused connection ports with industrial-grade protective caps.
  • Cabling: Maintain separation between sensor input lines and high-power AC power cables or variable frequency drive outputs to prevent noise coupling.

Compliance and Certifications

  • CE: European Conformity
  • UL: Underwriters Laboratories Listed
Loading product navigation…

Which temperature sensor types are compatible with the Beckhoff IE3202?

The IE3202 is compatible with several RTD types, including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, and Ni1000. It also supports general resistance and potentiometer measurements.

Does the IE3202 support 3-wire RTD configurations?

Yes, the M12 screw-type terminals can be wired for 2-wire, 3-wire, or 4-wire sensors. The device is preset for 4-wire operation out of the box.

What is the ingress protection rating of the IE3202 Fieldbus Box?

It is rated at IP65, IP66, and IP67, making it dust-tight and highly resistant to water jets and temporary submersion. This allows direct installation on machines without control cabinets.

How does the IE3202 transfer its measurement data to the main PLC system?

The IE3202 acts as an extension module that connects to a master Fieldbus Box (Coupler Box) via the high-speed fiber-optic IP-Link interface, which then bridges the data to the main fieldbus protocol.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...