1 dari 1

Mitsubishi Electric L60TCTT4BW-CM MELSEC-L Series Temperature Control Module

Mitsubishi Electric L60TCTT4BW-CM MELSEC-L Series Temperature Control Module

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: L60TCTT4BW-CM

  • Negara asal:Amerika Serikat

  • Jenis Produk: PLC Temperature Control Modules

  • Pembayaran: T/T, Western Union

  • Berat: 330g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for precise, high-density thermal loop regulation, the Mitsubishi Electric L60TCTT4BW-CM provides advanced multi-channel temperature control directly integrated into the MELSEC-L Series PLC platform. This module features four independent thermocouple input channels combined with integrated heater burnout detection, allowing for real-time diagnostics and closed-loop PID control without relying on external transmitter hardware or heavy CPU overhead.

Features

  • Four thermocouple input channels supporting multiple sensor types for high flexibility.
  • Integrated heater disconnection detection using external current transformers (CT) to prevent process failures.
  • Internal PID control loop execution to offload thermal processing from the main PLC CPU.
  • Compact, rack-free modular structure designed for space-restricted control cabinets.
  • Direct parameterization and calibration via standard GX Works2 and GX Works3 software environments.

Applications

  • Plastic extrusion lines and injection molding thermal zones.
  • Industrial packaging machinery and heat-sealing bars.
  • Heat treatment furnaces, drying ovens, and industrial kilns.
  • Chamber temperature regulation in semiconductor manufacturing processes.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Code L60TCTT4BW-CM
Module Type Temperature Control Module (Thermocouple Type)
Number of Input Channels 4 Channels
Compatible Sensor Types Thermocouples: K, J, T, B, R, S, E, N, PLII, W5Re/W26Re
Heater Burnout Detection Supported (via external current transformer inputs)
Sampling Cycle 50 ms / channel
Internal Current Consumption (5V DC) 0.33 A
Weight 0.33 kg
Shipping Weight (Calculated) 2.00 kg
Country of Origin Japan

Connections and Interfaces

Terminal Group Functional Assignment
CH1 to CH4 (+ / -) Thermocouple sensor positive and negative differential inputs
CT1 to CT4 Current Transformer inputs for heater disconnection/burnout monitoring
CJC Cold Junction Compensation sensor connection point

Alternative Models & Compatibility

The L60TCTT4BW-CM serves as a direct drop-in replacement for standard L60TCTT4 series modules. The "-CM" suffix denotes localized documentation packaging but retains absolute hardware, electrical, and register-map parity. It mounts seamlessly to all MELSEC-L CPUs, including the L02CPU, L26CPU-BT, and standard fieldbus interface head modules.

Application Pitfalls & Engineering Notes

When deploying the heater disconnection feature, use only compatible current transformers (CTs) with precise turn ratios as specified in the MELSEC-L hardware manual. Unused thermocouple input channels must be explicitly disabled in the system parameter configurations to prevent the module from throwing sensor open-circuit faults and generating invalid diagnostic data.

Commissioning & Wiring Tips

To guarantee measurement integrity, always route thermocouple compensation cables through dedicated, low-voltage wire ways separate from 480V AC motor cables or VFD outputs. Ensure the shield of the compensation cable is grounded at a single, clean grounding terminal block near the PLC enclosure entry to prevent ground loops from corrupting the high-resolution analog-to-digital converters.

Installation Guidelines

CRITICAL WARNING: Disconnect all power sources feeding the PLC rack, sensor loops, and heater supply lines prior to starting the installation or physical wiring. Failure to isolate power can lead to critical component degradation, short circuits, or electrical shock.
1

Snap the module onto the standard 35mm DIN rail and engage the integrated side-locking joint to interface with the neighboring MELSEC-L module.

2

Connect the thermocouple sensor wires to the terminal block, paying strict attention to correct positive (+) and negative (-) polarity mapping.

3

Terminate the current transformer (CT) cables to the burnout detection pins if utilizing active heater health monitoring.

4

Power up the controller rack and transfer the hardware configuration, including sensor-scaling tables, using GX Works software.

Loading product navigation…

What sensor types are supported by the L60TCTT4BW-CM?

The module natively supports standard industrial thermocouples including K, J, T, B, R, S, E, N, PLII, and W5Re/W26Re configurations.

How does the heater burnout detection work?

It utilizes external current transformers (CTs) wired to dedicated CT inputs on the module, allowing real-time monitoring of current flow while control outputs are active.

Does the L60TCTT4BW-CM require a separate power supply?

No, it draws its primary operating power (0.33 A) directly from the 5V DC internal bus of the MELSEC-L system.

Can I use this module without connecting CT sensors?

Yes. If heater disconnection monitoring is not required, you can leave the CT inputs unwired and disable the detection alarm parameters in the configuration software.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...