Beckhoff IP2302-B800 Fieldbus Box

Beckhoff IP2302-B800 Fieldbus Box

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IP2302-B800

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Decentralized operational architectures benefit from the robust physical and electrical design of the Beckhoff IP2302-B800 fieldbus interface unit. This system integrates high-density digital I/O capabilities directly at the machine level, eliminating the need for expensive electrical enclosures. Operating via an RS485 interface, this module enables reliable serial communications across extended distances in high-noise industrial environments. With 4 digital inputs featuring a 3 ms input filter and 4 digital outputs delivering up to 0.5 A per channel, the unit provides a balanced local control solution for sensors and actuators utilizing standard M12 connection technology.

Features

  • Dual-Directional I/O Configuration: Equipped with 4 digital inputs and 4 digital outputs to manage local field sensors and actuators from a single station.
  • Serial Communication Interface: Integrated RS485 physical layer provides stable data transmission over long physical distances in high-interference settings.
  • Optimized Input Filtering: Input hardware includes a 3 ms hardware filter to prevent false triggers from mechanical switch bounce and electrical noise.
  • Short-Circuit Protected Outputs: High-side 24 V DC outputs deliver up to 0.5 A of continuous current, protected against overload and thermal faults.
  • Robust IP67 Protection: Fully sealed enclosure designed to withstand moisture, dust, and direct liquid washdowns without secondary protective housings.

Applications

  • Automotive Assembly Lines: Direct mounting on mechanical structures for localized proximity sensor and pneumatic valve routing.
  • Conveyor and Material Handling Systems: Direct control of sorters, divert gates, and photo-eye sensors over long RS485 bus runs.
  • Packaging Machinery: Compact field deployment on rotary indexes and fast-moving indexing tables where cabinet space is unavailable.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Reference IP2302-B800
Fieldbus Interface RS485
Digital Inputs 4 channels (24 V DC)
Input Filter Time 3 ms
Digital Outputs 4 channels (24 V DC, short-circuit protected)
Max. Output Current 0.5 A per channel
I/O Connection Method M12 connector (screw-type lock)
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Protection Class IP67 (when all unused ports are sealed)
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg (including protective packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2302-B800 belongs to the legacy Beckhoff Fieldbus Box architecture. When integrating this module into newer EtherCAT networks, a gateway or a corresponding coupler (such as the EP-series Fieldbus Boxes) should be selected unless native RS485 communication interfaces are already established in your PLC control system. Note that firmware addressing parameters are set via physical rotary switches on the side of the housing; preserve these settings when swapping old hardware for new replacements.

Application Pitfalls & Engineering Notes

While the outputs are rated for 0.5 A individually, engineers must calculate the total aggregate load current flowing through the control box. Exceeding the internal thermal limitations will trip the integrated thermal shutdown mechanisms. Additionally, when long RS485 cable runs are deployed alongside high-voltage motor cables, induced transient voltages can corrupt serial frame packets. Maintaining physical separation of signal and power lines is critical.

Commissioning & Wiring Tips

For RS485 communication stability, ensure that a 120-Ohm termination resistor is physically installed at the absolute start and end points of the communication segment. Always use shielded, twisted-pair cabling specifically certified for RS485 network protocols. Ground the shield at a single central point to prevent circulating ground loops that can degrade signal integrity.

Installation Guidelines

CRITICAL WARNING: Prior to attempting hardware installation, commissioning, or physical swap-outs, ensure all auxiliary power supplies (both the logic control power and actuator output load power lines) are completely de-energized. Confirm that zero voltage is present across all terminal lines to prevent damage to the sensitive serial communication driver circuitry.
1
Mechanical Mounting: Mount the Fieldbus Box securely onto a flat, vibration-dampened structural surface using two M4 bolts. Ensure the mounting plane is even to prevent physical stress on the housing.
2
Configure Network Node Address: Set the unique node address using the hardware rotary coding switches under the protective screw cap. Secure the protective cap tightly after configuration to maintain the IP67 ingress seal.
3
Fieldbus Connection: Route and secure the RS485 communication line to the designated M12 fieldbus connector port. Hand-tighten the M12 screw rings to ensure a fully dust- and water-tight interface.
4
Power & I/O Cabling: Connect the 24 V DC supply and individual local sensors/actuators. Seal all unused M12 ports with industrial-grade protective caps to prevent environmental contamination and moisture ingress.
Loading product navigation…

What is the function of the RS485 interface on this module?

The RS485 interface acts as the physical layer for serial communication, permitting data exchange between the PLC and the decentralized I/O module over extended cable runs in electrically noisy environments.

How is the IP67 protection class rating preserved on the factory floor?

The IP67 rating is only maintained if all M12 ports are fully tightened and all unused sensor/actuator ports are fitted with sealed industrial protective plastic or metal caps.

Can the digital outputs on the IP2302-B800 drive inductive loads?

Yes, the 0.5 A digital outputs can drive inductive loads, but it is highly recommended to install external flyback diodes across the inductive coils to eliminate voltage spikes during de-energization.

What is the purpose of the 3 ms input filter on the digital inputs?

The 3 ms hardware input filter debounces signals from physical proximity switches or mechanical contacts, ensuring that only true transitions are reported to the controller.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...