BECKHOFF

BECKHOFF IP3102-B318 PROFIBUS DP Fieldbus Box

SKU IP3102-B318

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP3102-B318
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The BECKHOFF IP3102-B318 is a specialized Fieldbus Box engineered for direct signal acquisition and communication within PROFIBUS DP networks. This industrial field module enables direct connections to machine architectures without the requirement of an electrical control cabinet, optimizing field-level deployment and decentralization.

Device configuration is supported directly through the master controller or via the BECKHOFF KS2000 software. The integration of DP-V1 extensions allows for expanded acyclic parameterization and diagnostics, providing clear, detailed status and diagnostic information back to the control station.

Designed for survival in demanding physical environments, the IP3102-B318 features a fully sealed enclosure rated to IP65, IP66, and IP67 standards. Standardized M8 and M12 connectors simplify wiring configurations, supporting high-speed transmission rates up to 12 Mbaud with automatic detection.

Features

  • Direct field installation capability, bypassing the need for a protective junction box
  • PROFIBUS DP communication with automatic baud rate detection up to 12 Mbaud
  • Supports DP-V1 extensions for flexible parameterization and device diagnostic tasks
  • Integrated M12 B-coded bus interface with built-in T-connector configuration
  • Standardized M8 power connections for direct power feed and downstream loop-through routing
  • Configuration options using the KS2000 interface or via the control system configuration utility

Applications

  • Distributed industrial control systems using PROFIBUS DP networking architectures
  • Decentralized input monitoring in machine building and processing lines
  • In-field instrumentation integration requiring ingress protection up to IP67

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP3102-B318
Product Type Fieldbus Box
Configuration Option Via KS2000 or the controller (DP-V1 extensions supported)

Communication and Interface

Parameter Specification
Bus Interface 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), integrated T-connector, B-coded
Data Transfer Rates Automatic detection up to 12 Mbaud
Data Transfer Medium Shielded copper cable, 2 x 0.25 mm²
Data Transfer Time Approximately 0.5 ms with 10 stations (each with 32-bit input and output)

Electrical and Power Supply

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Load Voltage According to I/O type
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 85 mA + current consumption of sensors (maximum 0.5 A)
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: No; Control voltage/inputs or outputs: According to I/O type

Mechanical and Environmental

Parameter Specification
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL

Connections / Interfaces

Interface or Terminal Function
Bus Connection (M12 Plug/Socket) PROFIBUS DP communication line, B-coded, featuring an integrated T-connector
Power Supply Feed (M8 Male) 24 V DC primary control voltage inlet
Power Supply Downstream (M8 Female) Loop-through supply connection to downstream Fieldbus Box modules

Installation Guidelines

  1. Verify that the physical BECKHOFF IP3102-B318 hardware matches the requirements of your control system layout before proceeding.
  2. Ensure all upstream and field-side electrical power sources are fully de-energized prior to mounting or connecting the unit.
  3. Securely mount the module on the machine structure or frame using suitable mounting fasteners, ensuring the physical installation orientation matches your application layout.
  4. Connect the PROFIBUS DP network cables to the B-coded M12 connections, utilizing the integrated T-connector path as required by the network topology.
  5. Verify and apply the 24 V DC control voltage to the 4-pin M8 male connector, and configure downstream daisy-chain power cabling if applicable.
  6. Verify the shielding and physical grounding parameters are correctly established for compliance with EMC immunity standards.
  7. Energize the system and use the master controller configuration software or KS2000 utility to establish baseline operational status and parameters.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What communication standard does the BECKHOFF IP3102-B318 use?
The BECKHOFF IP3102-B318 communicates using the PROFIBUS DP standard, with automatic detection of transfer rates up to 12 Mbaud, and supports DP-V1 extensions for advanced acyclic communication.
What is the environmental protection rating of the BECKHOFF IP3102-B318?
The BECKHOFF IP3102-B318 has an IP65, IP66, and IP67 protection rating (conforming to EN 60529), making it suitable for direct field mounting without requiring an electrical cabinet.
How is the BECKHOFF IP3102-B318 parameterized?
The BECKHOFF IP3102-B318 can be parameterized and configured either through the master controller system or by using the BECKHOFF KS2000 configuration software.
What types of power connections are used on the BECKHOFF IP3102-B318?
The BECKHOFF IP3102-B318 uses standard M8 connectors for power, featuring one 4-pin male socket for the incoming 24 V DC control power feed and one 4-pin female socket for routing downstream control power to additional modules.
Are there integrated routing solutions for the PROFIBUS network on the BECKHOFF IP3102-B318?
Yes, the BECKHOFF IP3102-B318 is equipped with one B-coded M12 socket and one B-coded M12 plug featuring an integrated tee-connector to simplify line-topology cabling.
Reviews

IP3102-B318

Stock & lead time on request

Call
1 su 1

BECKHOFF IP3102-B318 PROFIBUS DP Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP3102-B318

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF IP3102-B318 is a specialized Fieldbus Box engineered for direct signal acquisition and communication within PROFIBUS DP networks. This industrial field module enables direct connections to machine architectures without the requirement of an electrical control cabinet, optimizing field-level deployment and decentralization.

