BECKHOFF

Beckhoff CX5140-0122 CX5100 Series Embedded PC

SKU CX5140-0122

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: CX5140-0122
  • Origin Germany
  • Product Type: Embedded PCs
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Dimensions: 142 mm x 100 mm x 92 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Engineered for medium-to-high complexity automation tasks, the Beckhoff CX5140-0122 Embedded PC brings quad-core processing power directly to the DIN rail. This controller integrates an Intel Atom E3845 1.91 GHz processor, providing high-speed execution for TwinCAT-based control systems. With native support for both E-bus and K-bus I/O terminals, the unit automatically detects connected modules, facilitating seamless migration and expansion in diverse industrial environments.

Key Technical Features

  • Quad-Core Processing: Intel Atom E3845 CPU running at 1.91 GHz for deterministic control loops.
  • Dual I/O Interface: Automatic recognition and support for Beckhoff E-bus (EtherCAT) and K-bus (Bus Terminal) systems.
  • Integrated 1-Second UPS: Hardware-based persistent memory protection (1 MB on CFast card) to prevent data loss during sudden power failures.
  • Robust Connectivity: Dual independent RJ45 Gigabit Ethernet ports, four USB 2.0 ports, and a DVI-I diagnostic interface.
  • Passive Thermal Design: Fanless operation across a wide temperature range from -25 to +60 degC.

Industrial Applications

  • Machine Tool Control: High-speed PLC and motion control execution via TwinCAT 3.
  • Process Automation: Distributed control systems requiring robust communication interfaces and fieldbus integration.
  • Infrastructure & Energy: Remote monitoring and control in substations, water treatment plants, and wind turbines.
  • Hazardous Environments: Deployable in Zone 2/22 locations when configured with the optional CX2900-0107 thermal/protection package.

Technical Specifications

Specification Parameter Value / Configuration
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number CX5140-0122
Processor Intel Atom E3845, 1.91 GHz (4 Cores)
System Memory 4 GB DDR3 RAM (Non-expandable)
Storage Slots 1 x CFast card slot, 1 x microSD card slot (Cards not included)
Persistent Memory Integrated 1-second UPS (1 MB on CFast card)
Communication Interfaces 2 x RJ45 (10/100/1000 Mbit/s), 1 x DVI-I, 4 x USB 2.0
I/O Bus Connection E-bus (EtherCAT) or K-bus (Bus Terminal), automatic recognition
E-bus/K-bus Current Supply 2 A maximum
Power Supply Input 24 V DC (-15% / +20%)
Power Consumption 16 W (Standard), 23 W (During UPS charging)
TwinCAT Platform Level Performance Plus (Level 50)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight 1095 g
Shipping Weight (Calculated) 3 kg
Country of Origin Germany

Alternative Models & Compatibility

The CX5140-0122 is a quad-core alternative to the dual-core CX5130 series. It operates at TwinCAT 3 Platform Level 50 (Performance Plus), meaning any licenses transferred from lower-tier controllers (such as Level 40 Economy Plus units) must be upgraded to match this platform level. It maintains physical and electrical backplane compatibility with existing CX5010 and CX5020 installations, though software configurations must account for the updated Intel Atom E3845 architecture.

Application Pitfalls & Engineering Notes

Thermal Management: Although fanless, the CX5140-0122 relies on natural convection. It must be mounted vertically on a horizontal DIN rail. Maintaining a minimum clearance of 30 mm above and below the unit is mandatory to prevent thermal throttling when operating near the upper limit of 60 degC.
UPS Functionality: The integrated 1-second UPS requires a functional internal capacitive storage system. This UPS is designed solely to write persistent data (up to 1 MB) to the CFast card during a power loss event; it is not a system-level runtime UPS. Ensure the TwinCAT boot project is configured to trigger the write routine on power loss.

