1 dari 1

Mitsubishi Electric FX5U-32MT/DS-TS MELSEC iQ-F Series CPU Module

Mitsubishi Electric FX5U-32MT/DS-TS MELSEC iQ-F Series CPU Module

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FX5U-32MT/DS-TS

  • Negara asal:Amerika Serikat

  • Jenis Produk: PLC CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 150 x 120 x 110 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Integrating advanced sequential and analog control into a compact form factor, the Mitsubishi Electric FX5U-32MT/DS-TS acts as the primary processing node for the MELSEC iQ-F controller platform. This CPU module features 32 integrated I/O channels (16 inputs, 16 outputs) equipped with Tension Spring (TS) terminal blocks, offering exceptional wiring speed and field reliability in high-vibration industrial settings. Operable on a 24V DC power supply, it integrates dual-port analog inputs, single-port analog output, high-speed counters, and multi-axis positioning interfaces without requiring additional expansion cards. Its execution speeds, coupled with built-in Ethernet and RS-485 ports, make it highly suited for modern, networked manufacturing architectures.

Features

  • Vibration-Proof Connections: Tension spring-clamp terminals eliminate screw-loosening risks and reduce field wiring installation times.
  • High-Speed Processing: Extremely fast basic instruction execution speeds of 34 nanoseconds optimize system response.
  • Built-In Communication: Integrates an Ethernet port for network integration and an RS-485 port for Modbus and dedicated inverter control.
  • Embedded Analog Capabilities: Features 2 channels of 12-bit analog input (0 to 10V DC) and 1 channel of analog output (0 to 10V DC).
  • Positioning Capabilities: Built-in high-speed counters up to 200 kHz and multi-axis positioning outputs for motion control applications.
  • Secure Data Management: Built-in SD memory card slot supports data logging, firmware updates, and simple project transfers.

Applications

  • High-vibration assembly and packaging systems
  • Conveyor tracking and automated material handling sorting
  • Automated dosing, pumping, and chemical treatment skids
  • Multi-axis pick-and-place assembly stations

Technical Specifications Table

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FX5U-32MT/DS-TS
Controller Series MELSEC iQ-F
Power Supply Voltage 24 V DC (+20%, -15%)
Integrated Inputs 16 Points (24 V DC, Sink/Source, 5.3 mA)
Integrated Outputs 16 Points (Transistor, Sink Type)
Terminal Type Tension Spring (Spring Clamp) Terminals
Analog Inputs 2 Channels (0 to 10 V DC, 12-bit conversion)
Analog Outputs 1 Channel (0 to 10 V DC, 12-bit conversion)
Memory Capacity 64k Steps Program Memory, 512k Words Data Memory
Built-in Comm Ports Ethernet (100Base-TX), RS-485 (Terminal)
Operating Temperature 0 to 55 degC
Shipping Weight (Calculated) 0.85 kg
Package Dimensions (Calculated) 150 x 120 x 110 mm

Connections and Interfaces

Terminal Group Assignment & Function
Power Supply 24V DC (+), 24V DC (-), Functional Ground (FG)
Digital Inputs (X0 - X17) 24V DC optocoupler-isolated inputs, sink/source configurable via common terminal
Digital Outputs (Y0 - Y17) Transistor outputs, sink type (common terminal connected to 0V)
Analog Inputs (V1+, V2+, V-) 2 channels of voltage inputs (0 to 10V DC) sharing a common return channel
Analog Output (Vout, Iout) 1 channel of analog output supporting voltage mode (0 to 10V DC)

Alternative Models & Compatibility

The FX5U-32MT/DS-TS can directly replace standard FX5U-32MT/DS models in terms of processing logic, firmware, and functional execution. However, the "-TS" suffix specifies tension spring terminals instead of the screw-terminal design on standard models. This physical difference requires matching wiring termination preparation (using solid core or correctly rated wire ferrules without crimping tools on insertion). Program files written in GX Works3 are completely cross-compatible between both physical termination versions.

Application Pitfalls & Engineering Notes

Since this CPU has a DC transistor sink-type output configuration, you must ensure that all inductive external loads (such as DC relays and solenoid valves) are properly installed with protective freewheeling diodes to prevent voltage kickback damage to the outputs. For thermal management inside closed control cabinets, a minimum space of 50 mm must be maintained above and below the module to ensure natural convection. Avoid running high-voltage AC cables alongside the low-voltage DC terminal lines inside the same ducting to prevent signal corruption.

Commissioning & Wiring Tips

When utilizing the built-in analog inputs and outputs, ensure that double-shielded twisted pair cables are used and that the shield is grounded only at a single, clean grounding point. The integrated spring-clamp terminals accept a wire cross-section of 0.2 to 1.5 mm² (AWG 24 to 16). Do not twist stranded wire ends before insertion unless they are terminated with a proper, uninsulated or insulated ferrule. A standard flathead screwdriver with a blade width of 2.0 to 2.5 mm is required to open the spring clamping mechanism for wire extraction.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources before mounting, dismantling, or servicing the unit. Failure to fully de-energize the incoming supply panel may result in serious electrical shock, hardware destruction, or erratic output switching states.

1

Snap the CPU module securely onto a standard 35 mm DIN rail or install it directly onto the backplate using the integrated mounting screw holes.

2

Verify that the 24V DC incoming feed is off, then terminate the power supply cables (+ and -) into the designated power terminals.

3

Using a suitable flat screwdriver, gently actuate the spring-clamp mechanisms to insert the control, I/O, and analog signal lines.

4

Verify ground terminal integrity by ensuring the Functional Ground (FG) is connected to the central cabinet earth grounding bar.

Loading product navigation…

What is the primary difference between the standard FX5U-32MT/DS and the -TS model?

The -TS model features Tension Spring (spring-clamp) connection terminal blocks instead of standard screw terminal blocks, which provides better resistance to vibration and faster manual wiring during commissioning.

What configuration software is required for programming this CPU?

The FX5U-32MT/DS-TS is fully programmed, configured, and diagnosed using Mitsubishi's GX Works3 programming software suite.

What output type is integrated on the FX5U-32MT/DS-TS?

It is equipped with 16 integrated transistor outputs configured for sink-type (NPN) switching operations.

Does this module include built-in analog capabilities?

Yes, it contains 2 channels of built-in 12-bit analog inputs (0 to 10 V DC) and 1 channel of built-in analog output (0 to 10 V DC).

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...