The BECKHOFF KS3042 is a 2-channel analog input Bus Terminal designed to measure standard 0 to 20 mA current signals with 12-bit resolution within Beckhoff Bus Terminal I/O systems. Operating on the internal K-bus communication backplane, the KS3042 samples analog process variables from field devices and transfers digitized values with 500 V electrical isolation to the fieldbus coupler or industrial controller.

Equipped with a pluggable wiring assembly, the KS3042 enables fast maintenance and field replacement. The removable connector block allows the terminal housing to be swapped on the DIN rail without disconnecting individual signal wires, minimizing wiring errors and downtime. Field transducers can be powered directly from the module via the integrated 24 V DC power contacts, supporting compact 2-wire and 3-wire sensor wiring in control enclosures.

Features

  • Two single-ended analog input channels configured for 0 to 20 mA measurement loops
  • Pluggable spring-actuated wiring interface for fast servicing without rewiring individual field conductors
  • Integrated 24 V DC sensor power supply derived from the internal terminal power contacts
  • 12-bit analog-to-digital conversion with a sampling time of approximately 2 ms
  • 500 V electrical isolation between the field signal level and the K-bus backplane
  • Front-facing green Run LEDs for bus communication status and red Error LEDs for limit-stop and broken-wire diagnosis
  • Tool-free snap-on mounting on standard 35 mm DIN rails conforming to EN 60715

Connections / Interfaces

Interface or Terminal Function
Terminal 1 (+Input 1) Analog current input positive terminal, channel 1 (0 to 20 mA)
Terminal 2 (+24 V) Auxiliary 24 V DC sensor supply voltage (internally linked to terminal 6 and positive power contact)
Terminal 3 (0 V) 0 V ground reference potential for channel 1 (internally linked to terminal 7 and negative power contact)
Terminal 4 (Shield) Shield / protective earth (PE) connection (internally linked to terminal 8)
Terminal 5 (+Input 2) Analog current input positive terminal, channel 2 (0 to 20 mA)
Terminal 6 (+24 V) Auxiliary 24 V DC sensor supply voltage (internally linked to terminal 2 and positive power contact)
Terminal 7 (0 V) 0 V ground reference potential for channel 2 (internally linked to terminal 3 and negative power contact)
Terminal 8 (Shield) Shield / protective earth (PE) connection (internally linked to terminal 4)
Country of Origin Germany

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Part Number KS3042
Product Type 2-Channel Analog Input Bus Terminal
Product Family KS Series
Housing Material Polycarbonate
Design Form Terminal housing with pluggable wiring level
Mounting 35 mm DIN rail (EN 60715) with mechanical interlock
Side-by-Side Mounting Double slot and key connection
Protection Rating IP20
Installation Position Variable

Signal and I/O

Parameter Specification
Number of Inputs 2
Signal Current 0...20 mA
Input Circuit Technology Single-ended
Resolution 12 bit
Internal Resistance 80 ohms + diode voltage 0.7 V
Conversion Time Approx. 2 ms
Measurement Error < +/-0.3 % (relative to full scale value)
Surge Voltage Resistance Max. 35 V
Sensor Power Supply 24 V DC via power contacts

Electrical and Communication

Parameter Specification
Backplane Bus K-bus
Current Consumption K-bus Typ. 65 mA
Power Supply 24 V DC via power contacts
Current Consumption Power Contacts Load only
Current Load Power Contacts Max. 10 A
Electrical Isolation 500 V (K-bus / signal voltage)
Bit Width in Process Image Input: 2 x 16-bit data (2 x 8-bit control/status optional)
Configuration No address or configuration setting required

Wiring and Physical Properties

Parameter Specification
Wiring Technology Pluggable spring-actuation wiring level
Solid Conductor Cross-Section 0.08...1.5 mm2 (AWG 28...16)
Stranded Conductor Cross-Section 0.08...1.5 mm2 (AWG 28...16)
Flexible Conductor Cross-Section 0.14...1.5 mm2 (AWG 26...16)
Stripping Length 9...10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Net Weight Approx. 0.07 kg (70 g)

Environmental and Compliance

Parameter Specification
Operating Temperature -25...+60 degC
Storage Temperature -40...+85 degC
Relative Humidity 95 %, no condensation
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Approvals and Markings CE, UL, ATEX, DNV GL
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  • Always isolate electrical power to the Bus Coupler and power contacts before installing, removing, or servicing the module.
  • Snap the KS3042 directly onto a standard 35 mm DIN rail (EN 60715), engaging the side tongue-and-groove connections with adjacent Bus Terminals to ensure reliable contact of the power contacts and K-bus contacts.
  • To detach the pluggable wiring connector, release the connector locking tab and withdraw the pre-wired plug without releasing the individual conductors.
  • Use a flat-blade screwdriver to actuate the spring clamps when inserting solid, stranded, or ferruled conductors stripped to 9 to 10 mm.
  • Connect signal cable shields directly to shield terminals 4 or 8 to ensure optimal noise immunity in high-interference environments.

FAQ

What is the BECKHOFF KS3042?

The BECKHOFF KS3042 is a 2-channel analog input Bus Terminal designed to measure 0 to 20 mA single-ended current signals with 12-bit resolution and transmit digitized process data over the K-bus.

What is the difference between the BECKHOFF KS3042 and the KL3042?

The BECKHOFF KS3042 features a pluggable wiring connector that allows the entire wiring block to be removed from the terminal base without disconnecting individual wires, whereas the standard KL3042 uses fixed spring-clamp terminals.

Does the BECKHOFF KS3042 supply power to field sensors?

Yes, the BECKHOFF KS3042 provides integrated 24 V DC sensor supply points directly at terminals 2 and 6, which are powered internally through the terminal power contacts.

What do the diagnostic LEDs on the BECKHOFF KS3042 indicate?

The BECKHOFF KS3042 includes two green Run LEDs that illuminate during active data exchange with the Bus Coupler and two red Error LEDs that signal an overload condition, an over-range state exceeding 21.5 mA, or a broken wire.

What is the conversion time and resolution of the BECKHOFF KS3042?

The BECKHOFF KS3042 delivers 12-bit analog-to-digital conversion with a cycle conversion time of approximately 2 ms.

View all FAQs →

Quantità
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 su 1
Only 10 item(s) left in stock
Quantità
Visualizza dettagli completi
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Utilizzo di OPC UA | Connettività industriale con KEPServerEX

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Problemi di rete | Come e perché cambiare l’indirizzo IP del mio computer?

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Come i rischi delle polveri combustibili influiscono sul controllo automatizzato dei processi

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Comprendere gli statori Hairpin nei motori ad alta efficienza

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Dall’IT all’OT: esempio di piattaforma SCADA con Ansible

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Networking remoto: spiegazione delle VPN per gli ingegneri dei sistemi di controllo

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...