Commissioning & Wiring Tips

When wiring the 24 V DC power supply, ensure the supply line is fused externally. The E-bus/K-bus auto-detection occurs during the initial boot phase. If changing terminal types (e.g., swapping K-bus terminals for EtherCAT E-bus terminals), a full system cold restart is required for the controller to re-map the physical backplane interface. Ensure the total current draw of connected terminals does not exceed the 2 A backplane limit; if exceeded, a power supply terminal (e.g., CX2100-0xxx) must be integrated.

Installation Guidelines

CRITICAL WARNING Disconnect all electrical power sources before mounting, wiring, or removing the CX5140-0122. Verify that the 24 V DC supply is completely de-energized. Failure to isolate power can result in permanent damage to the internal processor, backplane ASIC, or connected I/O terminals. Ensure electrostatic discharge (ESD) protection protocols are followed when handling CFast or microSD storage media.
1

Mount the CX5140-0122 onto a standard 35 mm DIN rail (EN 60715) by hooking the top of the mounting clip over the rail and pressing down until it snaps securely into place.

2

Connect the functional ground (PE) wire directly to the grounding terminal of the power supply connector to ensure proper EMC shielding and noise immunity.

3

Insert a compatible, industrially rated CFast card containing the operating system and TwinCAT runtime into the designated slot before applying power.

4

Connect the 24 V DC power cables to the terminal block, verifying correct polarity, and power on the system to initiate the automatic I/O bus scan.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the TwinCAT 3 platform level for the CX5140-0122?
The CX5140-0122 is rated at TwinCAT 3 Platform Level 50 (Performance Plus). Ensure all runtime licenses match this level.
Can I use both E-bus and K-bus terminals simultaneously?
Yes, the CX5140-0122 features automatic bus recognition and can interface with either E-bus (EtherCAT) or K-bus (Bus Terminal) modules directly on the backplane.
How does the integrated 1-second UPS work?
The integrated UPS uses capacitive storage to provide power for approximately one second during a power outage. This is used exclusively to write up to 1 MB of persistent data to the CFast card.
Is the system memory expandable?
No, the 4 GB DDR3 RAM is integrated directly onto the motherboard and cannot be expanded or upgraded.
Reviews

CX5140-0122

Stock & lead time on request

Call
1 su 1

Beckhoff CX5140-0122 CX5100 Series Embedded PC

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX5140-0122

  • Country of origin:Germany

  • Product Type: Embedded PCs

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 142 mm x 100 mm x 92 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Engineered for medium-to-high complexity automation tasks, the Beckhoff CX5140-0122 Embedded PC brings quad-core processing power directly to the DIN rail. This controller integrates an Intel Atom E3845 1.91 GHz processor, providing high-speed execution for TwinCAT-based control systems. With native support for both E-bus and K-bus I/O terminals, the unit automatically detects connected modules, facilitating seamless migration and expansion in diverse industrial environments.

Key Technical Features

  • Quad-Core Processing: Intel Atom E3845 CPU running at 1.91 GHz for deterministic control loops.
  • Dual I/O Interface: Automatic recognition and support for Beckhoff E-bus (EtherCAT) and K-bus (Bus Terminal) systems.
  • Integrated 1-Second UPS: Hardware-based persistent memory protection (1 MB on CFast card) to prevent data loss during sudden power failures.
  • Robust Connectivity: Dual independent RJ45 Gigabit Ethernet ports, four USB 2.0 ports, and a DVI-I diagnostic interface.
  • Passive Thermal Design: Fanless operation across a wide temperature range from -25 to +60 degC.

Industrial Applications

  • Machine Tool Control: High-speed PLC and motion control execution via TwinCAT 3.
  • Process Automation: Distributed control systems requiring robust communication interfaces and fieldbus integration.
  • Infrastructure & Energy: Remote monitoring and control in substations, water treatment plants, and wind turbines.
  • Hazardous Environments: Deployable in Zone 2/22 locations when configured with the optional CX2900-0107 thermal/protection package.

