1 dari 1

Beckhoff ZB7210-0100 EtherCAT P Drag-Chain Cable

Beckhoff ZB7210-0100 EtherCAT P Drag-Chain Cable

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: ZB7210-0100

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT P Cables

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 1 x 4 x 0.34 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for demanding dynamic industrial environments, the Beckhoff ZB7210-0100 raw cable integrates high-speed EtherCAT P communication and robust auxiliary power distribution within a single wear-resistant sheath. This cable features a high-flexibility construction tailored specifically for continuous motion in drag chains and moving machine elements. By combining four Ethernet communication cores with three high-capacity power conductors, it eliminates the need for separate signal and power lines, reducing installation footprint, labor costs, and cable carrier weight in decentralized control architectures.

Features

  • Optimized for Motion: Engineered specifically for drag-chain routing with reliable torsion and bending endurance.
  • Rugged PUR Sheath: Polyurethane (PUR) outer jacket provides exceptional resistance to mineral oils, synthetic coolants, and mechanical abrasion.
  • High-Visibility Identification: Deep black jacket (similar to RAL 9005) with a distinctive red stripe (similar to RAL 3020) for instantaneous identification as an EtherCAT P line.
  • Dual-Function Core Design: Integrates a 4-core Ethernet star quad with three large-cross-section power conductors to service standard 24V DC logic and peripheral power.

Applications

  • Decentralized I/O stations utilizing Beckhoff EtherCAT P EP-series box modules.
  • Multi-axis robotic arms, gantries, and automated pick-and-place machinery.
  • Dynamic material handling, continuous-flex packaging lines, and conveyor tracking systems.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model/Article Number ZB7210-0100
Cable Type EtherCAT P (Combined communication & power)
Overall Shielding No overall shield
Ethernet Cross Section 1 x 4 x 0.34 mm2 (AWG 22)
Power Cross Section 3 x 2.5 mm2 (approx. AWG 14)
Jacket Material PUR (Polyurethane)
Outer Cable Diameter 11.1 mm (+/- 0.2 mm)
Jacket Color Black (RAL 9005) with red stripe (RAL 3020)
Mechanical Use Case Drag-chain suitable / Continuous flexing
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Conductor Group Wire Properties Primary Function
Ethernet Core (Star Quad) 4 x 0.34 mm2 (AWG 22) EtherCAT P signal transmission (Tx+/Rx+/Tx-/Rx-) with integrated 24V supply on signal lines (Us/Up)
Power Core 3 x 2.5 mm2 (AWG 14) Auxiliary power lines for peripheral loads, actuators, and high-current hardware branches

Empirical Engineering Insights

Alternative Models & Compatibility

The ZB7210-0100 is supplied as raw bulk cable. It is fully compatible with standard Beckhoff B23 field-installable connectors. When selecting connectors, ensure you source B23 Series EtherCAT P rated connectors to maintain correct spacing and pin alignment for the AWG 14 power and AWG 22 communication lines. Do not use standard EtherCAT (non-P) connectors, as standard EtherCAT does not support integrated power lines on the communication cores.

Application Pitfalls & Engineering Notes

While the outer PUR jacket is exceptionally tough, avoid exceeding the maximum physical bending limits inside a drag chain. Torsional stress should be eliminated by ensuring the cable is laid flat without twists when first wound into the carrier. Running this cable adjacent to unshielded high-voltage AC motor drives in the same tray should be done with care; although the EtherCAT signal is highly robust, physical separation from noisy motor leads prevents coupling into the unshielded power conductors inside this cable run.

Commissioning & Wiring Tips

When stripping the outer jacket to terminate into a field-mountable connector, use specialized outer jacket strip tools calibrated for 11.1 mm outer diameters to prevent nicking the thin insulation on the 0.34 mm2 communication cores. Ensure that the red identification stripe remains visible outside the cable gland of your connector to allow field technicians to distinguish the safe EtherCAT P network run from standard Ethernet lines at a glance.

Installation Guidelines

CRITICAL WARNING: Prior to terminating, pulling, or adjusting cables, verify that all power sources supplying both communication (Us) and peripheral (Up) networks are fully de-energized. Do not plug or unplug the terminations of this cable under load, as arcing can damage internal contacts and delicate downstream PLC electronics.
1

Unroll the cable directly from the drum before installation. Do not pull the cable over the side of the spool, as this introduces structural twisting that degrades drag-chain life expectancy.

2

Lay the cable loosely in the drag chain. Ensure it occupies no more than 60 percent of the internal cross-section of the carrier cavity to allow lateral movement during high-flexion runs.

3

Secure both ends of the cable with robust strain relief brackets outside the moving sections of the drag chain. Clamp only the outer PUR jacket without compressing the internal cores.

Loading product navigation…

What is the mechanical advantage of the PUR jacket on this cable?

The Polyurethane (PUR) jacket offers high resistance to oil, abrasion, tearing, and micro-organisms, making it excellent for continuous dynamic flexing in industrial drag-chain applications.

Does this cable have an overall shield?

No, this specific configuration has no overall shield surrounding all the internal conductors, which increases flexibility and reduces weight for designated motion paths.

What is the difference between standard EtherCAT and EtherCAT P cabling?

EtherCAT P combines EtherCAT industrial communication and system/field power (Us and Up) into a single physical cable, distinguished by its black jacket with a red stripe.

Can I terminate this cable with standard RJ45 connectors?

No, because the cable contains large 2.5 mm2 power conductors, standard RJ45 connectors are physically incompatible. You must use specialized EtherCAT P connectors such as the B23 series.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...