1 dari 1

BECKHOFF IP1012-B518 Fieldbus Box 8-Channel Digital Input Module

BECKHOFF IP1012-B518 Fieldbus Box 8-Channel Digital Input Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IP1012-B518

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Boxes

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 30 mm x 210 mm x 26.5 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for decentralized automation setups without control cabinets, the IP1012-B518 is an 8-channel digital input module integrated into a robust CANopen Fieldbus Box housing. This module allows the direct acquisition of up to eight binary control signals from sensors and transducers operating in demanding industrial environments. Equipped with an integrated M12 T-connector, it simplifies fieldbus line routing by facilitating direct looping of the CANopen bus without requiring external splitters or distribution blocks.

With an extremely fast input filter of 0.2 ms, this CANopen Fieldbus Box ensures high-speed signal capture and optimal dynamic performance. It operates with a nominal 24 V DC supply and is sealed within a high-grade polyamide housing, achieving IP65/66/67 ingress protection. The device is optimized for mounting directly onto machines, significantly reducing wiring overhead and cabling costs in complex plant configurations.

Features

  • Eight independent digital input channels for binary sensor signals.
  • Integrated CANopen bus interface with a built-in T-connector (1 x M12 plug, 5-pin and 1 x M12 socket, 5-pin).
  • Rapid input filter time of 0.2 ms for time-critical automation applications.
  • Robust, fully sealed PA6 (polyamide) XXL housing suited for harsh industrial environments.
  • M12 connection technology for digital inputs to ensure reliable, secure cabling.
  • M8 connectors for downstream power feed-through to adjacent modules.
  • Diagnostic and status LEDs for rapid visual fault isolation on-site.

Applications

  • De-centralized machinery control and assembly systems.
  • Material handling, packaging, and sorting conveyor systems.
  • Automotive manufacturing and robotic assembly lines.
  • Process plants requiring direct, field-level sensor integration without terminal enclosures.

Technical Specifications

System & Communication Specifications
Manufacturer BECKHOFF
Model / Part Number IP1012-B518
Fieldbus Protocol CANopen
Data Transfer Rates 10 kbaud to 1 Mbaud (automatic detection)
I/O Communication Types Event-driven, cyclic, synchronous, polling
Number of PDOs 16 send and 16 receive process data objects
Max. Stations (CANopen) 63 (up to 99 with repeaters)
Digital Input Parameters
Number of Inputs 8
Input Connection Type M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 0.2 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 2)
Input Current typ. 6 mA (EN 61131-2, type 2)
Sensor Supply From control voltage, max. 0.5 A total (short-circuit proof)
Electrical & Mechanical Data
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Connections Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Box Supply Current 45 mA + sensor current (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Housing Material PA6 (Polyamide)
Shipping Weight 2.0 kg
Environmental & Operating Limits
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Vibration & Shock Immunity Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Emission & Immunity Conforms to EN 61000-6-4 and EN 61000-6-2

Connections and Interfaces

Interface Port Connector Type Function Description
CANopen In 1 x M12 plug, 5-pin Primary CAN bus network input connection
CANopen Out 1 x M12 socket, 5-pin Downstream loop connection via integrated T-connector
Power Input 1 x M8 male, 4-pin 24 V DC control voltage input feed
Power Output 1 x M8 female, 4-pin Power distribution connection for adjacent modules
Digital Inputs M12 screw sockets Direct connection for up to 8 field sensors

Installation Guidelines

  • Mounting: Mount the unit directly to the machine frame using the two 3.5 mm diameter fixing holes designed for M3 screws. Ensure a flat surface to prevent mechanical stress on the PA6 housing.
  • Grounding: Guarantee proper functional grounding to secure high EMC immunity in noisy environments.
  • Cable Routing: Keep high-voltage cables separated from the CANopen and M12 sensor cables to prevent electromagnetic interference.
  • IP Rating Integrity: Use IP67-rated mating connectors and protective caps on all unused M12 and M8 ports to maintain the unit’s environmental sealing integrity.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the primary function of the Beckhoff IP1012-B518?

The IP1012-B518 is an 8-channel digital input Fieldbus Box designed to acquire binary sensor signals in the field and transmit them over a CANopen network.

Does the IP1012-B518 require a separate CANopen T-connector?

No, it features an integrated T-connector (comprising one M12 plug and one M12 socket) that allows direct loop-through configuration of the CANopen bus line.

What is the input filter speed of this module?

The digital inputs feature a rapid 0.2 ms filter time, making it ideal for high-speed signal capture.

Can this module be installed without a control cabinet?

Yes, its polyamide housing has an IP65/66/67 rating, which enables direct mounting on machines in dusty or wet environments.

What type of connector is used for power supply routing?

The module uses standard 4-pin M8 connectors: a male socket for the incoming power feed and a female socket for downstream power forwarding.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...