1 dari 3

Bently Nevada 140482-01 3500/42M Prox/Velom I/O Module with External Terminations

Bently Nevada 140482-01 3500/42M Prox/Velom I/O Module with External Terminations

Hanya 4 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 140482-01

  • Negara asal:Amerika Serikat

  • Jenis Produk: I/O Modules

  • Kode batang: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 200g

  • Dimensi: 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

The Bently Nevada 140482-01 is a Prox/Velom I/O module with external terminations designed for signal interfacing between transducers and the 3500/42M Proximitor Seismic Monitor or 3500/72M Recip Rod Position Monitor. The module routes input signals from Proximitor, accelerometer, Velomitor, or HTVS transducers located in the field through the rear slot of a 3500 system rack directly into the main monitor board. It conditions incoming signals and delivers power supply outputs while maintaining signal integrity for 4-channel vibration and position monitoring operations.

Features

  • Accepts inputs from Proximitor, accelerometer, Velomitor, or HTVS transducers
  • External termination interface design for off-rack field wiring connection
  • Supports multi-channel signal routing to the 3500/42M and 3500/72M monitor main boards
  • Occupies 1 full-height rear slot in the 3500 system rack

Applications

  • Machinery protection and condition monitoring
  • Hydro-turbines, gas turbines, and steam turbines
  • Reciprocating compressor rod position and drop monitoring
  • Industrial pumps, fans, and motor assemblies

Ordering Information

Part / Option Description
140482-01 Prox/Velom I/O Module with External Terminations
125808-08 Proximitor / Velomitor External Termination Block (Euro Style Connectors)
128015-08 Proximitor / Velomitor External Termination Block (Terminal Strip Connectors)
129525-AAAA-BB 3500 Transducer XDCR signal to External Termination Block Cable
00561941 3500/42M Prox/Velom I/O Module 10-pin connector shunt

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (a Baker Hughes Company)
Model 140482-01
Module Type Prox/Velom I/O Module with External Terminations
Compatible Transducers Prox/Accel, Velomitor, HTVS
Supply Parameters (Prox/Accel) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Supply Parameters (Velomitor) U = 23.9 V, I = 45.5 mA, P = 1.09 W
Rack Space Requirement 1 full-height rear slot
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight 0.20 kg (0.44 lb)

Installation Guidelines

  • Install the module into 1 full-height rear slot corresponding to the associated front monitor module in the 3500 rack.
  • Connect the external termination block to the rear module using the designated 129525 external termination cable.
  • Ensure proper field wiring connection on the external termination block with supported transducer types.
  • Do not attempt to use external termination blocks with internal termination I/O modules.

Compliance and Certifications

Category Standard / Certification
EMC EN 61000-6-2, EN 61000-6-4 (Directive 2014/30/EU)
Electrical Safety EN 61010-1 (Directive 2014/35/EU)
RoHS Directive 2011/65/EU; China RoHS EFUP 15 years (SJ/T 11364-2024)
Hazardous Area (cNRTLus) Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (T4 @ Ta= -20 degC to +65 degC)
Hazardous Area (ATEX/IECEx) II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc (T4 @ Ta= -20 degC to +65 degC)
Maritime ABS-Marine and Offshore Applications; DNV GL Rules for Classification
Loading product navigation…

Where is the I/O module installed in the 3500 system rack?

The module installs in 1 full-height rear slot directly behind the matching monitor module.

Which transducer types can connect to this external termination module?

The device accepts Proximitor, accelerometer, Velomitor, and HTVS transducer inputs.

What cable is used to connect the module to the external termination block?

The module connects via the 129525 transducer signal to external termination block cable.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Color pattern
Perak
Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Memodernisasi HMI Bailey INFI 90 Symphony yang Berjalan di OpenVMS Alpha

Panduan praktis untuk mengganti stasiun operator Bailey Symphony yang sudah usang dan berjalan di OpenVMS Alpha. Panduan ini membandingkan emulasi Alpha, migrasi OpenVMS ke x86, pemindahan platform...

Mengapa Data Pemeliharaan Sangat Penting bagi Keandalan Industri

Data pemeliharaan menghubungkan perintah kerja, sinyal sensor, riwayat aset, biaya, dan pengetahuan teknisi. Jika digunakan dengan baik, data ini meningkatkan perencanaan, keandalan, pemeliharaan...

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kendali gerak industri dengan menggantikan sistem pneumatik dan hidraulik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan cara sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan eksponensiasi dalam otomasi industri. Artikel ini...