The BECKHOFF IP2301-B528 is a decentralized industrial fieldbus module from the Fieldbus Box product family, designed for direct machine-level mounting without the need for a control cabinet. This device integrates four digital inputs and four digital outputs, providing reliable signal processing for automation systems operating in harsh industrial environments. It connects directly to a DeviceNet network and features an integrated T-connector for straightforward network topology implementation.

Engineered for decentralized architectures, the IP2301-B528 utilizes M8 connectors for process signal interfacing, reducing cabling overhead and streamlining installation on machine frames. Operating on a 24 V DC supply voltage, the module is equipped to handle standard industrial sensor and actuator requirements with a 0.5 A output current capability per channel. Its robust physical protection and direct-mount capability make it suitable for distributed control applications where space and environmental resilience are critical.

Features

  • Decentralized Fieldbus Box architecture designed for machine-level installation without a control cabinet
  • Integrated DeviceNet communication interface with a built-in T-connector for streamlined network cabling
  • 4 digital inputs and 4 digital outputs for standard discrete sensor and actuator connectivity
  • M8 connector technology for secure and compact process signal wiring
  • Standard 24 V DC system and peripheral supply voltage
  • 0.5 A switching capacity per digital output channel

Applications

  • Decentralized machine automation and modular plant engineering
  • Automated assembly lines and material handling systems requiring cabinet-free I/O distribution
  • Conveyor technology and sorting equipment with distributed sensor placement
  • Industrial machinery operating on DeviceNet communication networks

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2301-B528
Product Type Fieldbus Box
Fieldbus Protocol DeviceNet

Signal and I/O Specifications

Parameter Specification
Digital Inputs 4 channels
Digital Outputs 4 channels
Output Current 0.5 A per channel
Nominal Voltage 24 V DC
Filter / Response Time 3 ms

Electrical and Connection

Parameter Specification
Connection Technology (Signals) M8
Network Interface DeviceNet with integrated T-connector

Installation Guidelines

  1. Ensure that the system power and external supply voltages are fully de-energized before beginning any mechanical mounting or electrical wiring work.
  2. Inspect the IP2301-B528 housing, M8 connectors, and integrated T-connector for any visible transit damage or contamination.
  3. Mount the Fieldbus Box securely onto a flat machine surface or profile using the designated mounting holes to withstand operational vibration.
  4. Connect the DeviceNet network cable using the integrated T-connector, ensuring correct bus termination according to network requirements.
  5. Attach digital sensors and actuators to the M8 input and output ports, verifying correct pin assignments and cable shielding practices.
  6. Connect the 24 V DC power supply to the designated power terminals, checking polarity before restoring power.
  7. Power on the system and verify operational status via the device diagnostic LEDs and the master controller configuration.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What communication protocol does the BECKHOFF IP2301-B528 support?
The BECKHOFF IP2301-B528 communicates via the DeviceNet fieldbus protocol and includes an integrated T-connector for straightforward network integration.
How many I/O channels are available on the BECKHOFF IP2301-B528?
The BECKHOFF IP2301-B528 features 4 digital input channels and 4 digital output channels.
What is the rated output current for the digital outputs on the BECKHOFF IP2301-B528?
The digital outputs on the BECKHOFF IP2301-B528 are rated for a maximum current of 0.5 A per channel at 24 V DC.
What connection technology is used for process signals on the BECKHOFF IP2301-B528?
The BECKHOFF IP2301-B528 uses M8 connectors for connecting digital sensors and actuators directly to the module.
Reviews

IP2301-B528

Stock & lead time on request

Call
1 su 1

BECKHOFF IP2301-B528 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2301-B528

  • Country of origin:Germany

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF IP2301-B528 is a decentralized industrial fieldbus module from the Fieldbus Box product family, designed for direct machine-level mounting without the need for a control cabinet. This device integrates four digital inputs and four digital outputs, providing reliable signal processing for automation systems operating in harsh industrial environments. It connects directly to a DeviceNet network and features an integrated T-connector for straightforward network topology implementation.

Engineered for decentralized architectures, the IP2301-B528 utilizes M8 connectors for process signal interfacing, reducing cabling overhead and streamlining installation on machine frames. Operating on a 24 V DC supply voltage, the module is equipped to handle standard industrial sensor and actuator requirements with a 0.5 A output current capability per channel. Its robust physical protection and direct-mount capability make it suitable for distributed control applications where space and environmental resilience are critical.

Features

  • Decentralized Fieldbus Box architecture designed for machine-level installation without a control cabinet
  • Integrated DeviceNet communication interface with a built-in T-connector for streamlined network cabling
  • 4 digital inputs and 4 digital outputs for standard discrete sensor and actuator connectivity
  • M8 connector technology for secure and compact process signal wiring
  • Standard 24 V DC system and peripheral supply voltage
  • 0.5 A switching capacity per digital output channel

Applications

  • Decentralized machine automation and modular plant engineering
  • Automated assembly lines and material handling systems requiring cabinet-free I/O distribution
  • Conveyor technology and sorting equipment with distributed sensor placement
  • Industrial machinery operating on DeviceNet communication networks

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2301-B528
Product Type Fieldbus Box
Fieldbus Protocol DeviceNet

Signal and I/O Specifications

Parameter Specification
Digital Inputs 4 channels
Digital Outputs 4 channels
Output Current 0.5 A per channel
Nominal Voltage 24 V DC
Filter / Response Time 3 ms

Electrical and Connection

Parameter Specification
Connection Technology (Signals) M8
Network Interface DeviceNet with integrated T-connector

Installation Guidelines

  1. Ensure that the system power and external supply voltages are fully de-energized before beginning any mechanical mounting or electrical wiring work.
  2. Inspect the IP2301-B528 housing, M8 connectors, and integrated T-connector for any visible transit damage or contamination.
  3. Mount the Fieldbus Box securely onto a flat machine surface or profile using the designated mounting holes to withstand operational vibration.
  4. Connect the DeviceNet network cable using the integrated T-connector, ensuring correct bus termination according to network requirements.
  5. Attach digital sensors and actuators to the M8 input and output ports, verifying correct pin assignments and cable shielding practices.
  6. Connect the 24 V DC power supply to the designated power terminals, checking polarity before restoring power.
  7. Power on the system and verify operational status via the device diagnostic LEDs and the master controller configuration.
Loading product navigation…

What communication protocol does the BECKHOFF IP2301-B528 support?

The BECKHOFF IP2301-B528 communicates via the DeviceNet fieldbus protocol and includes an integrated T-connector for straightforward network integration.

How many I/O channels are available on the BECKHOFF IP2301-B528?

The BECKHOFF IP2301-B528 features 4 digital input channels and 4 digital output channels.

What is the rated output current for the digital outputs on the BECKHOFF IP2301-B528?

The digital outputs on the BECKHOFF IP2301-B528 are rated for a maximum current of 0.5 A per channel at 24 V DC.

What connection technology is used for process signals on the BECKHOFF IP2301-B528?

The BECKHOFF IP2301-B528 uses M8 connectors for connecting digital sensors and actuators directly to the module.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Modbus sulle reti di impianto: frame, registri e limiti di progettazione

Modbus è ancora ampiamente utilizzato perché il suo modello dati è semplice, non perché ogni implementazione lo sia. Questa guida spiega i frame, la mappatura dei registri, la temporizzazione, la...

All'interno della CPU del PLC: cicli di scansione, memoria e selezione

Una guida pratica di ingegneria al funzionamento della CPU di un PLC, dai cicli di scansione deterministici e dalle tabelle delle immagini degli I/O fino a memoria, comunicazioni, diagnostica,...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.