1 dari 1

Delta Electronics VFD450CP43S-21 CP2000 Fan/Pump Vector Control Drive

Delta Electronics VFD450CP43S-21 CP2000 Fan/Pump Vector Control Drive

Hanya 10 item tersisa di stok
  • Produsen: Delta Electronics

  • Nomor Produk: VFD450CP43S-21

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 40000g

  • Dimensi: 11.02 in x 24.19 in x 10.04 in

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Designed specifically for energy-efficient HVAC and pumping systems, the VFD450CP43S-21 is a high-performance variable frequency drive belonging to the premium Delta Electronics CP2000 series. This unit delivers precise sensorless vector control optimized for variable torque loads such as industrial fans, blowers, and centrifugal pumps. By dynamic adjustment of motor speed relative to real-time load demands, it significantly reduces energy consumption and mechanical wear across industrial processes.

The drive features an integrated PLC capability, allowing engineers to program custom logic sequences directly on the device without requiring external controllers. It supports multi-pump control algorithms out of the box, facilitating automated circulation, redundancy, and pressure control schemes. Housed in a durable wall-mount enclosure, the drive maintains steady performance under challenging operating conditions while offering straightforward integration into modern industrial networks.

Features

  • Advanced sensorless vector control (SVC) and V/F control modes tailored for variable torque applications.
  • Built-in PLC functionality with program capacity to execute localized control sequences and logic.
  • Multi-pump master/slave configurations supporting fixed-time and fixed-amount circulation.
  • Integrated PID feedback control with sleep and wake functions to optimize water and air delivery systems.
  • Modbus communication interface as standard for seamless connection to PLC and DCS architectures.
  • User-friendly LCD keypad providing real-time parameter configuration and fault-monitoring diagnostics.

Applications

  • HVAC air handling units (AHUs), ventilation fans, and cooling towers.
  • Municipal water supply systems and wastewater treatment pumping stations.
  • Industrial boiler feed pumps and recirculation loops.
  • Dust collection systems and centralized exhaust blowers.

Technical Specifications

ManufacturerPart Number / ModelSeriesApplicable Motor CapacityRated Output CurrentInput Voltage / PhaseInstallation TypeIP Protection LevelNEMA Protection LevelOperating TemperatureDimensions (W x H x D)Weight
Delta Electronics
VFD450CP43S-21
CP2000
60 HP (45 kW)
73 Amps
460V 3-Phase
Wall Mount
IP20
NEMA 1
-10 to 50 degC (without derating)
11.02 in x 24.19 in x 10.04 in
40 Kg

Installation Guidelines

For optimal reliability and safety, ensure the VFD450CP43S-21 is installed vertically on a non-combustible, flat vertical wall. Maintain a minimum clearance of 50 mm on both sides and 120 mm above and below the drive to ensure unobstructed airflow for the cooling fans. Since this module carries an IP20/NEMA 1 rating, it must be installed in a clean, dry, and dust-free environment protected from direct sunlight, corrosive gases, and moisture condensation.

Always connect the grounding terminal to a dedicated, low-impedance ground point (less than 10 ohms for 400V class systems) to minimize electromagnetic interference (EMI). Shielded motor cables are highly recommended to prevent cross-talk and RF noise emission into adjacent control instrumentation.

Loading product navigation…

What is the primary power rating of the Delta VFD450CP43S-21?

The VFD450CP43S-21 is rated for an applicable motor capacity of 60 HP (45 kW) with a rated continuous output current of 73 Amps.

What input voltage configuration does this variable frequency drive require?

This drive requires a 460V 3-phase input voltage supply.

What are the protection ratings of this physical unit?

The drive features an IP20 protection level and is rated for NEMA 1 indoor installations.

Can the VFD450CP43S-21 manage multiple pumps simultaneously?

Yes, the CP2000 series includes integrated multi-pump control algorithms for fixed-time and fixed-amount circulation directly via its built-in PID and PLC functions.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...