BECKHOFF

BECKHOFF IP1010-B200 Lightbus Fieldbus Box

SKU IP1010-B200

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP1010-B200
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 0.25 kg
  • Dimensions: 30 mm x 210 mm x 26.5 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The BECKHOFF IP1010-B200 is an 8-channel digital input Fieldbus Box designed for decentralized automation tasks in rugged industrial environments. It serves as a reliable link between binary sensors and the Lightbus fiber-optic fieldbus system, allowing digital signals to be captured directly at the machine level without requiring a protective control cabinet.

Constructed with a highly durable PA6 polyamide enclosure, this module offers robust IP65/66/67 protection against moisture, dust, and mechanical stress. It features 8 mm snap-type connection technology for fast, tool-free sensor integration and incorporates an integrated 0.2 ms input filter to ensure stable signal processing in high-speed applications.

The fieldbus connection is established via high-speed Lightbus fiber-optic interfaces, operating at up to 2.5 Mbaud. This fiber-optic medium provides excellent noise immunity and complete electrical isolation, making the module ideal for environments with severe electromagnetic interference (EMI).

Features

  • 8 digital input channels with a nominal operating voltage of 24 V DC.
  • Fast-response input filter of 0.2 ms for rapid signal transitions.
  • Lightbus fiber-optic interface supporting data transfer rates of 2.5 Mbaud.
  • Rugged polyamide PA6 housing featuring IP65, IP66, and IP67 ratings.
  • 8 mm snap-type sockets for quick and vibration-resistant sensor connections.
  • Short-circuit proof sensor supply (up to 0.5 A total) derived from the control voltage.
  • M8 4-pin power connection layout with upstream feed-through capabilities.

Applications

  • Decentralized machine mounting and tool-head control systems.
  • Material handling, conveying, and sorting systems where field cabinets are impractical.
  • High-EMI manufacturing zones requiring optical fiber signal isolation.
  • Automated assembly lines and packaging machinery.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1010-B200
Product Type Fieldbus Box (Digital Input)
Enclosure Material PA6 (Polyamide)
Protection Class IP65, IP66, IP67 (conforms to EN 60529)

Signal and I/O

Parameter Specification
Number of Inputs 8
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V (EN 61131-2, Type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, Type 2)
Input Current Typically 6 mA (EN 61131-2, Type 2)
Input Filter Delay 0.2 ms
Sensor Supply From control voltage, max. 0.5 A total, short-circuit proof
Input Sockets 8 mm snap-type

Lightbus and Communication

Parameter Specification
Data Transfer Rate 2.5 Mbaud
Data Transfer Medium APF (plastic) fiber-optic conductor (1,000 um)
Max. Station Distance 45 m
Bus Interface 2 x fiber-optic socket for plug ZS1020-0010
Process Image Bit Width 8 inputs

Power Supply

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Interface Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Electrical Isolation Control voltage to fieldbus: Yes

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 250 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Mounting Method 2 x 3.5 mm diameter fixing holes for M3 screws
Approvals/Markings CE, UL

Connections / Interfaces

Interface / Terminal Function
8 mm Snap Sockets (1 to 8) Digital Input Channels 1 through 8
M8 Male Connector (4-pin) Incoming 24 V DC Control Voltage Feed
M8 Female Connector (4-pin) Downstream 24 V DC Power Supply Loop-through
Fiber-Optic Sockets Lightbus Incoming and Outgoing optical rings

Installation Guidelines

  1. Ensure all power supplies are de-energized before mounting, wiring, or servicing the unit.
  2. Secure the Fieldbus Box using the two 3.5 mm mounting holes with M3 fasteners. Ensure the mounting surface is flat to avoid mechanical stress on the housing.
  3. Verify the maximum permissible bending radius for the fiber-optic cables during routing to prevent attenuation and transmission failures.
  4. Connect the incoming 24 V DC control voltage to the M8 male connector. If daisy-chaining, connect downstream modules to the M8 female connector.
  5. Install the 8 mm snap-type sensor connections, verifying that the sensors operate within the matching 24 V DC signal parameters.
  6. Power up the control supply and verify system communication status via the controller interface.

