330730-080-00-00: 3300 XL 11 mm extension cable, configured with an 8.0 m cable length (Option 080), standard unarmored coaxial cable (Option 00), and no agency approvals (Option 00). This cable connects a 3300 XL 11 mm proximity probe to a 3300 XL 11 mm Proximitor sensor, establishing the necessary physical and electrical path for non-contact eddy-current displacement measurement. The total system length (probe plus extension cable) must equal the calibration length of the Proximitor sensor, which is typically 9.0 m when pairing this 8.0 m cable with a 1.0 m probe.
Unlike variants equipped with stainless steel armor (Option 01) or connector protectors (Option 02), this specific model utilizes standard unarmored FEP insulation. This provides a lightweight, highly flexible routing profile ideal for conduit runs and protected cable trays where mechanical abrasion and liquid submersion risks are minimal. The integrated gold-plated brass ClickLoc connectors prevent mechanical loosening under machinery vibration.
| Option Segment | Code on This SKU | Description / Selected Option |
|---|---|---|
| Orderable Part Number | 330730-080-00-00 | 3300 XL 11 mm Extension Cable |
| A - Cable Length Option | 080 | 8.0 meters (26.2 feet) |
| B - Connector and Cable Option | 00 | Standard cable |
| C - Agency Approval Option | 00 | Not required |
| Manufacturer | Bently Nevada |
| Model / Part Number | 330730-080-00-00 |
| Transducer System Compatibility | 3300 XL 11 mm Proximity Transducer System |
| Cable Length | 8.0 meters (26.2 feet) |
| Cable Construction | Standard unarmored FEP jacketed coaxial cable |
| Cable Impedance | 75 ohms |
| Center Conductor Resistance (R_core) | 0.6 +/- 0.2 ohms |
| Coaxial Conductor Resistance (R_jacket) | 2.0 +/- 0.5 ohms |
| Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
| Connector Material | Gold-plated brass |
| Connector Type | ClickLoc miniature coaxial connectors (one male, one female) |
| Minimum Bend Radius | 25.4 mm (1.0 in) |
| Tensile Strength (Maximum Rated) | 270 N (60 lb) at probe lead to extension cable connectors |
| Recommended Connection Torque | Finger tight |
| Maximum Connection Torque | 0.565 N-m (5 in-lb) |
| Extension Cable Weight (Typical) | 45 g/m (0.5 oz/ft) |
| Operating and Storage Temperature | -52 to +177 degC (-62 to +351 degF) |
| Relative Humidity Limit | 100% condensing, non-submersible when connectors are protected |
Ensure that the extension cable length (8.0 m) combined with the probe length (1.0 m) matches the calibrated length of the Proximitor sensor (9.0 m) for accurate calibration and linear range output. When routing the cable, avoid sharp bends and maintain a bend radius greater than 25.4 mm (1.0 in). Use insulated cable clamps or conduit to prevent the cable from chafing against metal structures. Tighten ClickLoc connectors to finger-tight status; do not exceed 0.565 N-m (5 in-lb) of torque. For humid or wet environments, the use of silicone tape or connector protectors is recommended at the probe-to-extension-cable connection to prevent moisture ingress (note: silicone tape is not recommended if exposed to turbine oil).
Global Express Shipping
Returns & Warranty



330730-080-00-00: 3300 XL 11 mm extension cable, configured with an 8.0 m cable length (Option 080), standard unarmored coaxial cable (Option 00), and no agency approvals (Option 00). This cable connects a 3300 XL 11 mm proximity probe to a 3300 XL 11 mm Proximitor sensor, establishing the necessary physical and electrical path for non-contact eddy-current displacement measurement. The total system length (probe plus extension cable) must equal the calibration length of the Proximitor sensor, which is typically 9.0 m when pairing this 8.0 m cable with a 1.0 m probe.
Unlike variants equipped with stainless steel armor (Option 01) or connector protectors (Option 02), this specific model utilizes standard unarmored FEP insulation. This provides a lightweight, highly flexible routing profile ideal for conduit runs and protected cable trays where mechanical abrasion and liquid submersion risks are minimal. The integrated gold-plated brass ClickLoc connectors prevent mechanical loosening under machinery vibration.
| Option Segment | Code on This SKU | Description / Selected Option |
|---|---|---|
| Orderable Part Number | 330730-080-00-00 | 3300 XL 11 mm Extension Cable |
| A - Cable Length Option | 080 | 8.0 meters (26.2 feet) |
| B - Connector and Cable Option | 00 | Standard cable |
| C - Agency Approval Option | 00 | Not required |
| Manufacturer | Bently Nevada |
| Model / Part Number | 330730-080-00-00 |
| Transducer System Compatibility | 3300 XL 11 mm Proximity Transducer System |
| Cable Length | 8.0 meters (26.2 feet) |
| Cable Construction | Standard unarmored FEP jacketed coaxial cable |
| Cable Impedance | 75 ohms |
| Center Conductor Resistance (R_core) | 0.6 +/- 0.2 ohms |
| Coaxial Conductor Resistance (R_jacket) | 2.0 +/- 0.5 ohms |
| Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
| Connector Material | Gold-plated brass |
| Connector Type | ClickLoc miniature coaxial connectors (one male, one female) |
| Minimum Bend Radius | 25.4 mm (1.0 in) |
| Tensile Strength (Maximum Rated) | 270 N (60 lb) at probe lead to extension cable connectors |
| Recommended Connection Torque | Finger tight |
| Maximum Connection Torque | 0.565 N-m (5 in-lb) |
| Extension Cable Weight (Typical) | 45 g/m (0.5 oz/ft) |
| Operating and Storage Temperature | -52 to +177 degC (-62 to +351 degF) |
| Relative Humidity Limit | 100% condensing, non-submersible when connectors are protected |
Ensure that the extension cable length (8.0 m) combined with the probe length (1.0 m) matches the calibrated length of the Proximitor sensor (9.0 m) for accurate calibration and linear range output. When routing the cable, avoid sharp bends and maintain a bend radius greater than 25.4 mm (1.0 in). Use insulated cable clamps or conduit to prevent the cable from chafing against metal structures. Tighten ClickLoc connectors to finger-tight status; do not exceed 0.565 N-m (5 in-lb) of torque. For humid or wet environments, the use of silicone tape or connector protectors is recommended at the probe-to-extension-cable connection to prevent moisture ingress (note: silicone tape is not recommended if exposed to turbine oil).
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|