1 dari 1

Mitsubishi Electric FR-F840-00250-2-60 FR-F800 Energy-Saving Inverter

Mitsubishi Electric FR-F840-00250-2-60 FR-F800 Energy-Saving Inverter

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-F840-00250-2-60

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 6500g

  • Dimensi: 170 mm x 220 mm x 260 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Optimizing motor control in HVAC, ventilation, and pumping applications, the FR-F840-00250-2-60 frequency inverter belongs to the renowned Mitsubishi Electric FR-F800 series of energy-saving variable speed drives. This high-efficiency unit is specifically engineered to control variable torque loads, utilizing advanced excitation control algorithms to minimize energy consumption in industrial systems.

The FR-F840-00250-2-60 operates on a three-phase supply voltage ranging from 380 to 500 V AC. It features dual rating capability, allowing operators to choose between Super Light Duty (SLD) and Light Duty (LD) profiles based on thermal and overload requirements. Designed for seamless integration into modern industrial control architectures, it offers reliable speed control, robust protective mechanisms, and high durability under demanding ambient conditions.

Features

  • Dual-rating operational profiles (Super Light Duty and Light Duty) for optimized motor sizing.
  • Advanced energy-saving algorithms that dynamically adjust motor excitation according to the current load.
  • High tolerance for line voltage fluctuations, accepting a wide input range from 323 to 550 V AC.
  • Integrated PID controllers for direct pressure, flow, and temperature process control loops.
  • Integrated cooling fan system with thermal management for high reliability.

Applications

  • Centrifugal pumps and booster pump systems in municipal and industrial water treatment.
  • Air handling units (AHUs), supply fans, and exhaust fans in commercial HVAC installations.
  • Cooling towers, chillers, and secondary pump circulation loops.
  • Industrial dust collection, exhaust systems, and blower applications.

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FR-F840-00250-2-60
Series FR-F800
Applicable Motor Capacity (SLD) 11 kW
Rated Input Voltage Three-phase 380 to 500 V AC
Input Frequency 50 Hz / 60 Hz
Permissible AC Voltage Fluctuation 323 to 550 V AC (50 Hz / 60 Hz)
Output Overload Rating (SLD) 110% for 60 seconds, 120% for 3 seconds (inverse-time characteristics) at surrounding air temperature of 40 degC
Output Overload Rating (LD) 120% for 60 seconds, 150% for 3 seconds (inverse-time characteristics) at surrounding air temperature of 50 degC
Dimensions (W x H x D) 170 mm x 220 mm x 260 mm
Weight 6.5 kg

Installation Guidelines

Ensure the inverter is mounted vertically on a flat, non-flammable surface to facilitate proper heat dissipation. Maintain a minimum clearance above, below, and to the sides of the drive as specified in the FR-F800 technical manual to prevent thermal choking. To minimize electromagnetic interference (EMI), utilize shielded cables for motor connections and ensure the drive chassis is securely grounded to the main system ground bus. Always isolate the input power supply before attempting any wiring modifications or terminal adjustments.

Loading product navigation…

What is the primary application for the Mitsubishi Electric FR-F840-00250-2-60 inverter?

This variable frequency drive is specifically engineered for energy-saving control of variable torque loads, such as fans, pumps, and blowers in industrial HVAC, building automation, and water treatment systems.

What are the overload capacities for this inverter?

The drive features a dual-rating system: Super Light Duty (SLD) allows for 110% overload for 60 seconds and 120% for 3 seconds at up to 40 degC. Light Duty (LD) allows for 120% overload for 60 seconds and 150% for 3 seconds at up to 50 degC.

What is the input voltage tolerance of this unit?

While rated for three-phase 380 V to 500 V AC at 50/60 Hz, the drive tolerates line voltage fluctuations from 323 V to 550 V AC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...