Industrial processing systems utilize the BECKHOFF KS3444 analog input bus terminal to interface standard 0 to 20 mA signals directly from the field level to the higher-level automation controller. This four-channel module features single-ended inputs and provides a highly space-efficient design with a pluggable wiring level, enabling fast, tool-free installation and maintenance. By operating directly through the standard K-bus, the unit transmits digitized process values back to the coupler or controller with a 12-bit resolution. Integrated electrical isolation of 500 V between the K-bus and the signal channels guarantees high noise immunity and signal integrity in demanding electrical environments.

Features

  • Four single-ended analog inputs handling standard 0 to 20 mA current loops.
  • Pluggable connection level (KS-series design) allowing pre-wiring and rapid terminal replacement.
  • Compact 12 mm housing width to optimize control cabinet and DIN rail space.
  • K-bus powered with a typical current consumption of 85 mA.
  • Reliable performance across a broad operating temperature range of 0 to +55 degC.
  • Sturdy design complying with EN 60068-2-6 and EN 60068-2-27 for vibration and shock resistance.

Applications

  • Chemical and petrochemical processing plants.
  • Water and wastewater treatment facilities.
  • Machinery manufacturing and factory automation.
  • HVAC and building automation controls.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer BECKHOFF KS3444
Product Type Bus Terminal (Pluggable wiring level) 4
Signal Current 0 to 20 mA Single-ended
Internal Resistance < 85 Ohm 12 bit
Conversion Time approx. 2 ms < ±0.3 % (relative to full scale value)
Surge Voltage Resistance 30 V DC 500 V (K-bus/signal voltage)
Current Consumption K-Bus typ. 85 mA Input: 4 x 16 bit data (4 x 8 bit control/status optional)
Housing Material Polycarbonate IP20 / variable
Operating Temperature 0 to +55 degC -25 to +85 degC
Relative Humidity 95 %, non-condensing Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4 35 mm DIN rail (EN 60715) with lock
Connection Cross-section Solid/Stranded: 0.08 to 1.5 mm²; Fine-wire: 0.14 to 1.5 mm² AWG 28 to 16 (Solid/Stranded); AWG 26 to 16 (Fine-wire)
Stripping Length 9 to 10 mm 12 mm x 100 mm x 68 mm
Weight 0.055 kg II 3 G Ex nA IIC T4 Gc

Connections and Interfaces

Connection Point Signal Assignment
Terminal 1 Input 1 (+)
Terminal 2 Input 2 (+)
Terminal 3 Input 3 (+)
Terminal 4 Input 4 (+)
Terminal 5 Input 1 (0 V)
Terminal 6 Input 2 (0 V)
Terminal 7 Input 3 (0 V)
Terminal 8 Input 4 (0 V)

Installation Guidelines

  • Mount the terminal on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking mechanism is securely engaged.
  • To wire the pluggable KS terminal, use a flat-bladed screwdriver to actuate the integrated tension clamp mechanism.
  • Ensure the system power supply is deactivated before plugging or unplugging the terminal wiring block to prevent damage to the K-bus connections.
  • Observe regional grounding and shielding guidelines for analog signal cables to minimize electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX (II 3 G Ex nA IIC T4 Gc)
  • DNVGL
Loading product navigation…

What is the primary difference between the Beckhoff KL3444 and the KS3444?

The KS3444 features a pluggable wiring level, allowing the terminal block connector to be detached from the main housing without disconnecting individual field wires. The KL3444 has a fixed wiring level.

Does the KS3444 require an external power supply for K-bus communication?

No, the KS3444 is powered directly via the K-bus backplane from the bus coupler or controller, drawing a typical current of 85 mA.

Is the Beckhoff KS3444 suitable for hazardous locations?

Yes, the KS3444 is ATEX certified with Ex marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas when installed in an appropriate enclosure.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...