General Electric

General Electric IS420UCSBH3A Mark VIe UCSB Controller Module

SKU IS420UCSBH3A

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric
  • Product No.: IS420UCSBH3A
  • Origin United States
  • Product Type: UCSB Controller Module
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 1.315 kg
  • Dimensions: 6.4 in x 8.1 in x 1.4 in
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The IS420UCSBH3A is a standalone processor module designed for high-performance turbine control within the General Electric Mark VIe Series ecosystem. This UCSB controller module executes dedicated application code to manage gas, steam, and wind turbine automated drive assemblies, providing a unified control architecture for modern power generation and industrial automation. Unlike legacy hardware platforms like the Mark V Series, which were restricted primarily to gas and steam assets, this module supports integrated wind turbine applications alongside traditional thermal units.

The hardware architecture integrates a processing core, dual network interfaces, and localized diagnostic functionality without relying on a cooling fan or volatile backup batteries. It incorporates proprietary Speedtronic control system technology, operating as the computational hub for the execution of control loops, input/output data processing, and critical protection logic.

Features

  • Dual-redundant or single-controller configuration options for flexible system architecture.
  • Fanless thermal design eliminates mechanical wear components to maximize uptime.
  • Batteryless operation reduces maintenance intervals and environmental waste.
  • Jumper-free hardware design simplifies field commissioning and replacement procedures.
  • Front-panel diagnostic LEDs provide direct visual tracking of unit status and runtime health.
  • Native integration with MarkVIe and MarkStat automation platforms.

Applications

  • General Electric gas turbine automation and thermal control systems.
  • Utility-scale steam turbine governor and auxiliary management.
  • Integrated wind turbine automated drive assemblies and pitch controls.
  • High-availability industrial process applications utilizing the Speedtronic platform.

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model Number IS420UCSBH3A
Functional Abbreviation UCSB
Processor Type 1200 MHz EP80579 Intel
Input Voltage 24/28 VDC
Wire Sizes 28 to 16 AWG
Operating Temperature 0 to 65 degC
Weight approx. 2.9 lbs
Dimensions (H x W x D) 6.4 in x 8.1 in x 1.4 in
Country of Origin United States (Salem, Virginia factory)
Product Revision A-rated functional style revision

Interface Mapping

Front Plate LED Color Function / Operational State
OT Amber Internal components have surpassed the recommended thermal limit.
ON Varied Indicates the real-time status of the controller restoration process.
DC Solid Green The module has been designated and chosen as the primary controller.
ONL Solid Green The controller is online and actively running the application code.

Installation Guidelines

  • Hazardous Area Precautions: Ensure all environmental controls match Class I, Division 2 specifications prior to mounting or servicing the device. Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.
  • Thermal Management: Mount the unit vertically within the designated enclosure to optimize natural convective airflow, ensuring ambient temperatures around the chassis remain within the 0 to 65 degC operating envelope.
  • Wiring Requirements: Secure all field and power connections using approved wiring gauges ranging from 28 to 16 AWG. Ensure terminal screws are torqued according to control panel specifications.
  • Hardware Configuration: The module features a jumper-free layout; all configuration and network address assignments are managed directly via the engineering software platform during commissioning.

Compliance and Certifications

  • Class I, Division 2, Groups A, B, C, D location standards.
  • ANSI/ISA-12.12.01-2015 * CAN/CSA-C22.2 No. 213-15
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What does a solid amber OT LED indicate on the front panel?
A solid amber OT LED indicates that the internal components of the controller have surpassed the recommended operational thermal limit.
Does this controller module require an external backup battery?
No. The hardware architecture operates without a volatile backup battery, eliminating periodic battery maintenance and replacement schedules.
Which standards must be met when mounting this module in hazardous locations?
When installed in Class I, Division 2, Groups A, B, C, or D locations, compliance with ANSI/ISA-12.12.01-2015 or CAN/CSA-C22.2 No. 213-15 standards is required.
Reviews

