1 dari 1

Delta Electronics AH10DNET-5A AH Series DeviceNet Communication Module

Delta Electronics AH10DNET-5A AH Series DeviceNet Communication Module

Hanya 10 item tersisa di stok
  • Produsen: Delta Electronics

  • Nomor Produk: AH10DNET-5A

  • Negara asal:Amerika Serikat

  • Jenis Produk: DeviceNet Communication Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Processing of decentralized fieldbus data within Delta AH series automation architectures is managed directly by the Delta Electronics AH10DNET-5A DeviceNet master/slave communication module. This high-performance network interface integrates physical DeviceNet connectivity directly into the AH series PLC backplane, facilitating robust control over distributed I/O blocks, variable speed drives, and third-party industrial instruments. Equipped with hot-swapping support, the module minimizes production downtime during maintenance or expansion phases.

Features

  • Dual-Mode Flexibility: Easily switchable between master and slave configurations via software configurations.
  • Extensive Network Node Support: Connects up to 63 remote slave stations when operating in master mode.
  • High Data Throughput: Provides a robust Remote I/O (RIO) capacity of up to 490 words for both input and output registers.
  • In-Service Hot-Swapping: Allows module replacement without interrupting or de-energizing the main PLC rack operations.
  • Integrated Diagnostics: Dedicated module and network status LED indicators provide immediate visual fault isolation and network state verification.

Applications

  • Decentralized manufacturing lines requiring localized remote I/O scanning.
  • Multi-axis conveyor and sorting systems integrated with variable frequency drives.
  • Process control installations containing mixed-brand DeviceNet sensors and actuators.
  • Packaging machines demanding high-availability module hot-swapping capabilities.

Technical Specifications

Parameter Specification
Manufacturer Delta Electronics
Model Number AH10DNET-5A
Series AH Series
Module Type DeviceNet Communication Module
Internal Power Consumption 0.9 W
External Power Consumption 0.72 W
Communication Speed Supports up to 1 Mbps
Maximum Nodes (Master) 63 Slave Stations
RIO Capacity (Master Mode) 490 Words IN / OUT
Hot-Swapping Support Yes
Diagnostics On-board status LEDs (Module / Network Status)
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal / Pin Signal Allocation Standard Color Code
Pin 1 V- (Power Negative) Black
Pin 2 CAN_L (Signal Low) Blue
Pin 3 Shield (Drain / Ground) Bare / Silver
Pin 4 CAN_H (Signal High) White
Pin 5 V+ (Power Positive) Red

Empirical Engineering Insights

Alternative Models & Compatibility

The AH10DNET-5A is strictly compatible with Delta AH Series rack architectures (such as the AH500 CPU system). It cannot be integrated into DVP series or AS series backplanes. When integrating with legacy DeviceNet networks, verify that the EDS (Electronic Data Sheet) files match the specific firmware version marked on your hardware housing to prevent addressing mismatches during software mapping.

Application Pitfalls & Engineering Notes

A common issue encountered on site is voltage drop across extended trunk lines. While the module draws 0.9W internally from the backplane, the external transceiver circuit relies on 0.72W from the external 24 VDC bus. If the network voltage drops below 11 VDC at the farthest node, communication timeouts will occur. Always implement dedicated, isolated auxiliary power taps for long network runs.

Commissioning & Wiring Tips

Ensure that 121-ohm, 1/4W termination resistors are physically wired in parallel across CAN_H (Pin 4) and CAN_L (Pin 2) at both physical endpoints of the trunk line. Do not rely on internal software terminations, as reflections will degrade signal integrity. Verify that all node addresses (MAC IDs) are unique before enabling master mode execution.

Installation Guidelines

CRITICAL WARNING:

Ensure all main power supplies to the PLC backplane and external network transceivers are completely de-energized before handling or wiring the module. Although hot-swapping is supported by the hardware, live wiring connection of terminal blocks risks generating static arcs that can damage internal optocouplers.

1

Slide the module onto the AH series backplane slots until the release latches click securely into position.

2

Secure the 5-pin open connector by tightening the retaining screws, maintaining the standard color-code orientation (Black, Blue, Shield, White, Red).

3

Apply system power and verify that the front-panel LEDs cycle through self-test diagnostics before establishing master communication.

Loading product navigation…

Can the AH10DNET-5A act as both a master and a slave simultaneously?

No. The module is configurable to operate in either Master or Slave mode, but cannot run both profiles concurrently on the same network node.

What is the maximum remote I/O mapping capacity of this module?

When configured as a master, the module supports a maximum remote I/O capacity of 490 words for input and 490 words for output data.

Is the external 24 VDC power supply isolated from the internal PLC bus?

Yes, the internal 0.9W logic power is electrically isolated from the external 0.72W transceiver power supply, protecting the main PLC backplane from fieldbus electrical noise.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...