1 dari 1

Beckhoff IP2310-B310 Fieldbus Box 4-Channel Input/Output Module

Beckhoff IP2310-B310 Fieldbus Box 4-Channel Input/Output Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IP2310-B310

  • Negara asal:Jerman

  • Jenis Produk: Distributed I/O Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Decentralized signal acquisition on the factory floor is handled efficiently by the Beckhoff IP2310-B310 Fieldbus Box. This robust distributed I/O module integrates 4 digital inputs and 4 digital outputs directly into a high-speed PROFIBUS DP network without requiring an IP20 protective enclosure. Designed for direct machine-mounting, the device processes rapid digital signals with a 0.2 ms filter constant while offering high protection against environmental moisture and particulates. The Beckhoff IP2310-B310 enables engineers to minimize control cabinet space and drastically reduce field-level wiring complexity by mounting the control interfaces directly on the mechanical structure.

Features

  • PROFIBUS DP Interface: High-performance fieldbus coupling with automatic baud rate detection up to 12 Mbaud.
  • Optimized I/O Density: Configured with 4 digital inputs (24 V DC) and 4 digital outputs (24 V DC, 0.5 A short-circuit protected).
  • Direct Machine Integration: IP67-rated enclosure protects internal components against water jets, dust, and particulate contamination.
  • Compact M8 Connections: Direct physical linkage for industrial sensors and actuators utilizing compact M8 (dia 8 mm) circular plug connectors.
  • Status Diagnostics: Dedicated LED indicators showing fieldbus status, power supply status, and individual channel activity.

Applications

  • Automotive assembly lines and robotic welding cells requiring decentralized tool-tip logic.
  • Conveyor and material handling networks with widely distributed proximity sensors and pneumatic solenoids.
  • Food processing and packaging machines exposed to frequent washdown procedures.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Code IP2310-B310
Fieldbus System PROFIBUS DP
Digital Inputs 4 x 24 V DC (Filter: 0.2 ms)
Digital Outputs 4 x 24 V DC (0.5 A per channel, short-circuit proof)
Control Voltage 24 V DC (-15% / +20%)
Sensor Supply Current Max. 0.5 A sum total for all sensors
I/O Connection Method M8 (dia 8 mm) screw-lock / snap-in connectors
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Protection Class IP67
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

M8 Connector Pin Input Port Function Output Port Function
Pin 1 +24 V DC Sensor Supply Not Connected / Reserve
Pin 3 GND (0 V) GND (0 V)
Pin 4 Input Signal (Ch 1 - 4) Output Signal (Ch 1 - 4)

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems, note that the IP2310-B310 uses the PROFIBUS DP standard protocol and relies on specific GSD files (typically I2310B31.gsd) during PLC hardware configuration. If replacing this module with newer EtherCAT-based options like the EP2318-0001, complete changes to the master controller configuration and physical cabling infrastructure are mandatory.

Application Pitfalls & Engineering Notes

Although the output channels are short-circuit protected and rated for 0.5 A each, the total combined current of the module's sensor supplies must not exceed 0.5 A. Deploying multiple high-draw photo-eye sensors without supplementary external distribution blocks will trip the internal thermal fuses. Ensure inductive load suppression (e.g., flyback diodes) is integrated externally when driving high-inductance pneumatic solenoids to prevent premature degradation of the solid-state output circuitry.

Commissioning & Wiring Tips

For robust PROFIBUS communication at rates exceeding 1.5 Mbaud, ensure that both physical ends of the PROFIBUS segment are properly terminated with active 220-ohm pull-up termination resistors. Keep the standard M8 sensor lines under 3 meters to prevent inductive coupling and high-frequency noise interference from adjacent variable frequency drive (VFD) cables.

Installation Guidelines

CRITICAL SAFETY WARNING

Before starting physical mounting, wiring, or maintenance on the PROFIBUS network, isolate all electrical power supplies. Disconnect both the control power (Us) and peripheral load power (Up) channels. Failure to de-energize can lead to accidental actuator actuation or severe communication dropouts due to transient ground loops.

1

Position the module flat against a clean, vibration-resistant machine frame structure. Securely tighten both mounting screws (M4 size) using an appropriate torque limit of 1.2 Nm to guarantee mechanical grounding.

2

Connect the incoming PROFIBUS and local power distribution cabling. Verify that all unused M12 and M8 connector sockets are sealed with official IP67 protective caps to keep out environmental moisture.

3

Adjust the rotary hardware address switches on the front face of the module to align exactly with the assigned node address configured inside your central PLC hardware configuration tool.

Loading product navigation…

What standard GSD configuration file is needed for the IP2310-B310?

This module uses the standard Beckhoff PROFIBUS DP GSD database file, typically named I2310B31.gsd, which allows integration into STEP 7, TIA Portal, or TwinCAT configurations.

How are the sensor power supply limits structured on this module?

The total cumulative current drawn by all connected sensors on the 4 inputs must not exceed 0.5 A. Exceeding this limit triggers internal self-resetting protection circuits.

Can the digital outputs drive inductive loads such as solenoid valves?

Yes, the solid-state outputs are rated up to 0.5 A. However, for highly inductive loads, external freewheeling suppression diodes must be placed across the load to block inductive back-EMF.

What physical connector styles are used for the fieldbus and the I/O?

The digital I/O channels interface via M8 (dia 8 mm) circular connectors. The PROFIBUS DP interface is terminated via standard fieldbus M12 or 9-pin connections depending on the exact box subtype configuration.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...