BECKHOFF IP5109-B318 Fieldbus Box Module

BECKHOFF IP5109-B318 Fieldbus Box Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: IP5109-B318

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Boxes

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Decentralized signal processing in harsh industrial environments requires robust, field-mountable input/output modules that eliminate the need for protective control cabinets. The IP5109-B318 Fieldbus Box provides a direct connection to PROFIBUS DP networks, permitting reliable high-speed data transmission directly on the machinery. Designed with integrated M12 bus interfaces and M8 power connections, this module enables rapid installation and seamless integration into existing control architectures. Configuration of the device can be executed directly through the master controller or via the specialized KS2000 software suite, which fully supports DP-V1 extensions for parameterized operation.

Features

  • Automatic Baud Rate Detection: Automatically adjusts and synchronizes to network transfer speeds up to 12 Mbaud.
  • Integrated T-Connector: Features a dual M12 interface (plug and socket) minimizing additional network cabling and external splitting hardware.
  • Rugged Environmental Protection: IP65, IP66, and IP67 ingress protection ratings allow mounting directly on equipment without an enclosure.
  • Flexible Parameterization: Supports standard DP-V1 acyclic communication and configuration through KS2000.
  • Power Pass-Through: M8 power connectors allow daisy-chaining control and load voltages to downstream modules, reducing wiring complexity.

Applications

  • Automotive assembly lines and conveyor systems
  • Material handling and sorting systems
  • Food processing and packaging machinery
  • Wastewater treatment facility distributed automation

Technical Specifications

Manufacturer BECKHOFF
Part Number IP5109-B318
Protocol / Fieldbus PROFIBUS DP, DP-V1
Data Transfer Rates Up to 12 Mbaud (automatic detection)
Bus Interface Connection 1 x M12 socket (5-pin, B-coded), 1 x M12 plug (5-pin, B-coded, integrated T-connector)
Data Transfer Medium Shielded copper cable, 2 x 0.25 square millimeters
Control Voltage Power Supply 24 V DC (-15% / +20%)
Load Voltage Power Supply Determined by I/O type
Power Connections Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current Consumption 85 mA + sensor current consumption (maximum 0.5 A)
Electrical Isolation Control voltage/fieldbus: No; Control voltage/inputs-outputs: Dependent on I/O type
Data Transfer Cycle Time Approximately 0.5 ms with 10 stations (each 32-bit input/output)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Shipping Weight 2.0 kg

Connections and Interfaces

Interface Type Connector Style Pin Count & Coding
Fieldbus Input (Bus In) M12 Plug 5-pin, B-coded
Fieldbus Output (Bus Out) M12 Socket 5-pin, B-coded (integrated tee)
Power Supply Feed M8 Male 4-pin
Power Supply Downstream M8 Female 4-pin

Installation Guidelines

Ensure that the mounting surface is clean and flat to maintain the unit's ingress protection. Secure the module using the integrated mounting holes. When routing cables, avoid sharp bends and keep signal cables separate from high-power load lines to prevent electromagnetic interference. All unused M12 and M8 connection ports must be sealed using certified protective caps to maintain the IP65/66/67 environmental rating. Properly ground the fieldbus shield according to standard Profibus installation recommendations.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What configuration tools are compatible with the IP5109-B318?

The module can be configured directly through your primary master controller or using Beckhoff's KS2000 configuration software via the DP-V1 extensions.

Does the IP5109-B318 require a separate Profibus T-connector?

No, the module features an integrated T-connector design using one B-coded M12 socket and one B-coded M12 plug, allowing direct loop-through of the fieldbus line.

How do you maintain the IP67 protection rating when some ports are unused?

To preserve the IP65/66/67 rating, all unused M12 and M8 connector sockets must be fitted with certified protective screw caps.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...