This is a Siemens 6ES7132-4BD32-0AA0 digital output module for the SIMATIC ET 200S distributed I/O system. It provides a reliable interface for converting digital control signals into physical actions, operating field devices such as contactors, indicators, and solenoid valves. The module features four independent channels, each rated to switch 24 V DC loads at up to 2 A. Its compact 15mm width allows for high-density configurations in control cabinets, and it supports hot swapping to minimize system downtime during maintenance. This part number is typically supplied in a package of five individual modules.
| Part Number | Description | Package Quantity |
|---|---|---|
| 6ES7132-4BD32-0AA0 | SIMATIC ET 200S, Digital output module, 4 DO, 24V DC/2A | 5 Units |
| Specification | Value |
|---|---|
| Product Type | Digital Output Module |
| Product Series | SIMATIC ET 200S |
| Number of Digital Outputs | 4 |
| Output Voltage | 24 V DC |
| Output Current per Channel | 2 A |
| Module Width | 15 mm |
| Hot Swapping Capability | Supported |
| Lifecycle Status | Active |
| HS Code | 8537101190 |
| Shipping Weight | 0.95 kg |
| Package Dimensions (Calculated) | 2.5 x 5.1 x 8.4 cm |
| Manufacturer | Siemens |
| Country of Origin | Germany |
Disconnect all power sources to the ET 200S station and verify de-energization using a calibrated voltmeter before installing or removing modules. Failure to comply can result in severe injury or death. All work must be performed by qualified personnel familiar with industrial control systems and safety procedures.
Apply Lockout/Tagout (LOTO) procedures to the main power supply for the control cabinet and the 24 V DC power for the ET 200S station. Confirm zero voltage at the terminal module.
Align the electronic module with the corresponding ET 200S terminal module on the DIN rail. Ensure the coding elements on both modules match to prevent incorrect installation.
Carefully press the module onto the terminal module until it clicks securely into place. Verify that it is fully seated and flush with adjacent modules.
Once all modules are installed and field wiring is confirmed correct, remove LOTO devices and re-energize the system. Observe the module's diagnostic LEDs for correct startup status.