Danfoss

084G2107 Danfoss EMP 2 Series Heavy Duty Pressure Transmitter

SKU 084G2107

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 084G2107
  • Origin Denmark
  • Product Type: Pressure Transmitter
  • Payment: T/T, Western Union
  • Weight: 2.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The 084G2107 (084G2107) is a high-performance pressure transmitter from the renowned EMP 2 series, specifically engineered for demanding industrial and marine applications. Designed to monitor gauge (relative) pressure in systems ranging from 0 to 6 bar, this unit is a critical component for engine cooling systems, hydraulic power units, and water treatment automation. The 084G2107 is built to withstand harsh environmental conditions, offering a typical accuracy of 0.5% FS and long-term stability that minimizes maintenance cycles. Its robust terminal block connection and IP65-rated housing ensure reliable signal transmission even in high-vibration or high-moisture environments.

Technical Configuration

The 084G2107 features the EMP 2 series' signature heavy-duty design, utilizing a G 1/2 pressure connection (standard EN 228-1) with an internal G 1/4 interface for maximum mounting flexibility. Unlike flush-diaphragm models, this transmitter uses a standard pressure port optimized for clean or filtered liquids and gases. The electrical interface is managed via a Pg 13.5 terminal block, allowing for secure field wiring of the 4-20 mA output loop. To ensure precision across varying climates, the device includes an internal compensated temperature range of 0 to 70 deg C, which effectively filters out thermal-induced signal drift.

Technical Specifications

Attribute Specification
Model 084G2107
Brand Danfoss
Specification Key EMP 2-1811-F6CD24-2
Pressure Range 0 to 6 bar (0 to 87.02 psi)
Pressure Reference Gauge (Relative)
Output Signal 4 - 20 mA (Current)
Supply Voltage 12 - 32 VDC
Accuracy (Typical) 0.5 % FS
Pressure Connection G 1/2 Male / G 1/4 Female
Enclosure Rating IP65
Response Time 4 ms (Max)
Overload Pressure 18 bar
Net Weight 1.0 kg (Approx.)
Shipping Weight 2.5 kg

Technical FAQs

What are the wiring designations for the terminal block?

The 084G2107 uses a standard two-wire current loop configuration. Connect the positive DC supply to the P terminal (+ supply) and the return/common to the N terminal (- common).

How does the 18 bar overload pressure rating benefit my system?

The 18 bar rating provides a safety margin three times higher than the operating range (6 bar). This protects the internal sensing element from permanent damage or calibration shifts caused by sudden hydraulic surges or pressure spikes during system start-up.

Can this transmitter be used in seawater or corrosive chemical applications?

The EMP 2 series is generally built for durability; however, always verify that the wetted parts (G 1/2 stainless steel or alloy) are compatible with your specific medium. For highly corrosive acids, a chemical seal or isolated barrier may be required.


Engineering & Installation Guide

  • Terminal Block Wiring: Use the Pg 13.5 cable gland to ensure a watertight seal. When stripping wires for the terminal block, ensure no stray strands are protruding, as the compact spacing within the EMP 2 housing can lead to short circuits under high-vibration conditions.

  • Vibration Dampening: In marine engine or pump room installations, mount the transmitter on a bracket that is mechanically isolated from the primary vibration source. While the unit is rated for industrial use, constant high-frequency resonance can cause micro-fatigue in the internal electronics over several years of service.

  • Venting and Pressure Reference: Since this is a Gauge (Relative) pressure transmitter, ensure the internal reference port (located near the electrical entry) is not blocked by paint, grease, or heavy insulation. Proper venting is required for the sensor to accurately compare process pressure against current atmospheric pressure.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

084G2107

Stock & lead time on request

Call
1 su 1

084G2107 Danfoss EMP 2 Series Heavy Duty Pressure Transmitter

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 084G2107

  • Country of origin:Denmark

  • Product Type: Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The 084G2107 (084G2107) is a high-performance pressure transmitter from the renowned EMP 2 series, specifically engineered for demanding industrial and marine applications. Designed to monitor gauge (relative) pressure in systems ranging from 0 to 6 bar, this unit is a critical component for engine cooling systems, hydraulic power units, and water treatment automation. The 084G2107 is built to withstand harsh environmental conditions, offering a typical accuracy of 0.5% FS and long-term stability that minimizes maintenance cycles. Its robust terminal block connection and IP65-rated housing ensure reliable signal transmission even in high-vibration or high-moisture environments.

Technical Configuration

The 084G2107 features the EMP 2 series' signature heavy-duty design, utilizing a G 1/2 pressure connection (standard EN 228-1) with an internal G 1/4 interface for maximum mounting flexibility. Unlike flush-diaphragm models, this transmitter uses a standard pressure port optimized for clean or filtered liquids and gases. The electrical interface is managed via a Pg 13.5 terminal block, allowing for secure field wiring of the 4-20 mA output loop. To ensure precision across varying climates, the device includes an internal compensated temperature range of 0 to 70 deg C, which effectively filters out thermal-induced signal drift.

Technical Specifications

Attribute Specification
Model 084G2107
Brand Danfoss
Specification Key EMP 2-1811-F6CD24-2
Pressure Range 0 to 6 bar (0 to 87.02 psi)
Pressure Reference Gauge (Relative)
Output Signal 4 - 20 mA (Current)
Supply Voltage 12 - 32 VDC
Accuracy (Typical) 0.5 % FS
Pressure Connection G 1/2 Male / G 1/4 Female
Enclosure Rating IP65
Response Time 4 ms (Max)
Overload Pressure 18 bar
Net Weight 1.0 kg (Approx.)
Shipping Weight 2.5 kg

Technical FAQs

What are the wiring designations for the terminal block?

The 084G2107 uses a standard two-wire current loop configuration. Connect the positive DC supply to the P terminal (+ supply) and the return/common to the N terminal (- common).

How does the 18 bar overload pressure rating benefit my system?

The 18 bar rating provides a safety margin three times higher than the operating range (6 bar). This protects the internal sensing element from permanent damage or calibration shifts caused by sudden hydraulic surges or pressure spikes during system start-up.

Can this transmitter be used in seawater or corrosive chemical applications?

The EMP 2 series is generally built for durability; however, always verify that the wetted parts (G 1/2 stainless steel or alloy) are compatible with your specific medium. For highly corrosive acids, a chemical seal or isolated barrier may be required.


Engineering & Installation Guide

  • Terminal Block Wiring: Use the Pg 13.5 cable gland to ensure a watertight seal. When stripping wires for the terminal block, ensure no stray strands are protruding, as the compact spacing within the EMP 2 housing can lead to short circuits under high-vibration conditions.

  • Vibration Dampening: In marine engine or pump room installations, mount the transmitter on a bracket that is mechanically isolated from the primary vibration source. While the unit is rated for industrial use, constant high-frequency resonance can cause micro-fatigue in the internal electronics over several years of service.

  • Venting and Pressure Reference: Since this is a Gauge (Relative) pressure transmitter, ensure the internal reference port (located near the electrical entry) is not blocked by paint, grease, or heavy insulation. Proper venting is required for the sensor to accurately compare process pressure against current atmospheric pressure.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Denmark

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...