Device configuration is supported directly through the master controller or via the BECKHOFF KS2000 software. The integration of DP-V1 extensions allows for expanded acyclic parameterization and diagnostics, providing clear, detailed status and diagnostic information back to the control station.

Designed for survival in demanding physical environments, the IP3102-B318 features a fully sealed enclosure rated to IP65, IP66, and IP67 standards. Standardized M8 and M12 connectors simplify wiring configurations, supporting high-speed transmission rates up to 12 Mbaud with automatic detection.

Features

  • Direct field installation capability, bypassing the need for a protective junction box
  • PROFIBUS DP communication with automatic baud rate detection up to 12 Mbaud
  • Supports DP-V1 extensions for flexible parameterization and device diagnostic tasks
  • Integrated M12 B-coded bus interface with built-in T-connector configuration
  • Standardized M8 power connections for direct power feed and downstream loop-through routing
  • Configuration options using the KS2000 interface or via the control system configuration utility

Applications

  • Distributed industrial control systems using PROFIBUS DP networking architectures
  • Decentralized input monitoring in machine building and processing lines
  • In-field instrumentation integration requiring ingress protection up to IP67

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP3102-B318
Product Type Fieldbus Box
Configuration Option Via KS2000 or the controller (DP-V1 extensions supported)

Communication and Interface

Parameter Specification
Bus Interface 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), integrated T-connector, B-coded
Data Transfer Rates Automatic detection up to 12 Mbaud
Data Transfer Medium Shielded copper cable, 2 x 0.25 mm²
Data Transfer Time Approximately 0.5 ms with 10 stations (each with 32-bit input and output)

Electrical and Power Supply

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Load Voltage According to I/O type
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 85 mA + current consumption of sensors (maximum 0.5 A)
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: No; Control voltage/inputs or outputs: According to I/O type

Mechanical and Environmental

Parameter Specification
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL

Connections / Interfaces

Interface or Terminal Function
Bus Connection (M12 Plug/Socket) PROFIBUS DP communication line, B-coded, featuring an integrated T-connector
Power Supply Feed (M8 Male) 24 V DC primary control voltage inlet
Power Supply Downstream (M8 Female) Loop-through supply connection to downstream Fieldbus Box modules

Installation Guidelines

  1. Verify that the physical BECKHOFF IP3102-B318 hardware matches the requirements of your control system layout before proceeding.
  2. Ensure all upstream and field-side electrical power sources are fully de-energized prior to mounting or connecting the unit.
  3. Securely mount the module on the machine structure or frame using suitable mounting fasteners, ensuring the physical installation orientation matches your application layout.
  4. Connect the PROFIBUS DP network cables to the B-coded M12 connections, utilizing the integrated T-connector path as required by the network topology.
  5. Verify and apply the 24 V DC control voltage to the 4-pin M8 male connector, and configure downstream daisy-chain power cabling if applicable.
  6. Verify the shielding and physical grounding parameters are correctly established for compliance with EMC immunity standards.
  7. Energize the system and use the master controller configuration software or KS2000 utility to establish baseline operational status and parameters.
Loading product navigation…

What communication standard does the BECKHOFF IP3102-B318 use?

The BECKHOFF IP3102-B318 communicates using the PROFIBUS DP standard, with automatic detection of transfer rates up to 12 Mbaud, and supports DP-V1 extensions for advanced acyclic communication.

What is the environmental protection rating of the BECKHOFF IP3102-B318?

The BECKHOFF IP3102-B318 has an IP65, IP66, and IP67 protection rating (conforming to EN 60529), making it suitable for direct field mounting without requiring an electrical cabinet.

How is the BECKHOFF IP3102-B318 parameterized?

The BECKHOFF IP3102-B318 can be parameterized and configured either through the master controller system or by using the BECKHOFF KS2000 configuration software.

What types of power connections are used on the BECKHOFF IP3102-B318?

The BECKHOFF IP3102-B318 uses standard M8 connectors for power, featuring one 4-pin male socket for the incoming 24 V DC control power feed and one 4-pin female socket for routing downstream control power to additional modules.

Are there integrated routing solutions for the PROFIBUS network on the BECKHOFF IP3102-B318?

Yes, the BECKHOFF IP3102-B318 is equipped with one B-coded M12 socket and one B-coded M12 plug featuring an integrated tee-connector to simplify line-topology cabling.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...