Honeywell

Honeywell 2108B2101 Searchpoint Optima Plus Infrared Gas Detector

SKU 2108B2101

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 2108B2101
  • Origin United States
  • Product Type: Infrared Gas Detectors
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Monitoring hazardous industrial environments requires reliable and continuous gas detection, which is provided by the Honeywell 2108B2101 infrared hydrocarbon gas detector. Operating as part of the Searchpoint Optima Plus series, this point gas detector utilizes dual-wavelength infrared absorption technology to deliver fast and accurate gas monitoring in potentially explosive atmospheres. Designed for challenging field conditions, the device is highly resistant to common sensor poisons such as silicones, sulfur, and lead, ensuring long-term operational stability and minimizing maintenance requirements.

The 2108B2101 detector features a robust 316 stainless steel housing that provides exceptional protection against harsh weather, seawater, and mechanical impacts. Its optical design features a heated optical chamber to prevent condensation, maintaining high measurement integrity even during rapid temperature fluctuations. This instrument integrates into existing industrial safety infrastructures via a standard 3-wire 4-20mA output configuration, making it compatible with a wide range of PLCs, DCSs, and safety controllers.

Features

  • Dual-wavelength infrared detection technology ensures fail-safe operation and high stability.
  • Immunity to catalytic poisons including silicones, sulfur, halogens, and heavy metals.
  • Fast speed of response (T50/T90) for rapid leak detection.
  • Heated optics eliminate the risk of condensation and optical drift.
  • Robust 316 stainless steel construction suitable for offshore and onshore environments.
  • Low power consumption design with local diagnostic capabilities.
  • Capable of operating in completely inert atmospheres where catalytic sensors fail.

Applications

  • Offshore oil and gas production platforms
  • Onshore petrochemical refineries and processing plants
  • Gas transmission stations and compressor facilities
  • Chemical manufacturing plants
  • Wastewater treatment facilities with hydrocarbon hazards
  • Power generation sites utilizing natural gas

Technical Specifications

Manufacturer Honeywell
Part Number / Model 2108B2101
Series Searchpoint Optima Plus
Detection Method Infrared absorption (dual wavelength, multi-channel)
Gases Detected Hydrocarbons (calibrated for specific target gases)
Signal Output Analog 4-20mA (source or sink options)
Housing Material 316 Stainless steel
Operating Voltage 18 to 32 VDC
Power Consumption Under 4.5 W (typical)
Operating Temperature -40 to +65 degC
Enclosure Rating IP66 / IP67
Cable Entry M25 thread options

Installation Guidelines

To ensure optimal performance and safety, follow these fundamental installation principles:

  • Mounting Orientation: Mount the gas detector horizontally to prevent dust, water, or debris from accumulating on the optical window.
  • Positioning: Place the detector near potential leak sources or at locations where hydrocarbon vapors are likely to accumulate, taking gas density and local airflow patterns into account.
  • Wiring and Grounding: Ensure the device is connected using shielded cable to prevent electromagnetic interference. Properly ground the housing in accordance with local explosion-proof wiring codes.
  • Hazardous Areas: Maintain the integrity of explosion-proof cable glands and conduit seals to preserve the certified safety rating of the installation.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary sensing technology used in the Honeywell 2108B2101?
The Honeywell 2108B2101 uses dual-wavelength infrared absorption technology, which provides fail-safe monitoring and high resistance to environmental factors and poisoning.
Does the 2108B2101 suffer from sensor poisoning like catalytic bead detectors?
No, infrared gas detectors like the Searchpoint Optima Plus are completely immune to common catalytic poisons such as silicones, sulfur, lead, and chlorinated compounds.
What is the operating temperature range for the Honeywell 2108B2101?
The detector is designed to operate reliably within a temperature range of -40 to +65 degC.
Can this gas detector operate in oxygen-deficient or inert atmospheres?
Yes, because infrared detection does not require oxygen to function, the 2108B2101 can monitor hydrocarbon concentrations in inert and oxygen-depleted environments.
Reviews