IS420UCSBH3A

Stock & lead time on request

Call
1 su 3

General Electric IS420UCSBH3A Mark VIe UCSB Controller Module

Only 4 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS420UCSBH3A

  • Country of origin:United States

  • Product Type: UCSB Controller Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1315g

  • Dimensions: 6.4 in x 8.1 in x 1.4 in

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The IS420UCSBH3A is a standalone processor module designed for high-performance turbine control within the General Electric Mark VIe Series ecosystem. This UCSB controller module executes dedicated application code to manage gas, steam, and wind turbine automated drive assemblies, providing a unified control architecture for modern power generation and industrial automation. Unlike legacy hardware platforms like the Mark V Series, which were restricted primarily to gas and steam assets, this module supports integrated wind turbine applications alongside traditional thermal units.

The hardware architecture integrates a processing core, dual network interfaces, and localized diagnostic functionality without relying on a cooling fan or volatile backup batteries. It incorporates proprietary Speedtronic control system technology, operating as the computational hub for the execution of control loops, input/output data processing, and critical protection logic.

Features

  • Dual-redundant or single-controller configuration options for flexible system architecture.
  • Fanless thermal design eliminates mechanical wear components to maximize uptime.
  • Batteryless operation reduces maintenance intervals and environmental waste.
  • Jumper-free hardware design simplifies field commissioning and replacement procedures.
  • Front-panel diagnostic LEDs provide direct visual tracking of unit status and runtime health.
  • Native integration with MarkVIe and MarkStat automation platforms.

Applications

  • General Electric gas turbine automation and thermal control systems.
  • Utility-scale steam turbine governor and auxiliary management.
  • Integrated wind turbine automated drive assemblies and pitch controls.
  • High-availability industrial process applications utilizing the Speedtronic platform.

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model Number IS420UCSBH3A
Functional Abbreviation UCSB
Processor Type 1200 MHz EP80579 Intel
Input Voltage 24/28 VDC
Wire Sizes 28 to 16 AWG
Operating Temperature 0 to 65 degC
Weight approx. 2.9 lbs
Dimensions (H x W x D) 6.4 in x 8.1 in x 1.4 in
Country of Origin United States (Salem, Virginia factory)
Product Revision A-rated functional style revision

Interface Mapping

Front Plate LED Color Function / Operational State
OT Amber Internal components have surpassed the recommended thermal limit.
ON Varied Indicates the real-time status of the controller restoration process.
DC Solid Green The module has been designated and chosen as the primary controller.
ONL Solid Green The controller is online and actively running the application code.

Installation Guidelines

  • Hazardous Area Precautions: Ensure all environmental controls match Class I, Division 2 specifications prior to mounting or servicing the device. Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous.
  • Thermal Management: Mount the unit vertically within the designated enclosure to optimize natural convective airflow, ensuring ambient temperatures around the chassis remain within the 0 to 65 degC operating envelope.
  • Wiring Requirements: Secure all field and power connections using approved wiring gauges ranging from 28 to 16 AWG. Ensure terminal screws are torqued according to control panel specifications.
  • Hardware Configuration: The module features a jumper-free layout; all configuration and network address assignments are managed directly via the engineering software platform during commissioning.

Compliance and Certifications

  • Class I, Division 2, Groups A, B, C, D location standards.
  • ANSI/ISA-12.12.01-2015 * CAN/CSA-C22.2 No. 213-15

What does a solid amber OT LED indicate on the front panel?

A solid amber OT LED indicates that the internal components of the controller have surpassed the recommended operational thermal limit.

Does this controller module require an external backup battery?

No. The hardware architecture operates without a volatile backup battery, eliminating periodic battery maintenance and replacement schedules.

Which standards must be met when mounting this module in hazardous locations?

When installed in Class I, Division 2, Groups A, B, C, or D locations, compliance with ANSI/ISA-12.12.01-2015 or CAN/CSA-C22.2 No. 213-15 standards is required.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...