1 dari 1

Delta Electronics VFD370CP43B-21 CP2000 Series Fan/Pump Vector Control Drive

Delta Electronics VFD370CP43B-21 CP2000 Series Fan/Pump Vector Control Drive

Hanya 10 item tersisa di stok
  • Produsen: Delta Electronics

  • Nomor Produk: VFD370CP43B-21

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 11000g

  • Dimensi: 250 mm x 400 mm x 210 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Providing dedicated torque control for centrifugal pumps and ventilation systems, the Delta Electronics VFD370CP43B-21 drives 37 kW (50 HP) motors with high efficiency. This CP2000 Series variable frequency drive utilizes sensorless vector control to optimize power consumption based on real-time load demand. With a robust 460V three-phase input rating and a continuous output capacity of 73 Amps, this unit integrates seamlessly into municipal water systems, industrial cooling towers, and commercial HVAC networks.

Features

  • Optimized V/f and sensorless vector control (SVC) curves for variable torque loads.
  • Built-in 10k steps PLC capacity to execute local logic without external controllers.
  • Integrated PID control with sleep, wake, and redirection functions for pressure and flow systems.
  • Multi-pump synchronous control mode supporting fixed-quantity and circulating configurations.
  • Robust IP20 / NEMA 1 physical protection rating suited for wall-mounted control panels.
  • MODBUS communication protocol embedded for direct network integration.

Applications

  • Wastewater treatment facility pumping stations.
  • Commercial HVAC air handling units and supply fans.
  • Industrial cooling tower fan modulation.
  • Constant pressure clean water supply networks.

Technical Specifications

Parameter Specification
Manufacturer Delta Electronics
Model Number VFD370CP43B-21
Product Series CP2000
Applicable Motor Capacity 37 kW / 50 HP
Rated Output Current 73 Amps
Input Voltage / Phase 460V AC, 3-Phase
Installation Type Wall Mount
Enclosure Rating IP20 / NEMA 1
Physical Dimensions (W x H x D) 250 mm x 400 mm x 210 mm (9.84 in x 15.75 in x 8.27 in)
Net Weight 10.0 kg (22.0 lbs)
Shipping Weight (Calculated) 11.0 kg (24.2 lbs)

Empirical Engineering Insights

Alternative Models & Compatibility

The CP2000 series features standardized terminal footprints across similar frame sizes. When replacing legacy VFD-F series units, confirm that existing PLC program configurations are migrated using Delta's VFDSoft software to ensure register compatibility. Note that control terminal logic can be switched between SINK and SOURCE via an internal jumper on the main control board.

Application Pitfalls & Engineering Notes

In fan applications experiencing high wind-milling effects (where the fan rotates even when unpowered), always enable the "Spin Start" (catch on the fly) parameters. Attempting to start the drive into a rotating load without spin start enabled will trigger overcurrent (OC) or overvoltage (OV) trip faults immediately upon startup.

Commissioning & Wiring Tips

To minimize electromagnetic interference (EMI) affecting the 4-20mA pressure transducer feedback signal, ensure all analog control lines use twisted-pair shielded cables grounded exclusively at the drive-end shield terminal. For long motor cable runs exceeding 50 meters, the installation of an output AC reactor is highly recommended to protect motor windings from dv/dt degradation.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage levels remain present inside the unit after input power is disconnected. Wait a minimum of 10 minutes for the internal DC bus capacitors to discharge fully before removing the drive cover or touching any wiring terminals. Confirm zero voltage using a calibrated multimeter.
1
Mechanical Mounting: Bolt the VFD securely to a flat, vertical surface using the rear wall-mount brackets. Ensure a minimum clearance of 150 mm above and below the chassis to allow unimpeded airflow through the heatsink.
2
Power Terminations: Connect the 460V 3-phase input lines to terminals R/L1, S/L2, and T/L3. Connect the motor leads to U/T1, V/T2, and W/T3. Ensure the ground wire is connected securely to the primary PE terminal.
3
Motor Auto-Tuning: Perform an rotational or static auto-tune run with the motor decoupled from the load to optimize internal vector control algorithm parameters.
Loading product navigation…

What is the primary application for the VFD370CP43B-21?

This drive is specifically designed for variable torque loads such as centrifugal pumps, fans, and blower systems in HVAC and water treatment applications.

Does this drive contain an integrated PLC?

Yes, the CP2000 series has a built-in PLC with a program capacity of up to 10k steps for localized process control and logic automation.

What protection standard does the VFD370CP43B-21 enclosure meet?

The drive meets IP20 and NEMA 1 protection standards, making it suitable for clean, indoor dry panel environments.

What should be done if the motor cable run exceeds 50 meters?

An output AC reactor must be installed between the VFD output terminals and the motor to suppress dv/dt voltage spikes and protect winding insulation.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...