Honeywell

Honeywell 2MLQ-TR4B-CC Transistor Output Module

SKU 2MLQ-TR4B-CC

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 2MLQ-TR4B-CC
  • Origin United States
  • Product Type: Transistor Output Module
  • Payment: T/T, Western Union
  • Weight: 0.1 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

The Honeywell 2MLQ-TR4B-CC is a high-density Transistor Output Module designed for precision switching of field devices within industrial control systems. This module features 32 output points, providing efficient discrete signal control for automation tasks. It utilizes photo coupler isolation to ensure a high level of protection between the internal control circuitry and external field devices, preventing electrical interference and protecting the controller from field-side transients.

Features

  • High Channel Density: 32 independent transistor output points for streamlined control
  • Electrical Protection: Photo coupler isolation for enhanced system safety and noise immunity
  • Fast Switching: Transistor-based outputs suitable for high-frequency operations
  • Compact Design: Lightweight architecture for efficient space utilization in control cabinets

Applications

  • High-speed industrial machinery control
  • Actuation of solenoid valves and small relays
  • Discrete output signaling for PLC and DCS architectures
  • Automated assembly and material handling systems

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 2MLQ-TR4B-CC
Product Type Transistor Output Module
Output Points 32 points
Isolation Method Photo coupler isolation
Net Weight 0.1 kg
Shipping Weight 2.0 kg

Installation Guidelines

  • Mounting: Ensure the module is firmly inserted into the designated I/O base slot, confirming the locking mechanisms are fully engaged.
  • Wiring: Utilize properly rated wire for the load requirements of each output point; keep high-current output lines separate from low-voltage signal lines.
  • Grounding: Always verify that the I/O base is properly grounded to the system cabinet earth to maintain the efficacy of the photo coupler isolation.
  • Protection: Although the module includes internal isolation, external suppression (such as flyback diodes) is recommended when driving inductive loads to extend the lifespan of the output transistors.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How many outputs does the 2MLQ-TR4B-CC provide?
This module features 32 independent transistor output points.
What is the benefit of photo coupler isolation?
Photo coupler isolation provides electrical separation between the field wiring and the internal controller circuitry, protecting the module from noise and voltage transients.
Is this module suitable for inductive loads?
Yes, but external suppression, such as a flyback diode, is strongly recommended when switching inductive loads like solenoids to protect the internal transistors.
Reviews

2MLQ-TR4B-CC

Stock & lead time on request

Call
1 su 1

Honeywell 2MLQ-TR4B-CC Transistor Output Module

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 2MLQ-TR4B-CC

  • Country of origin:United States

  • Product Type: Transistor Output Module

  • Payment: T/T, Western Union

  • Weight: 100g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

The Honeywell 2MLQ-TR4B-CC is a high-density Transistor Output Module designed for precision switching of field devices within industrial control systems. This module features 32 output points, providing efficient discrete signal control for automation tasks. It utilizes photo coupler isolation to ensure a high level of protection between the internal control circuitry and external field devices, preventing electrical interference and protecting the controller from field-side transients.

Features

  • High Channel Density: 32 independent transistor output points for streamlined control
  • Electrical Protection: Photo coupler isolation for enhanced system safety and noise immunity
  • Fast Switching: Transistor-based outputs suitable for high-frequency operations
  • Compact Design: Lightweight architecture for efficient space utilization in control cabinets

Applications

  • High-speed industrial machinery control
  • Actuation of solenoid valves and small relays
  • Discrete output signaling for PLC and DCS architectures
  • Automated assembly and material handling systems

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 2MLQ-TR4B-CC
Product Type Transistor Output Module
Output Points 32 points
Isolation Method Photo coupler isolation
Net Weight 0.1 kg
Shipping Weight 2.0 kg

Installation Guidelines

  • Mounting: Ensure the module is firmly inserted into the designated I/O base slot, confirming the locking mechanisms are fully engaged.
  • Wiring: Utilize properly rated wire for the load requirements of each output point; keep high-current output lines separate from low-voltage signal lines.
  • Grounding: Always verify that the I/O base is properly grounded to the system cabinet earth to maintain the efficacy of the photo coupler isolation.
  • Protection: Although the module includes internal isolation, external suppression (such as flyback diodes) is recommended when driving inductive loads to extend the lifespan of the output transistors.

How many outputs does the 2MLQ-TR4B-CC provide?

This module features 32 independent transistor output points.

What is the benefit of photo coupler isolation?

Photo coupler isolation provides electrical separation between the field wiring and the internal controller circuitry, protecting the module from noise and voltage transients.

Is this module suitable for inductive loads?

Yes, but external suppression, such as a flyback diode, is strongly recommended when switching inductive loads like solenoids to protect the internal transistors.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...