1 dari 1

Mitsubishi Electric FR-A840-01160-2-60 FR-A800 Variable Frequency Drive

Mitsubishi Electric FR-A840-01160-2-60 FR-A800 Variable Frequency Drive

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-A840-01160-2-60

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 41000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed to meet the rigorous demands of heavy industrial motor control, the Mitsubishi Electric FR-A840-01160-2-60 is a high-performance variable frequency drive (VFD) from the flagship FR-A800 series. This 400V class inverter delivers precise control with a Super Light Duty (SLD) rated current of 116A, making it ideal for high-capacity fan, pump, and machinery installations. Engineered with a specialized varnished circuit board coating (-60 specification), it provides reliable defense against humidity and dust in demanding environments. Its IP00 open-type physical structure is optimized for integration into centralized control panels, leveraging forced air cooling to maintain thermal efficiency under continuous operation.

Features

  • Varnished Circuit Boards: Enhanced conformal coating (-60 spec) safeguards control and power electronics from atmospheric contamination without plated conductors.
  • High Current Capacity: Operates at 116A under Super Light Duty (SLD) rating, supporting demanding heavy-duty continuous operations.
  • Robust Voltage Tolerances: Designed for standard three-phase 380V to 500V AC power systems, with a reliable fluctuation tolerance of 323V to 550V AC.
  • Panel-Optimized Design: Open-type IP00 rating allows efficient, space-saving panel installations with integrated forced-air cooling.
  • High-Precision Control: Part of the advanced FR-A800 family, supporting real sensorless vector control and vector control options.

Applications

  • Industrial Ventilation Systems: High-volume fan arrays, blowers, and clean-room exhaust systems requiring continuous speed modulation.
  • Water and Wastewater Management: Centrifugal pumps, booster stations, and fluid processing plants.
  • Heavy Machinery Control: Extruders, large conveyor lines, and material handling systems requiring steady-state torque control.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-A840-01160-2-60
Series FR-A800 Inverter Series
Voltage Class 400V Class
Rated Input AC Voltage Three-phase 380V to 500V AC, 50Hz/60Hz
Permissible AC Voltage Fluctuation 323V to 550V AC, 50Hz/60Hz
Permissible Frequency Fluctuation +/-5%
SLD Rated Current 116 A
Control/Structure Type Standard Model (-2 = CA Type)
Protective Structure Open Type (IP00)
Cooling Method Forced Air Cooling
Circuit Board Coating Varnished Conformal Coating (-60 specification)
Plated Conductor None
Product Weight 41 kg (90.4 lbs)
Shipping Weight (Calculated) 43 kg (94.8 lbs)

Connections and Interfaces

Terminal Block / Interface Functional Allocation
R/L1, S/L2, T/L3 Three-Phase AC Mains Power Input Terminals
U, V, W Three-Phase Variable Frequency AC Output to Motor
P/+, N/- DC Link Connection Terminals for Brake Unit or Shared DC Bus
PE Protective Earth / Chassis Ground Terminal
Control Terminals Dedicated I/O, Analog inputs (0-10V, 4-20mA), and multi-function relay outputs

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems from the FR-A700 series, the FR-A800 series provides backward parameters conversion. Parameter configurations can be imported using Mitsubishi’s FR Configurator2 software. Note that control terminal assignments are closely matched, but manual confirmation of safety-stop circuit allocations is required because of the safety standards implementation in the FR-A800 architecture.

Application Pitfalls & Engineering Notes

Because this VFD has a 41 kg weight footprint and relies on high-velocity forced air cooling, panel builders must ensure adequate airflow. Sealed enclosures require active heat exchangers or air conditioning units to handle the thermal load generated by the drive under continuous 116A SLD load conditions. Maintaining a minimum clearance of 100 mm above and below the cooling fans is necessary to prevent thermal shutdown events.

Commissioning & Wiring Tips

During initial power-up, verify that parameter 9 (electronic thermal O/L relay) matches your specific motor's nameplate data. Ensure all control-signal cables (such as 0-10V analog speed inputs) are routed in dedicated, shielded conduits distinct from high-power input/output cabling to eliminate high-frequency electromagnetic coupling.

Installation Guidelines

CRITICAL WARNING: Before commencing any installation or maintenance procedures, ensure all AC power sources feeding the R/L1, S/L2, and T/L3 terminals are physically locked out and tagged out. After power-off, wait a minimum of 10 minutes to allow the internal DC bus link capacitors to discharge completely. Verify that the voltage between terminals P/+ and N/- is 0V using a calibrated digital multimeter before handling terminals.
1

Mount the VFD vertically on a rigid, flat, heat-resistant surface inside the electrical enclosure to maximize convective air currents.

2

Connect the dedicated ground terminal (PE) directly to the system grounding plate using a low-impedance copper conductor.

3

Perform input power and motor terminal connections using calibrated torque tools, ensuring correct phase sequence on U, V, and W outputs.

Loading product navigation…

What is the physical meaning of the -60 suffix on the FR-A840-01160-2-60?

The -60 suffix specifies that the control and power printed circuit boards are treated with a specialized varnished conformal coating to improve environmental robustness, while omitting plated conductors.

What is the nominal and permissible voltage range for this inverter?

The drive accepts a nominal three-phase supply of 380V to 500V AC at 50/60Hz, with a maximum allowable voltage fluctuation range of 323V to 550V AC.

Can this unit be mounted horizontally to save enclosure space?

No. The FR-A840-01160-2-60 must be mounted vertically on a flat panel surface to preserve the effectiveness of its forced-air cooling system and prevent localized heat buildup.

How long must I wait after de-energization before performing wiring maintenance?

You must wait at least 10 minutes to allow the large internal DC-link capacitors to discharge. Always measure the voltage across terminals P/+ and N/- to confirm it is below safe thresholds before starting work.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...