1 dari 1

Mitsubishi Electric GT1150-QBBD-C GOT1000 HMI Operator Interface

Mitsubishi Electric GT1150-QBBD-C GOT1000 HMI Operator Interface

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: GT1150-QBBD-C

  • Negara asal:Amerika Serikat

  • Jenis Produk: HMI Operator Panels

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 230 mm x 195 mm x 95 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Optimized for space-conscious machine-level monitoring, the Mitsubishi Electric GT1150-QBBD-C is a high-performance operator terminal belonging to the specialized GT11 sub-series of the GOT1000 platform. This hardware features a 5.7-inch STN blue-mode monochrome graphical display, engineered to deliver legible diagnostic feedback and interface layouts in challenging industrial environments. Equipped with an onboard 3 MB flash memory system, the unit handles complex screen layouts, alarm histories, and multi-language character sets. Physical communication interfaces include high-speed RS-232, RS-422/485 serial ports, and a dedicated USB connection, enabling robust connectivity directly to MELSEC series controllers or modern manufacturing networks.

Features

  • High-contrast 5.7-inch STN monochrome liquid crystal display with a resolution of 320 x 240 pixels.
  • Integrated 3 MB internal flash memory for efficient storage of project screens and system variables.
  • Multiple built-in ports featuring independent RS-232 and RS-422/485 channels to facilitate multi-device communication.
  • Front-accessible USB interface for direct system updates, programming, and OS restoration.
  • Integrated CompactFlash card slot supporting localized logging data and parameter backups.

Applications

  • Machine-level operational control in packaging and material handling lines.
  • Stand-alone assembly cells and custom manufacturing workstations.
  • Pumping stations, environmental monitoring, and localized HVAC control cabinets.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Reference GT1150-QBBD-C
Series Name GOT1000 (GT11 Platform)
Display Unit STN Monochrome (Blue/White) LCD
Screen Size 5.7 Inches
Display Resolution 320 x 240 Pixels
Supply Voltage 24 V DC (+10%, -15%)
User Memory Capacity 3 MB Built-in Flash
Backlight Type Cold cathode fluorescent tube (Replaceable)
External Interfaces RS-232, RS-422/485, USB (Mini-B)
Memory Extension Slot CompactFlash (CF) Card Slot (Max 2 GB)
Protection Rating IP67f (Front section when panel mounted correctly)
Operating Temperature 0 to 50 degC
Shipping Weight (Calculated) 1.45 kg
Package Dimensions (Calculated) 230 mm x 195 mm x 95 mm

Connections and Interfaces

Connector / Port Interface Specification Functional Use
RS-422/485 D-Sub 9-pin Female Primary PLC connection channel (MELSEC or major third-party protocols)
RS-232 D-Sub 9-pin Male Peripheral devices (scanners, printers) or serial PC upload/download
USB Device Mini-B Port High-speed screen design transfer, software communication, and OS updates
Power Terminal Screw Terminal Block 24 V DC power supply input with physical protective ground point

Alternative Models & Compatibility

The GT1150-QBBD-C variant features a conformal protective coating designed for harsh operating environments, distinguishing it from standard, non-coated GT1150-QBBD baseline models. When upgrading to this unit from legacy GOT900 series terminals (such as the F940GOT or GT10 series), screen databases can be seamlessly converted utilizing the migration wizard within GT Designer3. Ensure all communications drivers are updated to support the GT11 system architecture during project migration.

Application Pitfalls & Engineering Notes

As an STN monochrome blue LCD, the screen contrast of this unit is inherently susceptible to temperature shifts. In high-temperature electrical panels, the screen's baseline contrast may drop, leading to ghosting or low visibility. Users should utilize the built-in system utility screen to modify contrast registers or set up automatic contrast adjustments based on temperature. Ensure the surrounding panel cabinet retains a positive air draft if continuous exposure to temperatures close to 50 degC is expected.

Commissioning & Wiring Tips

To avoid communications dropouts or damage to the transceiver components, never route the RS-422/485 serial communication cables adjacent to 480 V high-current motor cables or variable frequency drive (VFD) output wires. Always attach a physical grounding strap to the grounding terminal of the terminal block to divert electromagnetic interference. When accessing the CF card slot, ensure the interface is unmounted or the device is powered off before ejecting the media card to avoid project data corruption.

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTROCUTION AND EQUIPMENT CRASH

Ensure all primary AC and subsidiary DC power sources feeding the target enclosure are fully locked out and tagged out prior to making physical cuts or performing wiring on the GT1150-QBBD-C. Use a calibrated multimeter to verify that the power lines are completely dead and that there are no residual energy pathways.

1

Verify the panel cutout meets the mandatory physical mounting dimensions for standard 5.7-inch GOT1000 panels.

2

Ensure the high-performance waterproof packing gasket is positioned flat, secure, and clear of debris inside the front bezel track of the device.

3

Insert the terminal into the panel cutout and tighten the four mounting screws systematically to the OEM-specified torque to avoid cracking the case.

4

Attach the dedicated 24 V DC supply leads to the screw terminals. Turn on power, enter the terminal configuration menu, and verify the physical system connection parameters match your controller.

Loading product navigation…

What is the primary input voltage requirement for the GT1150-QBBD-C?

This HMI terminal operates on a standard 24 V DC input power supply (+10%, -15% allowable range).

Which software is used to program or update this GOT1000 series terminal?

The screen designs and system settings are programmed using Mitsubishi Electric's GT Designer2 or GT Designer3 software.

What does the -C suffix at the end of the model number represent?

The -C suffix typically designates conformally coated internal PCB components, providing enhanced protection against humidity and airborne contaminants.

Can I save real-time data logs and system alarms to an external card?

Yes, the device contains an integrated CompactFlash (CF) card slot that supports external storage expansion up to 2 GB for logging data and parameters.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...