Technical Specifications

Specification Parameter Value / Configuration
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number CX5140-0122
Processor Intel Atom E3845, 1.91 GHz (4 Cores)
System Memory 4 GB DDR3 RAM (Non-expandable)
Storage Slots 1 x CFast card slot, 1 x microSD card slot (Cards not included)
Persistent Memory Integrated 1-second UPS (1 MB on CFast card)
Communication Interfaces 2 x RJ45 (10/100/1000 Mbit/s), 1 x DVI-I, 4 x USB 2.0
I/O Bus Connection E-bus (EtherCAT) or K-bus (Bus Terminal), automatic recognition
E-bus/K-bus Current Supply 2 A maximum
Power Supply Input 24 V DC (-15% / +20%)
Power Consumption 16 W (Standard), 23 W (During UPS charging)
TwinCAT Platform Level Performance Plus (Level 50)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight 1095 g
Shipping Weight (Calculated) 3 kg
Country of Origin Germany

Alternative Models & Compatibility

The CX5140-0122 is a quad-core alternative to the dual-core CX5130 series. It operates at TwinCAT 3 Platform Level 50 (Performance Plus), meaning any licenses transferred from lower-tier controllers (such as Level 40 Economy Plus units) must be upgraded to match this platform level. It maintains physical and electrical backplane compatibility with existing CX5010 and CX5020 installations, though software configurations must account for the updated Intel Atom E3845 architecture.

Application Pitfalls & Engineering Notes

Thermal Management: Although fanless, the CX5140-0122 relies on natural convection. It must be mounted vertically on a horizontal DIN rail. Maintaining a minimum clearance of 30 mm above and below the unit is mandatory to prevent thermal throttling when operating near the upper limit of 60 degC.
UPS Functionality: The integrated 1-second UPS requires a functional internal capacitive storage system. This UPS is designed solely to write persistent data (up to 1 MB) to the CFast card during a power loss event; it is not a system-level runtime UPS. Ensure the TwinCAT boot project is configured to trigger the write routine on power loss.

Commissioning & Wiring Tips

When wiring the 24 V DC power supply, ensure the supply line is fused externally. The E-bus/K-bus auto-detection occurs during the initial boot phase. If changing terminal types (e.g., swapping K-bus terminals for EtherCAT E-bus terminals), a full system cold restart is required for the controller to re-map the physical backplane interface. Ensure the total current draw of connected terminals does not exceed the 2 A backplane limit; if exceeded, a power supply terminal (e.g., CX2100-0xxx) must be integrated.

Installation Guidelines

CRITICAL WARNING Disconnect all electrical power sources before mounting, wiring, or removing the CX5140-0122. Verify that the 24 V DC supply is completely de-energized. Failure to isolate power can result in permanent damage to the internal processor, backplane ASIC, or connected I/O terminals. Ensure electrostatic discharge (ESD) protection protocols are followed when handling CFast or microSD storage media.
1

Mount the CX5140-0122 onto a standard 35 mm DIN rail (EN 60715) by hooking the top of the mounting clip over the rail and pressing down until it snaps securely into place.

2

Connect the functional ground (PE) wire directly to the grounding terminal of the power supply connector to ensure proper EMC shielding and noise immunity.

3

Insert a compatible, industrially rated CFast card containing the operating system and TwinCAT runtime into the designated slot before applying power.

4

Connect the 24 V DC power cables to the terminal block, verifying correct polarity, and power on the system to initiate the automatic I/O bus scan.

What is the TwinCAT 3 platform level for the CX5140-0122?

The CX5140-0122 is rated at TwinCAT 3 Platform Level 50 (Performance Plus). Ensure all runtime licenses match this level.

Can I use both E-bus and K-bus terminals simultaneously?

Yes, the CX5140-0122 features automatic bus recognition and can interface with either E-bus (EtherCAT) or K-bus (Bus Terminal) modules directly on the backplane.

How does the integrated 1-second UPS work?

The integrated UPS uses capacitive storage to provide power for approximately one second during a power outage. This is used exclusively to write up to 1 MB of persistent data to the CFast card.

Is the system memory expandable?

No, the 4 GB DDR3 RAM is integrated directly onto the motherboard and cannot be expanded or upgraded.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...