1 dari 1

Bently Nevada 3500/32-01-CN 3500 Series 4-Channel Relay Module

Bently Nevada 3500/32-01-CN 3500 Series 4-Channel Relay Module

Hanya 8 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 3500/32-01-CN

  • Negara asal:Amerika Serikat

  • Jenis Produk: Relay Modules

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

To drive external machinery control loops and execute critical protective safety shutdowns, the Bently Nevada 3500/32-01-CN integrates four fully programmable relay outputs into the 3500 series machinery protection rack. This full-height module accepts input logic from other monitors in the rack to control independent, single-pole double-throw (SPDT) relays. Highly configured for critical safety interlocking, the module provides reliable contact state changes based on alarm status and user-defined voting logic designed in the 3500 Rack Configuration Software.

Key Features

  • Four independent, programmable Single-Pole Double-Throw (SPDT) relay channels.
  • Compatible with standard 3500 series backplanes and slot structures.
  • Supports "Normally Energized" (NE) and "Normally De-energized" (NDE) configurations.
  • Extensive voting logic capability, allowing logical combinations of Alert and Danger statuses from multiple monitor channels.
  • Equipped with onboard health monitoring to ensure relay drive circuitry is functional.
  • CN designated option indicating compliance with specific country approval requirements.

Applications

  • Executive emergency machinery shutdown systems for steam turbines, gas turbines, and compressors.
  • Integration with Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC) for hardwired alarm annunciation.
  • Actuating local hazardous area alarm horns, beacons, and auxiliary indicators.
  • Interlocking critical process control loops based on physical machinery vibration boundaries.

Technical Specifications

Parameter Value / Specification
Manufacturer Bently Nevada
Model Number 3500/32-01-CN
Module Type 4-Channel Relay Output Module
Number of Channels 4 SPDT Relays
Relay Contact Rating (Resistive) 5 A @ 120 Vac / 240 Vac (Max); 5 A @ 30 Vdc (Max)
Minimum Contact Load 100 mA @ 5 Vdc
Agency Approvals Option CN (Country Specific Approvals)
Mounting Location Any full-height slot except Power Supply and Rack Interface Module slots
Country of Origin USA
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal Designation Functional Assignment
NO (Normally Open) Closes connection to Common when relay coil is energized.
NC (Normally Closed) Opens connection to Common when relay coil is energized.
COM (Common) Common reference pole for the respective channel's SPDT contact circuit.

Empirical Engineering Insights

Alternative Models & Compatibility

While the 3500 system also supports a 16-Channel Relay Module (the 3500/33), the 4-Channel 3500/32 provides robust SPDT Form-C outputs which are typically preferred for direct trip solenoid activation. Ensure that the 3500/32 firmware revision is compatible with your Rack Interface Module (RIM) firmware version before attempting slot allocation changes.

Application Pitfalls & Engineering Notes

When switching highly inductive AC loads (such as heavy solenoid valves or larger motor starters), installing external arc-suppression (RC snubbers) across the contacts is critical to prevent contact erosion and premature welding. Operating close to the 5 A limit without suppression can degrade relay lifespans and lead to dangerous "fail-to-open" states.

Commissioning & Wiring Tips

Always configure the "OK Relay" function correctly inside the configuration panel. Under normal running conditions, we recommend operating safety shutdown loops in a Normally Energized (NE) de-energize-to-trip mode. This ensures that a total loss of instrument control power automatically triggers the safe state of the machinery loop.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present on the relay contact terminals. Disconnect and lock out all external power sources supplying the relay contacts before servicing, removing, or replacing the module. Failure to de-energize external wiring can result in severe electrical shock, component destruction, or accidental machinery trip.
1

Power down the 3500 rack system if hot-swapping is not permitted by plant safety procedures. (The 3500 system supports hot-swapping under specific restricted environmental conditions).

2

Insert the main 3500/32-01-CN module into the front of the rack, sliding it along the guide rails until it is firmly seated in the backplane connector. Tighten the two securing screws on the front panel.

3

Mount the corresponding 4-channel relay I/O module into the back of the rack directly behind the front-facing slot. Secure it with its chassis panel screws.

4

Connect your alarm loop field wiring to the rear terminal block using proper wire-end ferrules to guarantee mechanical integrity and prevent short-circuiting between adjacent contact terminals.

Loading product navigation…

What is the configuration difference between the 4-channel and 16-channel relay modules in the 3500 system?

The 3500/32 is a 4-channel SPDT relay module, whereas the 3500/33 is a 16-channel relay module. The 4-channel version provides standard form-C SPDT contacts suitable for direct high-reliability protective action.

What does the 'CN' suffix designate for the 3500/32-01-CN module?

The 'CN' option designates country-specific approvals, specifically indicating compliance with Chinese national safety standards and regional certifications for deployment in localized industrial zones.

Are the relay outputs on the 3500/32-01-CN normally energized or normally de-energized?

Each relay can be independently programmed as normally energized (NE) or normally de-energized (NDE) using the 3500 Rack Configuration Software.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...