1 dari 1

Mitsubishi Electric FR-A840-00250-2-60 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-00250-2-60 FR-A800 Series Variable Frequency Drive

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-A840-00250-2-60

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 9000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Engineered for high-demand industrial speed and torque applications, the Mitsubishi Electric FR-A840-00250-2-60 is a premium FR-A800 Series variable frequency drive operating in the 400V voltage class. This standard-model inverter features specialized circuit board protective coating compliant with 3C2 specifications (without plated conductors) to ensure long-term reliability in corrosive, humid, or dusty environments. It supports advanced vector control methods to deliver precise motor dynamics for heavy-duty applications like cranes, extruders, and ventilation systems.

Key Features

  • Conformal PCB Coating: Engineered with standard 3C2-rated circuit board coating to withstand high moisture, chemical exposure, and particulate accumulation.
  • Advanced Vector Control: Supports real sensorless vector control and closed-loop vector control for absolute torque precision down to zero speed.
  • Dual Rating Capability: Optimizes sizing by allowing selection between Super Light Duty (SLD), Light Duty (LD), Normal Duty (ND), and Heavy Duty (HD) profiles.
  • Built-in PLC Functionality: Program internal logic using Mitsubishi Electric developer software to manage local I/O without an external controller.
  • Comprehensive Safety: Integrated safe torque off (STO) safety terminals comply with SIL 2 / PL d standards.

Applications

  • Material Handling: Dynamic hoist control, crane gantry synchronization, and heavy-duty conveyor systems requiring high starting torque.
  • Process Pumps & Compressors: Variable flow management under fluctuating load profiles in chemical processing and water treatment facilities.
  • Extruders and Mixers: High-inertia load management with precise speed holding under varying material viscosity.
  • Metalworking and Tensioning: Precise torque limitation and winding/unwinding control loops.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Code FR-A840-00250-2-60
Series FR-A800
Voltage Class 400 V Class (3-phase 380 to 500 V AC, 50Hz/60Hz)
SLD Rated Current 25.0 A
Control Method V/F Control, Advanced Magnetic Flux Vector, Real Sensorless Vector
PCB Coating Type Conformally Coated (Class 3C2), without plated conductor (-60)
Enclosure Rating IP20 (Open Type)
Operating Temperature -10 degC to 50 degC (non-freezing)
Device Net Weight 6.7 kg
Shipping Weight (Calculated) 9.0 kg

Control Terminals & Wiring Assignments

Terminal Symbol Terminal Name Functional Description
STF Forward Rotation Start Turn ON STF to start forward rotation; turn OFF to decelerate and stop.
STR Reverse Rotation Start Turn ON STR to start reverse rotation; turn OFF to decelerate and stop.
SD Contact Input Common Common terminal for contact input signals (sink logic standard).
10 Frequency Setting Power Supply DC 10V output for analog speed reference potentiometers.
2 Frequency Setting (Voltage) DC 0 to 5V or 0 to 10V analog speed command input.
4 Frequency Setting (Current) 4 to 20 mA DC analog speed command input.

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A840-00250-2-60 is directly backward compatible with older FR-A740-00250-EC installations. Users migrating to the FR-A800 series must utilize FR Configurator2 to convert parameter settings, ensuring torque boost and motor tuning values map correctly to the updated algorithm structure.

Application Pitfalls & Engineering Notes

When utilizing this inverter in closed cabinets, account for the 6.7 kg thermal footprint. Adequate airflow clearance must be maintained: 5 cm on both sides and 10 cm above/below the unit. Operating in temperatures exceeding 40 degC requires carrier frequency derating via Parameter 72 to prevent overtemperature tripping (E.THT or E.FIN).

Commissioning & Wiring Tips

Ensure that all analog control signals (terminals 2, 4, and 10) are wired with shielded, twisted-pair cables. Ground the shield exclusively at the drive-end SD terminal to prevent ground loops. Never route motor output leads (U, V, W) in the same conduit as control or communications cables.

Installation Guidelines

CRITICAL WARNING: Ensure main input line power (R/L1, S/L2, T/L3) is completely de-energized and locked out before attempting installation or maintenance. Wait a minimum of 10 minutes post-power-down for the DC bus capacitors to discharge. Verify the DC voltage across terminals P/+ and N/- is below 30V using a calibrated digital multimeter before handling terminals.
1

Mount the inverter vertically to a flat, rigid metal backplate to ensure optimal heat dissipation and grounding path efficiency.

2

Connect the protective earth (PE) terminal to the system ground busbar using low-impedance braided strap or green-and-yellow grounding conductor.

3

Wire the three-phase AC input to R/L1, S/L2, T/L3, and connect the motor leads to U, V, and W. Do not install a power factor correction capacitor on the output side.

4

Establish control wiring loop via standard sink logic or switch to source logic configuration utilizing the internal jumper block as specified by system drawings.

Loading product navigation…

What is the meaning of the -60 suffix on this inverter?

The -60 suffix denotes a standard model built with conformal circuit board coating compliant with IEC 60721-3-3 Class 3C2 for chemical/corrosive resistance, but without plated conductors.

Can I use the FR-A840-00250-2-60 with a single-phase supply?

No. This 400V class model is designed strictly for a balanced 3-phase AC input (380 to 500V, 50Hz or 60Hz).

How long must I wait to service the drive after disconnecting power?

You must wait at least 10 minutes to allow the DC bus capacitors to fully discharge. Always measure the DC voltage across terminals P/+ and N/- to confirm it is below 30V before handling.

Does this model support Modbus RTU communications out of the box?

Yes. This drive features built-in RS-485 communication ports on the control terminal block supporting Modbus RTU protocol as standard.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...