Danfoss

AKV 20-4 (042H2027) Danfoss Electric Expansion Valve

SKU 042H2027

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss
  • Product No.: 042H2027
  • Origin United States
  • Product Type: Electric Expansion Valve
  • Payment: T/T, Western Union
  • Weight: 6.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The AKV 20-4 (042H2027) is a high-capacity, electronically operated expansion valve designed for precise liquid injection in industrial and commercial refrigeration plants. Utilizing the Pulse Width Modulation (PWM) principle, the Danfoss 042H2027 (042H2027) functions as both an expansion device and a liquid line solenoid valve, providing a tight shut-off when de-energized. This dual-purpose design is essential for B2B industrial applications such as large-scale cold storage, industrial chillers, and supermarket rack systems, where maintaining an exact superheat (SH) is critical for energy efficiency and compressor safety. The AKV 20-4 is engineered to provide higher mass flow rates than the AKV 20-1/2/3 models, making it suitable for high-output evaporator units.

Technical Configuration

The AKV 20-4 is built around a robust 13.5 mm actuator system and is typically driven by a Danfoss ADAP-KOOL controller. Rather than modulating the needle position, the valve cycles fully open and fully closed; the flow rate is determined by the duration of the "open" phase within the cycle. This mechanical simplicity results in a hermetic construction capable of withstanding millions of cycles without degradation. With a Maximum Working Pressure (PS) of 28 bar (406 psig), it is compatible with a wide range of HFC and HCFC refrigerants. The "Type 4" designation represents the specific high-capacity orifice size within the AKV 20 series framework.

Technical Specifications

Feature Specification
Model AKV 20-4 (042H2027)
Brand Danfoss
Product Type Electric Expansion Valve (PWM)
Actuator System 13.5 mm
Max Working Pressure (PS) 28 bar (406 psig)
Max Test Pressure 42 bar
Ambient Temp Range -40 to 50 Celsius
Function NC (Normally Closed)
Compatible Refrigerants R404A, R134a, R407C, R507, etc.
Weight 4.8 kg
Shipping Weight 6.0 kg

Technical FAQs

What are the specific advantages of PWM control for high-capacity systems?

In high-capacity systems, PWM control ensures that when the valve is open, the refrigerant velocity remains high. This assists in efficient oil return to the compressor and optimizes heat transfer within the evaporator by maintaining a consistent turbulence level, which is often superior to the partial-throttling found in mechanical valves.

Is an additional solenoid valve required for system safety?

No. The AKV 20-4 is a Normally Closed (NC) valve that provides a reliable, hermetic seal when the power is removed. This eliminates the hardware costs and pressure drops associated with installing an extra solenoid valve in the liquid line.

Can the internal orifice be replaced?

The AKV 20 series features a modular design where the orifice and needle assembly can be serviced or replaced if necessary, ensuring the valve body remains in place while restoring the valve to its original factory performance.


Engineering & Installation Guide

  • Upstream Filtration: Due to the rapid cycling nature of PWM valves, it is mandatory to install a high-quality filter drier (such as the Danfoss DML or DCL series) immediately before the valve. Debris in the liquid line can cause rapid wear on the valve seat or prevent the needle from sealing properly, leading to "flooding."

  • Brazing Thermal Protection: During installation of the solder connections, the valve body must be protected from excessive heat. Wrap the body in a wet cloth and ensure that the temperature of the 13.5 mm actuator housing does not exceed 100 Celsius. Overheating will damage the internal seals and the coil interface.

  • Electrical Configuration: Ensure the coil voltage matches the output of your Danfoss AK-CC or AKC controller. The coil must be mounted with the cable entry pointing downwards (creating a drip loop) to prevent moisture from traveling along the wire and into the actuator assembly.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

042H2027

Stock & lead time on request

Call
1 su 1

AKV 20-4 (042H2027) Danfoss Electric Expansion Valve

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 042H2027

  • Country of origin:United States

  • Product Type: Electric Expansion Valve

  • Payment: T/T, Western Union

  • Weight: 6000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The AKV 20-4 (042H2027) is a high-capacity, electronically operated expansion valve designed for precise liquid injection in industrial and commercial refrigeration plants. Utilizing the Pulse Width Modulation (PWM) principle, the Danfoss 042H2027 (042H2027) functions as both an expansion device and a liquid line solenoid valve, providing a tight shut-off when de-energized. This dual-purpose design is essential for B2B industrial applications such as large-scale cold storage, industrial chillers, and supermarket rack systems, where maintaining an exact superheat (SH) is critical for energy efficiency and compressor safety. The AKV 20-4 is engineered to provide higher mass flow rates than the AKV 20-1/2/3 models, making it suitable for high-output evaporator units.

Technical Configuration

The AKV 20-4 is built around a robust 13.5 mm actuator system and is typically driven by a Danfoss ADAP-KOOL controller. Rather than modulating the needle position, the valve cycles fully open and fully closed; the flow rate is determined by the duration of the "open" phase within the cycle. This mechanical simplicity results in a hermetic construction capable of withstanding millions of cycles without degradation. With a Maximum Working Pressure (PS) of 28 bar (406 psig), it is compatible with a wide range of HFC and HCFC refrigerants. The "Type 4" designation represents the specific high-capacity orifice size within the AKV 20 series framework.

Technical Specifications

Feature Specification
Model AKV 20-4 (042H2027)
Brand Danfoss
Product Type Electric Expansion Valve (PWM)
Actuator System 13.5 mm
Max Working Pressure (PS) 28 bar (406 psig)
Max Test Pressure 42 bar
Ambient Temp Range -40 to 50 Celsius
Function NC (Normally Closed)
Compatible Refrigerants R404A, R134a, R407C, R507, etc.
Weight 4.8 kg
Shipping Weight 6.0 kg

Technical FAQs

What are the specific advantages of PWM control for high-capacity systems?

In high-capacity systems, PWM control ensures that when the valve is open, the refrigerant velocity remains high. This assists in efficient oil return to the compressor and optimizes heat transfer within the evaporator by maintaining a consistent turbulence level, which is often superior to the partial-throttling found in mechanical valves.

Is an additional solenoid valve required for system safety?

No. The AKV 20-4 is a Normally Closed (NC) valve that provides a reliable, hermetic seal when the power is removed. This eliminates the hardware costs and pressure drops associated with installing an extra solenoid valve in the liquid line.

Can the internal orifice be replaced?

The AKV 20 series features a modular design where the orifice and needle assembly can be serviced or replaced if necessary, ensuring the valve body remains in place while restoring the valve to its original factory performance.


Engineering & Installation Guide

  • Upstream Filtration: Due to the rapid cycling nature of PWM valves, it is mandatory to install a high-quality filter drier (such as the Danfoss DML or DCL series) immediately before the valve. Debris in the liquid line can cause rapid wear on the valve seat or prevent the needle from sealing properly, leading to "flooding."

  • Brazing Thermal Protection: During installation of the solder connections, the valve body must be protected from excessive heat. Wrap the body in a wet cloth and ensure that the temperature of the 13.5 mm actuator housing does not exceed 100 Celsius. Overheating will damage the internal seals and the coil interface.

  • Electrical Configuration: Ensure the coil voltage matches the output of your Danfoss AK-CC or AKC controller. The coil must be mounted with the cable entry pointing downwards (creating a drip loop) to prevent moisture from traveling along the wire and into the actuator assembly.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Gold
Country of origin
United States
Power source
AC-powered

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.