1 dari 1

Mitsubishi Electric FX5U-80MT/ESS MELSEC iQ-F Series PLC CPU Module

Mitsubishi Electric FX5U-80MT/ESS MELSEC iQ-F Series PLC CPU Module

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FX5U-80MT/ESS

  • Negara asal:Amerika Serikat

  • Jenis Produk: PLC CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 1200g

  • Dimensi: 305 mm x 110 mm x 100 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed as a high-performance control engine for the MELSEC iQ-F platform, the Mitsubishi Electric FX5U-80MT/ESS programmable logic controller offers exceptional processing speeds and integrated industrial functionalities. This module features 80 built-in I/O channels (comprising 40 source/sink 24V DC inputs and 40 source-type transistor outputs) designed to coordinate complex automation tasks. The controller incorporates native analog inputs and outputs, a dedicated RS-485 port, and an Ethernet interface to support diverse industrial communication requirements directly from the base unit without requiring additional expansion cards.

Key Features

  • High-Speed System Bus: Facilitates ultra-fast communication with extension modules, minimizing signal propagation delay.
  • Integrated Analog I/O: Built-in 2-channel analog input (0 to 10 V DC) and 1-channel analog output (0 to 10 V DC) for direct sensor and actuator interfacing.
  • Advanced Positioning: Supports built-in 4-axis positioning control with dedicated high-speed counter inputs.
  • Industrial Communications: Native RJ45 Ethernet port and screw-terminal RS-485 connection for seamless integration into factory networks.
  • SD Card Slot: Onboard memory card slot for program logging, firmware updates, and recipe management.

Applications

  • High-speed packaging and sorting machinery.
  • Multi-axis pick-and-place gantry systems.
  • Water treatment control panels with analog flow/pressure monitoring.
  • Conveyor control and material handling distribution systems.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Family MELSEC iQ-F Series (FX5U)
Supply Voltage 100 to 240 V AC (+10% / -15%), 50/60 Hz
Power Consumption 45 W
Total Built-in I/O Points 80 points (40 inputs, 40 outputs)
Input Specifications 24 V DC, 5.3 mA (X0 to X17) / 4.0 mA (X20 and later), Sink or Source configurable
Output Specifications Transistor (Source type), 5 to 30 V DC, 0.5 A per point
Built-in Analog Inputs 2 channels (0 to 10 V DC, input resistance 115 kOhms, 12-bit resolution)
Built-in Analog Output 1 channel (0 to 10 V DC, load resistance 2 kOhms to 1 MOhms, 12-bit resolution)
Built-in Communication Ports 1x RJ45 Ethernet (100Base-TX/10Base-T), 1x RS-485 (terminal block)
Operating Temperature 0 to 55 degC (32 to 131 degF)
Country of Origin Japan
Shipping Weight (Calculated) 1.2 kg (Net), 1.45 kg (Packaged)
Package Dimensions (Calculated) 305 mm x 110 mm x 100 mm

Connections and Interfaces

Terminal Block Section Signal / Pin Assignment Wiring Description
Power Terminals L, N, PE 100 to 240 V AC supply line, neutral, and physical protective earth.
Input Terminals S/S, X0 to X47 Configure S/S terminal for sink (connected to 24V) or source (connected to 0V) operations.
Output Terminals +V0 to +V4, Y0 to Y47 Source transistor outputs. External load connected between Y terminal and 0V line.
Analog Terminals V+, V-, CH1, CH2 Voltage inputs/outputs (0 to 10 V DC) for native processing. Shielded cables required.

Empirical Engineering Insights

Alternative Models & Compatibility

This controller serves as the direct evolutionary upgrade path for legacy FX3U systems. Migration from FX3U to FX5U requires software conversion via GX Works3. Be aware that the I/O terminal block alignment and physical footprint differ from older designs; ensure layout diagrams are updated to accommodate the compact housing of the FX5U model.

Application Pitfalls & Engineering Notes

When utilizing all 40 transistor outputs under continuous maximum switching states in a fully populated cabinet, local thermal limits can be reached. Ensure the enclosure provides adequate passive ventilation or active cooling to maintain ambient temperatures below 55 degC. To prevent inductive kickback from damage, external freewheeling diodes must be mounted parallel to inductive DC loads (solenoids, contactor coils) connected to Y0-Y47.

Commissioning & Wiring Tips

To configure the sink/source digital inputs, the S/S terminal must be explicitly jumpered. Wiring S/S to 24V establishes a sink input loop, whereas wiring S/S to 0V establishes a source loop. Do not leave the S/S terminal floating. For RS-485 communications, enable the terminal resistor (110 Ohm or 330 Ohm) via the built-in switch at physical bus boundaries to prevent data reflection and signal degradation.

Installation Guidelines

CRITICAL WARNING: Disconnect all primary power before mounting, terminating, or modifying wiring on the PLC. Failure to isolate power can result in permanent equipment damage, arc flash, or personal injury. Ensure the auxiliary 24 V DC power supply is monitored and protected by an external fast-acting fuse.
1

Mount the PLC onto a standard 35mm DIN rail inside a protective, IP54-rated or better cabinet to avoid contamination from conductive dust or moisture.

2

Ensure the physical ground terminal (PE) is connected directly to the main cabinet ground bus using a short, low-impedance conductor (minimum 2 mm² copper wire).

3

Isolate high-voltage AC lines from low-voltage DC and communication pathways in separate wire ducts to avoid EMI coupling.

Loading product navigation…

What is the primary difference between the ESS suffix and default FX5U models?

The ESS suffix designates that the module features source-type transistor outputs and uses European-style terminal blocks instead of standard sink-type layouts.

Can I use the integrated analog inputs for 4-20mA current loop signals?

No. The built-in analog inputs on the base unit are designed strictly for 0 to 10 V DC voltage inputs. For 4-20mA signals, an external analog expansion adapter must be added.

Does this CPU module require a separate battery to retain programs during power outages?

No. The unit uses non-volatile Flash ROM memory to store programs and parameters indefinitely without a battery. An optional battery is available only if extensive historical log retention is required.

What software is needed to program this device?

This module is configured and programmed using GX Works3 software within the IQ Works suite.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...