Bently Nevada

1900/65A-00-01-01-00-01 Bently Nevada 1900/65A General Purpose Equipment Monitor

SKU 1900/65A-00-01-01-00-01

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 1900/65A-00-01-01-00-01
  • Origin United States
  • Product Type: Equipment Monitor
  • Payment: T/T, Western Union
  • Weight: 4.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The 1900/65A-00-01-01-00-01 is a versatile and ruggedized general-purpose equipment monitor designed by Bently Nevada for non-critical machinery protection. This stand-alone system provides continuous monitoring and protection for a wide array of industrial assets including small pumps, motors, blowers, and fans in sectors such as power generation, wastewater treatment, and mining. Unlike high-end rack systems, the 1900/65A offers a cost-effective solution for providing essential vibration, temperature, and status information. By integrating four transducer inputs and four temperature inputs into a single compact unit, the 1900/65A-00-01-01-00-01 ensures that smaller assets receive the same level of engineering surveillance as major turbines, significantly reducing the risk of unexpected mechanical failure and optimizing maintenance schedules.

Technical Configuration

The 1900/65A-00-01-01-00-01 configuration is optimized for local control and seamless integration into plant-wide SCADA or PLC systems:

  • Power Option (00): Operates on 18 to 36 VDC, suitable for standard industrial power supplies and battery backup systems.
  • Display Option (01): Features an attached display unit, providing immediate local visibility of machine health without the need for additional cabling or remote consoles.
  • Mounting Option (01): Designed for standard DIN rail mounting, allowing for easy installation inside local control panels or specialized enclosures.
  • Approvals Option (00): Standard configuration for non-hazardous areas or general-purpose applications.
  • Communications Option (01): Equipped with Modbus RTU communication protocols, enabling direct digital data transfer to DCS, PLC, or HMI platforms for centralized monitoring.

Technical Specifications

Feature Details
Model 1900/65A-00-01-01-00-01
Brand Bently Nevada
Origin Made in U.S.A
Transducer Inputs 4 (Vibration/Dynamic)
Temperature Inputs 4 (Thermocouple/RTD)
Power Supply 18 to 36 VDC
Communication Modbus RTU via RS485
Mounting 35 mm DIN Rail
Operating Temperature -20 to +70 °C
Shipping Weight 4.0 kg

Technical FAQs

Can I configure this monitor for both vibration and temperature simultaneously?
Yes. The 1900/65A supports four channels of vibration (for example proximity probes or accelerometers) and four channels of temperature (RTDs or thermocouples) concurrently. This allows for a comprehensive assessment of the machine's mechanical and thermal condition.

What software is required to configure the 1900/65A-00-01-01-00-01?
The monitor is configured using Bently Nevada 1900 Configuration Software via a laptop connection. This software allows users to define alarm setpoints, select transducer types, and map Modbus registers.

Does this unit include internal relays for machinery shutdown?
Yes. The 1900/65A typically includes six programmable relays that can be configured for Alert and Danger levels. These relays provide hardware-level protective interlocking to shut down machinery during high-vibration or fault conditions.

Engineering & Installation Guide

  • Wiring for Noise Immunity: When connecting vibration transducers to the 1900/65A, use shielded twisted-pair cabling. Ensure that the shield is grounded only at the monitor end to prevent ground loops that could introduce false vibration signals.
  • DIN Rail Stability: Ensure the DIN rail is securely fastened to the enclosure backplate. Use end-stops to prevent the monitor from sliding or loosening on the rail.
  • Local Display Orientation: Position the display at operator eye level and protect it from direct sunlight. Long-term UV exposure can degrade the LCD panel and reduce readability.
  • Modbus Termination: For reliable RS485 communication over long cable distances, install a 120 Ohm termination resistor at both ends of the Modbus network. This minimizes signal reflections and prevents intermittent communication failures.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

1900/65A-00-01-01-00-01

Stock & lead time on request

Call
1 su 1

1900/65A-00-01-01-00-01 Bently Nevada 1900/65A General Purpose Equipment Monitor

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 1900/65A-00-01-01-00-01

  • Country of origin:United States

  • Product Type: Equipment Monitor

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The 1900/65A-00-01-01-00-01 is a versatile and ruggedized general-purpose equipment monitor designed by Bently Nevada for non-critical machinery protection. This stand-alone system provides continuous monitoring and protection for a wide array of industrial assets including small pumps, motors, blowers, and fans in sectors such as power generation, wastewater treatment, and mining. Unlike high-end rack systems, the 1900/65A offers a cost-effective solution for providing essential vibration, temperature, and status information. By integrating four transducer inputs and four temperature inputs into a single compact unit, the 1900/65A-00-01-01-00-01 ensures that smaller assets receive the same level of engineering surveillance as major turbines, significantly reducing the risk of unexpected mechanical failure and optimizing maintenance schedules.

Technical Configuration

The 1900/65A-00-01-01-00-01 configuration is optimized for local control and seamless integration into plant-wide SCADA or PLC systems:

  • Power Option (00): Operates on 18 to 36 VDC, suitable for standard industrial power supplies and battery backup systems.
  • Display Option (01): Features an attached display unit, providing immediate local visibility of machine health without the need for additional cabling or remote consoles.
  • Mounting Option (01): Designed for standard DIN rail mounting, allowing for easy installation inside local control panels or specialized enclosures.
  • Approvals Option (00): Standard configuration for non-hazardous areas or general-purpose applications.
  • Communications Option (01): Equipped with Modbus RTU communication protocols, enabling direct digital data transfer to DCS, PLC, or HMI platforms for centralized monitoring.

Technical Specifications

Feature Details
Model 1900/65A-00-01-01-00-01
Brand Bently Nevada
Origin Made in U.S.A
Transducer Inputs 4 (Vibration/Dynamic)
Temperature Inputs 4 (Thermocouple/RTD)
Power Supply 18 to 36 VDC
Communication Modbus RTU via RS485
Mounting 35 mm DIN Rail
Operating Temperature -20 to +70 °C
Shipping Weight 4.0 kg

Technical FAQs

Can I configure this monitor for both vibration and temperature simultaneously?
Yes. The 1900/65A supports four channels of vibration (for example proximity probes or accelerometers) and four channels of temperature (RTDs or thermocouples) concurrently. This allows for a comprehensive assessment of the machine's mechanical and thermal condition.

What software is required to configure the 1900/65A-00-01-01-00-01?
The monitor is configured using Bently Nevada 1900 Configuration Software via a laptop connection. This software allows users to define alarm setpoints, select transducer types, and map Modbus registers.

Does this unit include internal relays for machinery shutdown?
Yes. The 1900/65A typically includes six programmable relays that can be configured for Alert and Danger levels. These relays provide hardware-level protective interlocking to shut down machinery during high-vibration or fault conditions.

Engineering & Installation Guide

  • Wiring for Noise Immunity: When connecting vibration transducers to the 1900/65A, use shielded twisted-pair cabling. Ensure that the shield is grounded only at the monitor end to prevent ground loops that could introduce false vibration signals.
  • DIN Rail Stability: Ensure the DIN rail is securely fastened to the enclosure backplate. Use end-stops to prevent the monitor from sliding or loosening on the rail.
  • Local Display Orientation: Position the display at operator eye level and protect it from direct sunlight. Long-term UV exposure can degrade the LCD panel and reduce readability.
  • Modbus Termination: For reliable RS485 communication over long cable distances, install a 120 Ohm termination resistor at both ends of the Modbus network. This minimizes signal reflections and prevents intermittent communication failures.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.