Replacement Recommendations

  1. Shut down and lock out the primary 24 V DC control voltage feeding the station.
  2. Disconnect the fiber-optic cables carefully, protecting the optical terminals from dust, debris, and oil contaminants.
  3. Unplug all 8 mm snap-type input sensors and label each corresponding channel position to prevent rewiring errors.
  4. Remove the M8 power cables and unscrew the mounting fasteners to detach the old module.
  5. Mount the replacement module, secure all connections as previously mapped, and run initial physical checks before re-energizing.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP1010-B200?
The BECKHOFF IP1010-B200 is an 8-channel digital input Fieldbus Box designed to capture 24 V DC binary signals directly in the field and transmit them to a controller using the fiber-optic Lightbus network interface.
What connector types are used on the BECKHOFF IP1010-B200?
The BECKHOFF IP1010-B200 features 8 mm snap-type sockets for digital inputs, M8 4-pin sockets for control voltage distribution (one male feed and one female loop-through), and two specialized fiber-optic sockets for Lightbus communication.
Does the BECKHOFF IP1010-B200 require a protective enclosure?
No, the BECKHOFF IP1010-B200 does not require a control cabinet as its durable PA6 polyamide housing provides IP65, IP66, and IP67 protection ratings, permitting direct machinery installation in harsh conditions.
What are the fiber-optic connection requirements for the BECKHOFF IP1010-B200?
The BECKHOFF IP1010-B200 communicates via an APF plastic fiber-optic medium (1,000 um) with a maximum distance of 45 meters between stations and connects using plug model ZS1020-0010.
Is the sensor supply on the BECKHOFF IP1010-B200 protected?
Yes, the BECKHOFF IP1010-B200 provides a sensor supply sourced from the control voltage that is fully short-circuit proof with a maximum total current limit of 0.5 A.
Reviews

IP1010-B200

Stock & lead time on request

Call
1 su 1

BECKHOFF IP1010-B200 Lightbus Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP1010-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 30 mm x 210 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF IP1010-B200 is an 8-channel digital input Fieldbus Box designed for decentralized automation tasks in rugged industrial environments. It serves as a reliable link between binary sensors and the Lightbus fiber-optic fieldbus system, allowing digital signals to be captured directly at the machine level without requiring a protective control cabinet.

Constructed with a highly durable PA6 polyamide enclosure, this module offers robust IP65/66/67 protection against moisture, dust, and mechanical stress. It features 8 mm snap-type connection technology for fast, tool-free sensor integration and incorporates an integrated 0.2 ms input filter to ensure stable signal processing in high-speed applications.

The fieldbus connection is established via high-speed Lightbus fiber-optic interfaces, operating at up to 2.5 Mbaud. This fiber-optic medium provides excellent noise immunity and complete electrical isolation, making the module ideal for environments with severe electromagnetic interference (EMI).

Features

  • 8 digital input channels with a nominal operating voltage of 24 V DC.
  • Fast-response input filter of 0.2 ms for rapid signal transitions.
  • Lightbus fiber-optic interface supporting data transfer rates of 2.5 Mbaud.
  • Rugged polyamide PA6 housing featuring IP65, IP66, and IP67 ratings.
  • 8 mm snap-type sockets for quick and vibration-resistant sensor connections.
  • Short-circuit proof sensor supply (up to 0.5 A total) derived from the control voltage.
  • M8 4-pin power connection layout with upstream feed-through capabilities.

