The EP1111-0000 is an EtherCAT Box from Beckhoff designed for decentralized signal acquisition and network identification within an EtherCAT topology. This module serves as a junction for the EtherCAT network, enabling the identification of specific EtherCAT groups. It features two shielded M8 sockets and supports standard 100BASE-TX communication, allowing for cable distances of up to 100 meters between stations. Built with an IP65/66/67 protection rating, the EP1111-0000 is suitable for harsh industrial environments where direct field mounting is required.

Features

  • EtherCAT protocol integration with identification functionality
  • 2 x M8 shielded sockets (screw type)
  • 100 Mbit/s data transfer rate
  • 100-meter range (100BASE-TX)
  • Ruggedized IP65/66/67 enclosure for field installation
  • No configuration required (plug-and-play operation)

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EP1111-0000
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded
Data Transfer Rate 100 Mbit/s
Max. Station Distance 100 m
Nominal Voltage 24 V DC (-15 %/+20 %)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65/66/67
Weight Approx. 165 g

Installation Guidelines

  • Mounting: The module is designed for decentralized installation directly on machinery. Use the integrated mounting points to secure the box to a vibration-resistant surface.
  • Cabling: Utilize shielded M8 EtherCAT cables. Ensure that cable lengths do not exceed the 100-meter limit between nodes to maintain signal integrity.
  • Environment: The device is rated for IP65/66/67. Ensure all M8 connections are fully tightened to maintain the moisture and dust seal.
  • Power: Ensure a stable 24 V DC power supply is connected, adhering to the voltage tolerance of -15%/+20%.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC immunity/emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Environmental: Conforms to EN 60529
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the EP1111-0000?
The module acts as a junction in an EtherCAT network, facilitating the identification of EtherCAT groups and network topology.
What is the maximum cable length for this module?
It supports a maximum distance of 100 meters between stations using 100BASE-TX cabling.
Does the EP1111-0000 require any software configuration?
No, the device does not require any manual configuration.
What is the protection rating of this EtherCAT box?
It is rated IP65/66/67, making it resistant to dust and water ingress for field installations.
Reviews

EP1111-0000

Stock & lead time on request

Call
1 su 1

EP1111-0000 | BECKHOFF | EtherCAT Box System Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP1111-0000

  • Country of origin:Germany

  • Product Type: EtherCAT Box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The EP1111-0000 is an EtherCAT Box from Beckhoff designed for decentralized signal acquisition and network identification within an EtherCAT topology. This module serves as a junction for the EtherCAT network, enabling the identification of specific EtherCAT groups. It features two shielded M8 sockets and supports standard 100BASE-TX communication, allowing for cable distances of up to 100 meters between stations. Built with an IP65/66/67 protection rating, the EP1111-0000 is suitable for harsh industrial environments where direct field mounting is required.

Features

  • EtherCAT protocol integration with identification functionality
  • 2 x M8 shielded sockets (screw type)
  • 100 Mbit/s data transfer rate
  • 100-meter range (100BASE-TX)
  • Ruggedized IP65/66/67 enclosure for field installation
  • No configuration required (plug-and-play operation)

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EP1111-0000
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded
Data Transfer Rate 100 Mbit/s
Max. Station Distance 100 m
Nominal Voltage 24 V DC (-15 %/+20 %)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65/66/67
Weight Approx. 165 g

Installation Guidelines

  • Mounting: The module is designed for decentralized installation directly on machinery. Use the integrated mounting points to secure the box to a vibration-resistant surface.
  • Cabling: Utilize shielded M8 EtherCAT cables. Ensure that cable lengths do not exceed the 100-meter limit between nodes to maintain signal integrity.
  • Environment: The device is rated for IP65/66/67. Ensure all M8 connections are fully tightened to maintain the moisture and dust seal.
  • Power: Ensure a stable 24 V DC power supply is connected, adhering to the voltage tolerance of -15%/+20%.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC immunity/emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Environmental: Conforms to EN 60529

What is the primary function of the EP1111-0000?

The module acts as a junction in an EtherCAT network, facilitating the identification of EtherCAT groups and network topology.

What is the maximum cable length for this module?

It supports a maximum distance of 100 meters between stations using 100BASE-TX cabling.

Does the EP1111-0000 require any software configuration?

No, the device does not require any manual configuration.

What is the protection rating of this EtherCAT box?

It is rated IP65/66/67, making it resistant to dust and water ingress for field installations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...