The Basler Electric DECS-250-LN2SN1N is a digital excitation control system designed for precise voltage, var, and power factor regulation of synchronous generators and motors. The DECS-250-LN2SN1N configuration integrates a 24/48 Vac/Vdc power supply, internal and external autotracking capabilities, spring type terminals, and a 100Base-T Ethernet communication interface.
Equipped with a pulse-width-modulated (PWM) power stage delivering up to 15 Adc full-load continuous current, the system supports 1-phase or 3-phase true RMS sensing for voltage and current, integrated generator protection, auto-tuning stability controls, and diagnostic logging. Built-in communication interfaces include USB, RS-232, RS-485, CAN bus, and 100Base-T Ethernet for unit-to-unit communication and system setup via BESTCOMSPlus software.
| Style Code Element | Selection Code | Description |
|---|---|---|
| Power Supply | L | 24/48 Vac/Vdc |
| PSS | N | None |
| Autotracking | 2 | Internal/external autotracking |
| Terminals | S | Spring type |
| Synchronizer | N | None |
| 1st Communication Protocol | 1 | 100Base-T Ethernet |
| 2nd Communication Protocol | N | None |
| Parameter | Specification |
|---|---|
| Manufacturer | Basler Electric |
| Model | DECS-250-LN2SN1N |
| Product Type | Digital Excitation Control System |
| Power Supply Voltage (Style L) | 16 to 60 Vdc / 24/48 Vac/Vdc |
| Power Supply Burden | 50 VA or 30 W |
| Full Load Continuous Output Current | 15 Adc |
| 10-Second Forcing Output Current | 30 Adc |
| Power Input Frequency | 50 to 500 Hz |
| Generator & Bus Voltage Sensing Ranges | 100/120 Vac +/-10%, 200/240 Vac +/-10%, 400/480 Vac +/-10%, 600 Vac +/-10% |
| Generator Current Sensing Rating | 1 Aac or 5 Aac nominal, 50/60 Hz nominal |
| Contact Inputs | 16 programmable inputs (dry contacts) |
| Contact Outputs | 11 programmable form A contacts, 1 form C contact (watchdog function); rating 7 A resistive @ 24/48/125 Vdc / 120/240 Vac |
| Auxiliary Input | 4 to 20 mA or +/-10 Vdc input |
| Communication Ports | USB type B, RS-232 (9-pin sub D), RS-485 (Modbus RTU), CAN bus, Expansion Port, 100Base-T Ethernet (Modbus TCP) |
| Terminal Connection Type | Spring type |
| Operating Temperature | -40 degC to 70 degC (-40 degF to 158 degF) |
| Storage Temperature | -40 degC to 85 degC (-40 degF to 185 degF) |
| Shock Resistance | 15 G in three perpendicular planes |
| Vibration Resistance | 5 G from 18 to 2000 Hz in three perpendicular planes |
| Weight | 14.6 lb (6.62 kg) |
| Dimensions | 8.62 in x 12.00 in x 6.26 in (219.0 mm x 304.8 mm x 159.0 mm) (D x H x W) |
Global Express Shipping
Returns & Warranty




The Basler Electric DECS-250-LN2SN1N is a digital excitation control system designed for precise voltage, var, and power factor regulation of synchronous generators and motors. The DECS-250-LN2SN1N configuration integrates a 24/48 Vac/Vdc power supply, internal and external autotracking capabilities, spring type terminals, and a 100Base-T Ethernet communication interface.
Equipped with a pulse-width-modulated (PWM) power stage delivering up to 15 Adc full-load continuous current, the system supports 1-phase or 3-phase true RMS sensing for voltage and current, integrated generator protection, auto-tuning stability controls, and diagnostic logging. Built-in communication interfaces include USB, RS-232, RS-485, CAN bus, and 100Base-T Ethernet for unit-to-unit communication and system setup via BESTCOMSPlus software.
| Style Code Element | Selection Code | Description |
|---|---|---|
| Power Supply | L | 24/48 Vac/Vdc |
| PSS | N | None |
| Autotracking | 2 | Internal/external autotracking |
| Terminals | S | Spring type |
| Synchronizer | N | None |
| 1st Communication Protocol | 1 | 100Base-T Ethernet |
| 2nd Communication Protocol | N | None |
| Parameter | Specification |
|---|---|
| Manufacturer | Basler Electric |
| Model | DECS-250-LN2SN1N |
| Product Type | Digital Excitation Control System |
| Power Supply Voltage (Style L) | 16 to 60 Vdc / 24/48 Vac/Vdc |
| Power Supply Burden | 50 VA or 30 W |
| Full Load Continuous Output Current | 15 Adc |
| 10-Second Forcing Output Current | 30 Adc |
| Power Input Frequency | 50 to 500 Hz |
| Generator & Bus Voltage Sensing Ranges | 100/120 Vac +/-10%, 200/240 Vac +/-10%, 400/480 Vac +/-10%, 600 Vac +/-10% |
| Generator Current Sensing Rating | 1 Aac or 5 Aac nominal, 50/60 Hz nominal |
| Contact Inputs | 16 programmable inputs (dry contacts) |
| Contact Outputs | 11 programmable form A contacts, 1 form C contact (watchdog function); rating 7 A resistive @ 24/48/125 Vdc / 120/240 Vac |
| Auxiliary Input | 4 to 20 mA or +/-10 Vdc input |
| Communication Ports | USB type B, RS-232 (9-pin sub D), RS-485 (Modbus RTU), CAN bus, Expansion Port, 100Base-T Ethernet (Modbus TCP) |
| Terminal Connection Type | Spring type |
| Operating Temperature | -40 degC to 70 degC (-40 degF to 158 degF) |
| Storage Temperature | -40 degC to 85 degC (-40 degF to 185 degF) |
| Shock Resistance | 15 G in three perpendicular planes |
| Vibration Resistance | 5 G from 18 to 2000 Hz in three perpendicular planes |
| Weight | 14.6 lb (6.62 kg) |
| Dimensions | 8.62 in x 12.00 in x 6.26 in (219.0 mm x 304.8 mm x 159.0 mm) (D x H x W) |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|