2108B2101

Stock & lead time on request

Call
1 su 1

Honeywell 2108B2101 Searchpoint Optima Plus Infrared Gas Detector

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 2108B2101

  • Country of origin:United States

  • Product Type: Infrared Gas Detectors

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Monitoring hazardous industrial environments requires reliable and continuous gas detection, which is provided by the Honeywell 2108B2101 infrared hydrocarbon gas detector. Operating as part of the Searchpoint Optima Plus series, this point gas detector utilizes dual-wavelength infrared absorption technology to deliver fast and accurate gas monitoring in potentially explosive atmospheres. Designed for challenging field conditions, the device is highly resistant to common sensor poisons such as silicones, sulfur, and lead, ensuring long-term operational stability and minimizing maintenance requirements.

The 2108B2101 detector features a robust 316 stainless steel housing that provides exceptional protection against harsh weather, seawater, and mechanical impacts. Its optical design features a heated optical chamber to prevent condensation, maintaining high measurement integrity even during rapid temperature fluctuations. This instrument integrates into existing industrial safety infrastructures via a standard 3-wire 4-20mA output configuration, making it compatible with a wide range of PLCs, DCSs, and safety controllers.

Features

  • Dual-wavelength infrared detection technology ensures fail-safe operation and high stability.
  • Immunity to catalytic poisons including silicones, sulfur, halogens, and heavy metals.
  • Fast speed of response (T50/T90) for rapid leak detection.
  • Heated optics eliminate the risk of condensation and optical drift.
  • Robust 316 stainless steel construction suitable for offshore and onshore environments.
  • Low power consumption design with local diagnostic capabilities.
  • Capable of operating in completely inert atmospheres where catalytic sensors fail.

Applications

  • Offshore oil and gas production platforms
  • Onshore petrochemical refineries and processing plants
  • Gas transmission stations and compressor facilities
  • Chemical manufacturing plants
  • Wastewater treatment facilities with hydrocarbon hazards
  • Power generation sites utilizing natural gas

Technical Specifications

Manufacturer Honeywell
Part Number / Model 2108B2101
Series Searchpoint Optima Plus
Detection Method Infrared absorption (dual wavelength, multi-channel)
Gases Detected Hydrocarbons (calibrated for specific target gases)
Signal Output Analog 4-20mA (source or sink options)
Housing Material 316 Stainless steel
Operating Voltage 18 to 32 VDC
Power Consumption Under 4.5 W (typical)
Operating Temperature -40 to +65 degC
Enclosure Rating IP66 / IP67
Cable Entry M25 thread options

Installation Guidelines

To ensure optimal performance and safety, follow these fundamental installation principles:

  • Mounting Orientation: Mount the gas detector horizontally to prevent dust, water, or debris from accumulating on the optical window.
  • Positioning: Place the detector near potential leak sources or at locations where hydrocarbon vapors are likely to accumulate, taking gas density and local airflow patterns into account.
  • Wiring and Grounding: Ensure the device is connected using shielded cable to prevent electromagnetic interference. Properly ground the housing in accordance with local explosion-proof wiring codes.
  • Hazardous Areas: Maintain the integrity of explosion-proof cable glands and conduit seals to preserve the certified safety rating of the installation.

What is the primary sensing technology used in the Honeywell 2108B2101?

The Honeywell 2108B2101 uses dual-wavelength infrared absorption technology, which provides fail-safe monitoring and high resistance to environmental factors and poisoning.

Does the 2108B2101 suffer from sensor poisoning like catalytic bead detectors?

No, infrared gas detectors like the Searchpoint Optima Plus are completely immune to common catalytic poisons such as silicones, sulfur, lead, and chlorinated compounds.

What is the operating temperature range for the Honeywell 2108B2101?

The detector is designed to operate reliably within a temperature range of -40 to +65 degC.

Can this gas detector operate in oxygen-deficient or inert atmospheres?

Yes, because infrared detection does not require oxygen to function, the 2108B2101 can monitor hydrocarbon concentrations in inert and oxygen-depleted environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.