Applications

  • Decentralized machine mounting and tool-head control systems.
  • Material handling, conveying, and sorting systems where field cabinets are impractical.
  • High-EMI manufacturing zones requiring optical fiber signal isolation.
  • Automated assembly lines and packaging machinery.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1010-B200
Product Type Fieldbus Box (Digital Input)
Enclosure Material PA6 (Polyamide)
Protection Class IP65, IP66, IP67 (conforms to EN 60529)

Signal and I/O

Parameter Specification
Number of Inputs 8
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V (EN 61131-2, Type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, Type 2)
Input Current Typically 6 mA (EN 61131-2, Type 2)
Input Filter Delay 0.2 ms
Sensor Supply From control voltage, max. 0.5 A total, short-circuit proof
Input Sockets 8 mm snap-type

Lightbus and Communication

Parameter Specification
Data Transfer Rate 2.5 Mbaud
Data Transfer Medium APF (plastic) fiber-optic conductor (1,000 um)
Max. Station Distance 45 m
Bus Interface 2 x fiber-optic socket for plug ZS1020-0010
Process Image Bit Width 8 inputs

Power Supply

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Interface Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Electrical Isolation Control voltage to fieldbus: Yes

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 250 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Mounting Method 2 x 3.5 mm diameter fixing holes for M3 screws
Approvals/Markings CE, UL

Connections / Interfaces

Interface / Terminal Function
8 mm Snap Sockets (1 to 8) Digital Input Channels 1 through 8
M8 Male Connector (4-pin) Incoming 24 V DC Control Voltage Feed
M8 Female Connector (4-pin) Downstream 24 V DC Power Supply Loop-through
Fiber-Optic Sockets Lightbus Incoming and Outgoing optical rings

Installation Guidelines

  1. Ensure all power supplies are de-energized before mounting, wiring, or servicing the unit.
  2. Secure the Fieldbus Box using the two 3.5 mm mounting holes with M3 fasteners. Ensure the mounting surface is flat to avoid mechanical stress on the housing.
  3. Verify the maximum permissible bending radius for the fiber-optic cables during routing to prevent attenuation and transmission failures.
  4. Connect the incoming 24 V DC control voltage to the M8 male connector. If daisy-chaining, connect downstream modules to the M8 female connector.
  5. Install the 8 mm snap-type sensor connections, verifying that the sensors operate within the matching 24 V DC signal parameters.
  6. Power up the control supply and verify system communication status via the controller interface.

Replacement Recommendations

  1. Shut down and lock out the primary 24 V DC control voltage feeding the station.
  2. Disconnect the fiber-optic cables carefully, protecting the optical terminals from dust, debris, and oil contaminants.
  3. Unplug all 8 mm snap-type input sensors and label each corresponding channel position to prevent rewiring errors.
  4. Remove the M8 power cables and unscrew the mounting fasteners to detach the old module.
  5. Mount the replacement module, secure all connections as previously mapped, and run initial physical checks before re-energizing.
Loading product navigation…

What is the primary function of the BECKHOFF IP1010-B200?

The BECKHOFF IP1010-B200 is an 8-channel digital input Fieldbus Box designed to capture 24 V DC binary signals directly in the field and transmit them to a controller using the fiber-optic Lightbus network interface.

What connector types are used on the BECKHOFF IP1010-B200?

The BECKHOFF IP1010-B200 features 8 mm snap-type sockets for digital inputs, M8 4-pin sockets for control voltage distribution (one male feed and one female loop-through), and two specialized fiber-optic sockets for Lightbus communication.

Does the BECKHOFF IP1010-B200 require a protective enclosure?

No, the BECKHOFF IP1010-B200 does not require a control cabinet as its durable PA6 polyamide housing provides IP65, IP66, and IP67 protection ratings, permitting direct machinery installation in harsh conditions.

What are the fiber-optic connection requirements for the BECKHOFF IP1010-B200?

The BECKHOFF IP1010-B200 communicates via an APF plastic fiber-optic medium (1,000 um) with a maximum distance of 45 meters between stations and connects using plug model ZS1020-0010.

Is the sensor supply on the BECKHOFF IP1010-B200 protected?

Yes, the BECKHOFF IP1010-B200 provides a sensor supply sourced from the control voltage that is fully short-circuit proof with a maximum total current limit of 0.5 A.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.