1 dari 1

Beckhoff IL2302-B528 Fieldbus Box DeviceNet Coupler Box

Beckhoff IL2302-B528 Fieldbus Box DeviceNet Coupler Box

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IL2302-B528

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Coupler Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for decentralized field automation in demanding industrial environments, the Beckhoff IL2302-B528 acts as a robust DeviceNet communication adapter within the IP67-rated Fieldbus Box system. This modular coupler box enables the direct connection of up to 120 extension modules, managing a maximum data capacity of 512 bytes of input and 512 bytes of output data. By housing fieldbus components in a rugged, moisture-resistant enclosure, the Beckhoff IL2302-B528 eliminates the need for protective control cabinets, reducing cabling complexity and minimizing installation footprints on the factory floor.

Key Features

  • DeviceNet Connectivity: Integrates an onboard 5-pin M12 plug and socket interface with an integrated T-connector for direct bus looping.
  • Extensive I/O Expansion: Supports up to 960 digital inputs/outputs or up to 252 analog inputs/outputs across downstream extension blocks.
  • Flexible Configuration: Parametrization and commissioning are quickly managed via KS2000 software interface or explicit messaging from the master controller.
  • Automated Baud Rate Detection: Automatically identifies and synchronizes with DeviceNet network transfer speeds up to 500 kbaud.
  • High Environmental Resistance: IP65, IP66, and IP67 certified protection, making it ideal for wet, dusty, or high-vibration machinery layouts.

Industrial Applications

  • Automotive Assembly Lines: Direct mounting on robotic arms and transport fixtures without protective enclosures.
  • Packaging and Food Processing: Resists washdown routines and localized environmental exposure.
  • Material Handling and Logistics: Distributed I/O setups along widespread conveyor networks.

Technical Specifications

Manufacturer Beckhoff
Model / Order Code IL2302-B528
Fieldbus System DeviceNet
Extension Modules Max. 120 (Max. 512 bytes input / 512 bytes output)
Data Transfer Rates Automatic baud rate detection up to 500 kbaud
Power Supply 24 V DC (-15% / +20%)
Current Consumption (Box Supply) 45 mA + current consumption of sensors (Max. 0.5 A)
Electrical Isolation 500 V (Control voltage / fieldbus)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Approvals CE, UL
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Interface Type Connection Details
DeviceNet Fieldbus 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated loop-through tee-connector
Power Supply Input 1 x M8 male socket, 4-pin (Feed)
Downstream Power 1 x M8 female socket, 4-pin (Daisy-chain feed to next module)

Alternative Models & Compatibility

The IL2302-B528 forms part of the legacy IP67 Fieldbus Box range. When migrating systems or planning maintenance, verify that replacement units match the exact -B528 DeviceNet sub-protocol firmware specifications. Note that while EtherCAT-based modules (such as EP-series) are preferred for modern EtherCAT topologies, the IL2302-B528 remains critical for sustaining legacy DeviceNet architectures and Allen-Bradley scanner networks without re-engineering the PLC code.

Application Pitfalls & Engineering Notes

The internal logic of the IL2302-B528 draws 45 mA from the 24 V DC control voltage line, but cumulative sensor currents can quickly exceed the 0.5 A local module threshold. In systems with long IP67 extension cascades, verify the voltage drop across the M8 feed cables. Standard M8 distribution links drop voltage over distance; always install auxiliary power feed-in points if the calculated run drops below 20.4 V DC at the farthest extension node.

Commissioning & Wiring Tips

When configuring the DeviceNet trunk, ensure the correct baud rate matching. The IL2302-B528 auto-detects network speeds, but requires a stable fieldbus signal to execute lock-on. Ensure proper 121-ohm termination resistors are installed on both ends of the DeviceNet physical trunk. When utilizing the KS2000 configuration interface, utilize standard Beckhoff serial diagnostic cables (KS2000-Z2) connected directly to the programming port for configuration without network load.

Installation Guidelines

CRITICAL WARNING: Prior to mounting, commissioning, or servicing the IL2302-B528, isolate all power sources supplying the module, fieldbus network, and extension loops. Touching energized pins, particularly in wet environments, can trigger short circuits, corrupt communication lines, and cause localized hardware failure.
1

Mount the Fieldbus Box using M3 or M4 screws onto a flat, vibration-resistant surface. Avoid uneven mechanical stress to prevent damage to the sealed IP67 joints.

2

Connect the DeviceNet trunk lines to the integrated M12 connectors. Fully hand-tighten the coupling rings to secure the IP67 environmental seal.

3

Route the 24 V DC control voltage through the M8 inlet. Ensure matching polarity and secure the downstream daisy-chain links to consecutive modules.

Loading product navigation…

What is the maximum distance supported between stations using the IL2302-B528?

The maximum transmission distance depends on the DeviceNet configuration and selected baud rate: up to 500 meters at 125 kbaud, 250 meters at 250 kbaud, and 100 meters at 500 kbaud.

How is the DeviceNet node address (MAC ID) configured on this module?

The MAC ID and communication parameters can be mapped dynamically using the KS2000 software suite or parametrized directly from the master controller via explicit messaging over the DeviceNet network.

Does the IL2302-B528 require an external power supply for the connected sensors?

Yes. While the coupler box's internal logic consumes 45 mA, sensor power is drawn from the 24 V DC feed through the M8 connector, supporting a total current passage of up to 0.5 A.

What happens if the current load of the extension sensors exceeds 0.5 A?

Exceeding the 0.5 A threshold can cause thermal overload or communication drops. You must integrate auxiliary power feed modules upstream to distribute current loads correctly.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...