The CJ1W-ID212 is a high-speed DC Input Unit designed for the Omron CJ-series PLC system. This unit provides 16 digital input points, engineered for applications requiring rapid signal acquisition. It operates at a nominal voltage of 24 VDC with a standard input current of 7 mA. The module is configured with 16 points per common, utilizing a removable terminal block for efficient wiring and maintenance. Occupying 1 word in the PLC process image, this unit is a space-effective solution for dense I/O requirements in automated machinery and production lines.

Features

  • 16 high-speed digital input points for fast signal processing
  • 24 VDC input voltage with 7 mA current draw
  • 16 points per common configuration
  • Removable terminal block for quick installation and replacement
  • Compact design allocating only 1 word of memory
  • Low current consumption (0.13 A at 5V)

Applications

  • High-speed production line monitoring
  • Fast-response sensor integration
  • Packaging and material handling automation
  • General-purpose digital signal interface for CJ-series PLC systems

Technical Specifications

Feature Specification
Manufacturer Omron
Part Number CJ1W-ID212
Device Type DC Input Unit
I/O Points 16 inputs (High speed)
Input Voltage 24 VDC
Input Current 7 mA
Commons 16 points, 1 common
External Connection Removable terminal block
Allocated Words 1 word
Current Consumption 0.13 A (at 5V)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Ensure the unit is securely seated on the CJ-series backplane. Lock the module using the sliders at the top and bottom to ensure a solid electrical connection.
  • Wiring: Use the removable terminal block for field wiring. Ensure wires are properly crimped or secured to prevent loose connections in high-vibration environments.
  • Commoning: Note that this unit uses 16 points per common. Ensure the common terminal is correctly wired to the 0V or 24V side of your power supply, depending on your PNP/NPN input sensor configuration.
  • Safety: Always disconnect power to the PLC system before installing or removing any I/O modules to prevent electrical arcs or damage to the backplane communication pins.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary advantage of the CJ1W-ID212 compared to standard input units?
The CJ1W-ID212 is specifically designated as a high-speed input unit, allowing for faster response times compared to standard DC input modules.
How many PLC memory words does this unit occupy?
The module occupies exactly 1 word in the process image of the PLC.
What type of connection is used for field wiring?
The unit features a removable terminal block, which allows for easy wiring and rapid module replacement without needing to disconnect individual wires.
Reviews

CJ1W-ID212

Stock & lead time on request

Call
1 su 1

CJ1W-ID212 | Omron | High-Speed DC Input Unit

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CJ1W-ID212

  • Country of origin:Japan

  • Product Type: DC Input Unit

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

The CJ1W-ID212 is a high-speed DC Input Unit designed for the Omron CJ-series PLC system. This unit provides 16 digital input points, engineered for applications requiring rapid signal acquisition. It operates at a nominal voltage of 24 VDC with a standard input current of 7 mA. The module is configured with 16 points per common, utilizing a removable terminal block for efficient wiring and maintenance. Occupying 1 word in the PLC process image, this unit is a space-effective solution for dense I/O requirements in automated machinery and production lines.

Features

  • 16 high-speed digital input points for fast signal processing
  • 24 VDC input voltage with 7 mA current draw
  • 16 points per common configuration
  • Removable terminal block for quick installation and replacement
  • Compact design allocating only 1 word of memory
  • Low current consumption (0.13 A at 5V)

Applications

  • High-speed production line monitoring
  • Fast-response sensor integration
  • Packaging and material handling automation
  • General-purpose digital signal interface for CJ-series PLC systems

Technical Specifications

Feature Specification
Manufacturer Omron
Part Number CJ1W-ID212
Device Type DC Input Unit
I/O Points 16 inputs (High speed)
Input Voltage 24 VDC
Input Current 7 mA
Commons 16 points, 1 common
External Connection Removable terminal block
Allocated Words 1 word
Current Consumption 0.13 A (at 5V)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Ensure the unit is securely seated on the CJ-series backplane. Lock the module using the sliders at the top and bottom to ensure a solid electrical connection.
  • Wiring: Use the removable terminal block for field wiring. Ensure wires are properly crimped or secured to prevent loose connections in high-vibration environments.
  • Commoning: Note that this unit uses 16 points per common. Ensure the common terminal is correctly wired to the 0V or 24V side of your power supply, depending on your PNP/NPN input sensor configuration.
  • Safety: Always disconnect power to the PLC system before installing or removing any I/O modules to prevent electrical arcs or damage to the backplane communication pins.

What is the primary advantage of the CJ1W-ID212 compared to standard input units?

The CJ1W-ID212 is specifically designated as a high-speed input unit, allowing for faster response times compared to standard DC input modules.

How many PLC memory words does this unit occupy?

The module occupies exactly 1 word in the process image of the PLC.

What type of connection is used for field wiring?

The unit features a removable terminal block, which allows for easy wiring and rapid module replacement without needing to disconnect individual wires.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Japan
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...