1 dari 1

Delta Electronics VFD1600C43A-00 C2000 Series Variable Frequency Drive

Delta Electronics VFD1600C43A-00 C2000 Series Variable Frequency Drive

Hanya 10 item tersisa di stok
  • Produsen: Delta Electronics

  • Nomor Produk: VFD1600C43A-00

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 86500g

  • Dimensi: 42 cm x 30 cm x 80 cm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for high-performance field-oriented control in heavy industrial automation systems, the Delta Electronics VFD1600C43A-00 is a premium three-phase AC motor drive belonging to the high-reliability C2000 Series. This variable frequency drive features dual-rating capabilities, allowing it to seamlessly adapt to both Normal Duty (ND) and Heavy Duty (HD) operational modes. Supporting an input voltage span of 323 to 528 VAC at 47 to 63 Hz, it achieves an optimal efficiency rating of 98.2%. Housed in a durable Frame Size F physical enclosure, this module integrates advanced velocity, torque, and position control algorithms, ensuring maximum motor shaft efficiency and reliable power management across heavy-duty industrial machinery.

Key Features

  • Dual-Rating Performance: Capable of driving up to 160 kW in Normal Duty (pump/fan) and 132 kW in Heavy Duty (constant torque) configurations.
  • High Operational Efficiency: Minimizes thermal loss and energy consumption with a verified 98.2% efficiency design.
  • Robust Voltage Handling: Designed for fluctuating power networks, accommodating input ranges from 323 to 528 Volts AC.
  • Advanced Vector Control: Supports closed-loop PM and IM motor control alongside standard V/f operations.
  • Integrated Fieldbus Capabilities: Features native communication options to integrate directly with factory-level industrial networks.

Applications

  • High-capacity industrial water pumps and municipal aeration systems.
  • Large-scale HVAC fans and industrial ventilation blowers.
  • Constant torque extruders, mixers, and industrial kneaders.
  • Material handling conveyor lines, overhead cranes, and hoist systems.
  • Industrial air compressors and gas booster stations.

Technical Specifications

Parameter Normal Duty (ND) Value Heavy Duty (HD) Value
Applicable Motor Output (kW) 160 kW 132 kW
Applicable Motor Output (HP) 215 HP 175 HP
Rated Output Current (A) 310 A 295 A
Rated Output Capacity (kVA) 247 kVA 235 kVA
Input Current (A) 300 A 285 A
General System Specifications
Operating Voltage Range 323 to 528 Volts AC (3-Phase)
Frequency Tolerance 47 to 63 Hz
Drive Efficiency 98.2%
Frame Size Frame F
Manufacturer Delta Electronics
Physical Dimensions (L x W x H) 42 cm x 30 cm x 80 cm
Net Unit Weight 86.5 kg
Shipping Weight 89.0 kg

Connections and Interfaces

Terminal Group Interface Type Functional Assignment
R/L1, S/L2, T/L3 Three-Phase AC Input Main power grid supply inputs.
U/T1, V/T2, W/T3 Three-Phase Motor Output Variable frequency output connections to the motor stator.
Digital Inputs Multi-Function Terminals (MI1 to MI8) Configurable sequence controls, emergency stop, and reset circuits.
Analog Inputs AVI (0-10V) / ACI (4-20mA) External frequency reference and feedback channel loop inputs.
Grounding PE Terminal Protective earth connection point to prevent chassis shock hazards.

Alternative Models & Compatibility

The VFD1600C43A-00 is highly backwards-compatible with standard parameters from older Delta VFD-F and VFD-B series drives, provided control loops are mapped to identical digital/analog logical terminals. When replacing older systems, ensure firmware parameters are re-verified, especially when utilizing closed-loop vector cards or optional network interfaces like MODBUS TCP or EtherNet/IP adapter modules.

Application Pitfalls & Engineering Notes

When operating Frame F units in enclosed cabinets, ensure continuous thermal management. Because the drive generates significant thermal output under continuous Heavy Duty loads (132 kW motor draw), a clean, filtered air cooling volume is strictly required. If installed in an unconditioned environment with high ambient temperatures exceeding 40 degC, derating the continuous current output capacity is mandatory to protect internal IGBT circuits from thermal shutdown.

Commissioning & Wiring Tips

For long motor cable runs exceeding 50 meters, output dV/dt filters or AC output reactors must be installed to prevent high voltage spikes from degrading motor winding insulation. To mitigate high-frequency electromagnetic interference (EMI) typical in large drives, control wires must be shielded and physically separated from high-voltage input and output line paths by at least 15 cm.

Installation Guidelines

CRITICAL WARNING:

Before performing any mechanical installation or wiring procedures, confirm all primary high-voltage line feeds are locked out and tagged out. After power-down, allow a minimum of 10 minutes for the internal high-voltage DC bus capacitors to completely discharge. Verify the DC bus voltage across terminals (+ and -) is under 36 VDC with a digital multimeter before contacting internal circuitry.

1

Ensure the installation surface is rigid, non-flammable, and vertically oriented to allow natural chimney-effect airflow through the cooling heat sinks.

2

Mount the heavy Frame F chassis securely using appropriate bolts, ensuring the structural backing can safely support the 86.5 kg physical load.

3

Connect the PE grounding terminal directly to the central electrical panel ground using thick, low-impedance conductor cables.

4

Terminate the main three-phase power input cables to terminals R/L1, S/L2, and T/L3. Never connect line utility power to the motor output terminals.

Loading product navigation…

What is the differences between Normal Duty and Heavy Duty ratings for this drive?

Under Normal Duty (ND), the drive supports motors up to 160 kW (215 HP) with a rated output current of 310 A. Under Heavy Duty (HD), which is required for high-torque start applications, it supports motors up to 132 kW (175 HP) with a rated current of 295 A.

Can this drive run closed-loop PM synchronous motors?

Yes. The Delta C2000 series supports synchronous permanent magnet (PM) motors in both open-loop and closed-loop configurations, provided the appropriate PG feedback card is installed.

What are the ventilation and space clearances required for Frame F drives?

Frame F requires significant cooling clearance due to its 86.5 kg size and heat generation. It is recommended to maintain at least 150 mm of vertical clearance above and below the drive and 50 mm on both sides inside the electrical cabinet.

What is the default communication protocol on this module?

The VFD1600C43A-00 comes with built-in RS-485 Modbus ASCII/RTU protocol. Optional communication cards can be integrated for PROFIBUS DP, DeviceNet, CANopen, and EtherNet/IP networks.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...