1 dari 1

Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232/485 Modbus TCP/RTU Gateway

Weidmuller 1504470000 IE-GWT-MB-2TX-1RS232/485 Modbus TCP/RTU Gateway

Hanya 10 item tersisa di stok
  • Produsen: Weidmuller

  • Nomor Produk: IE-GWT-MB-2TX-1RS232/485

  • Negara asal:Jerman

  • Jenis Produk: Modbus Gateways

  • Pembayaran: T/T, Western Union

  • Berat: 1000g

  • Dimensi: 29 mm x 124.5 mm x 89.2 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Facilitating seamless protocol translation between serial Modbus RTU/ASCII and Ethernet-based Modbus TCP networks, the Weidmuller 1504470000 (model IE-GWT-MB-2TX-1RS232/485) serves as an industrial-grade communication gateway designed for high-reliability automation environments. This device bridges legacy serial field devices with modern Ethernet control architectures, ensuring low-latency data transmission and robust network integration.

Key Features

  • Dual Ethernet ports (2TX) allowing for daisy-chain network topologies and simplified cabling.
  • Software-selectable serial interface supporting RS-232, RS-422, and RS-485 configurations.
  • Redundant 24 V DC power inputs to maximize system uptime and operational resilience.
  • Integrated Serial Redirection and Priority Control for optimized traffic management.
  • Compact, space-saving IP30 plastic housing designed for standard DIN rail mounting.

Applications

  • Substation automation and power monitoring network integration.
  • Connecting legacy serial PLCs and RTUs to modern SCADA host systems.
  • Water and wastewater treatment facility remote telemetry.
  • Factory automation and machine-to-machine (M2M) communication bridging.

Technical Specifications

Parameter Value
Manufacturer Weidmuller
Article Number (SKU) 1504470000
Model Designation IE-GWT-MB-2TX-1RS232/485
Ethernet Ports 2x RJ45 (10/100BaseT(X))
Serial Ports 1x RS-232/425/485 (DB9 male or terminal block options)
Supply Voltage 24 V DC (Redundant inputs)
Connector Type 1 removable 7-pole terminal block
Operating Temperature -40 to 75 degC
Storage Temperature -40 to 85 degC
Ambient Relative Humidity 5% to 95% (non-condensing)
Protection Class IP30
Housing Material Plastic
Mounting Type DIN rail
Dimensions (W x H x D) 29 mm x 124.5 mm x 89.2 mm
Net Weight 190 g
Shipping Weight (Calculated) 1.0 kg

Connections and Interfaces

Interface / Terminal Functional Assignment
7-Pole Terminal Block Redundant Power Input 1 (V1+, V1-), Redundant Power Input 2 (V2+, V2-), Functional Earth (FE)
RJ45 Ports (1 & 2) 10/100BaseT(X) Ethernet interfaces with auto MDI/MDI-X crossover detection
Serial Port RS-232 (TxD, RxD, GND) / RS-485 (Data+, Data-, GND) software-configurable pins

Empirical Engineering Insights

Alternative Models & Compatibility

The IE-GWT-MB-2TX-1RS232/485 is backward compatible with standard Modbus RTU devices operating over RS-485 2-wire networks. When replacing older single-port serial servers, the dual Ethernet ports on this model eliminate the need for an external switch in simple line topologies, reducing overall panel hardware costs.

Application Pitfalls & Engineering Notes

In high-density electrical cabinets, ensure adequate clearance around the IP30 plastic housing to maintain natural convection cooling. While rated up to 75 degC, operating continuously at extreme temperatures without proper ventilation can accelerate component aging. Always verify that the Modbus TCP client timeout settings are configured to accommodate the serial bus latency, especially when polling multiple daisy-chained RTU slaves.

Commissioning & Wiring Tips

When wiring the RS-485 network, always install a 120-ohm termination resistor at both physical ends of the communication line to prevent signal reflections. Ensure the Functional Earth (FE) terminal on the 7-pole block is connected directly to a low-impedance ground plane to safeguard the internal transceiver circuits from transient voltage spikes and electromagnetic interference.

Installation Guidelines

CRITICAL WARNING

Disconnect all power sources before attempting installation, wiring, or removal of the gateway. Failure to de-energize the system can result in electrical shock, equipment damage, or unexpected control system behavior.

1

Mount the gateway onto a standard TS 35 DIN rail, ensuring the locking mechanism snaps firmly into place.

2

Connect the Functional Earth (FE) terminal to the local ground system to ensure proper noise immunity.

3

Wire the redundant 24 V DC power supplies to the removable 7-pole terminal block, verifying correct polarity before energizing.

4

Connect the RJ45 Ethernet cables and the serial interface lines, securing all physical connections.

Loading product navigation…

What is the purpose of the dual Ethernet ports on the Weidmuller 1504470000?

The dual RJ45 ports (2TX) allow for daisy-chaining multiple Ethernet devices in a line topology, reducing the need for external network switches and simplifying field wiring.

Does this gateway support redundant power inputs?

Yes, the device features redundant 24 V DC power inputs via a removable 7-pole terminal block to ensure continuous operation if one power source fails.

How do I configure the serial port for RS-485 or RS-232?

The serial interface configuration (RS-232, RS-422, or RS-485) is software-selectable through the gateway's web-based management utility or configuration software.

What is the operating temperature range of the IE-GWT-MB-2TX-1RS232/485?

The gateway is designed for harsh environments, supporting an operating temperature range of -40 to 75 degC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...

Pemrograman Siklus Gerakan Sumbu Tunggal pada CMZ Servo Drive

Tutorial ini membahas bagaimana fungsi PLC onboard di dalam drive servo CMZ SBD dapat menjalankan program gerakan mandiri, termasuk logika homing, kontrol posisi, dan pergerakan sumbu siklik tanpa...