Honeywell

Honeywell 51305072-300 TDC 3000 CLCN B Cable Interface Converter Board

SKU 51305072-300

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 51305072-300
  • Origin United States
  • Product Type: Communication Boards
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 300 mm x 200 mm x 50 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 51305072-300 TDC 3000 CLCN B Cable Interface Converter Board

Quantità

Product Description

Description

The Honeywell 51305072-300 is a CLCN B Cable Interface Converter Board designed for use in TDC 3000X systems and Enhanced Programmable Logic Controller Gateway (EPLCG) hardware. The board serves as a rear cable interface adapter in CE Compliant Dual Node module configurations. Installed in slot 1 of a 3-slot node Dual Node module alongside a K2LCN processor board (such as 51401288-100), the 51305072-300 provides physical connectivity to the Local Control Network (LCN) coaxial cable architecture.

Features

  • CE Compliant Hardware: Meets European Union EMC and Health and Safety Directives.
  • Node Slot Compatibility: Designed for installation in rear slot 1 of 3-slot node Dual Node module assemblies.
  • LCN Architecture Support: Functions as a dedicated Local Control Network Cable Interface Converter Board (CLCN B).

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Part Number 51305072-300
Board Name CLCN B Cable Interface Converter Board
Compliance CE Compliant
Module Slot Assignment Slot 1 (Rear) in 3-slot Dual Node Module
Associated Front Card K2LCN (P/N 51401288-100)
Associated Faceplate CLCN B Faceplate (P/N 51304982-100)
Replacement Level Optimum Replaceable Unit (ORU)

Installation Guidelines

  • Power Precaution: Do not remove or replace circuit boards while the power is ON.
  • ESD Safety: Observe standard Electrostatic Discharge (ESD) procedures when handling or transporting the board.
  • Physical Location: Mount the 51305072-300 board into the rear of slot 1 of a 3-slot Dual Node module cage directly behind its associated front processor card.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the Honeywell 51305072-300 used for?
The Honeywell 51305072-300 is a CLCN B Cable Interface Converter Board used as a rear interface card in CE Compliant Dual Node modules to connect to the Local Control Network.
Which system does the Honeywell 51305072-300 belong to?
The module belongs to the Honeywell TDC 3000 system and is used within Enhanced Programmable Logic Controller Gateway (EPLCG) Dual Node module hardware.
Where is the 51305072-300 installed in the chassis?
It is installed in the rear of slot 1 in a 3-slot node Dual Node module assembly.
Which front board operates alongside the 51305072-300?
The 51305072-300 operates in slot 1 paired with a K2LCN front processor board (P/N 51401288-100).
Reviews

51305072-300

Stock & lead time on request

Call
1 su 1

Honeywell 51305072-300 TDC 3000 CLCN B Cable Interface Converter Board

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51305072-300

  • Country of origin:United States

  • Product Type: Communication Boards

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 300 mm x 200 mm x 50 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell 51305072-300 is a CLCN B Cable Interface Converter Board designed for use in TDC 3000X systems and Enhanced Programmable Logic Controller Gateway (EPLCG) hardware. The board serves as a rear cable interface adapter in CE Compliant Dual Node module configurations. Installed in slot 1 of a 3-slot node Dual Node module alongside a K2LCN processor board (such as 51401288-100), the 51305072-300 provides physical connectivity to the Local Control Network (LCN) coaxial cable architecture.

Features

  • CE Compliant Hardware: Meets European Union EMC and Health and Safety Directives.
  • Node Slot Compatibility: Designed for installation in rear slot 1 of 3-slot node Dual Node module assemblies.
  • LCN Architecture Support: Functions as a dedicated Local Control Network Cable Interface Converter Board (CLCN B).

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Part Number 51305072-300
Board Name CLCN B Cable Interface Converter Board
Compliance CE Compliant
Module Slot Assignment Slot 1 (Rear) in 3-slot Dual Node Module
Associated Front Card K2LCN (P/N 51401288-100)
Associated Faceplate CLCN B Faceplate (P/N 51304982-100)
Replacement Level Optimum Replaceable Unit (ORU)

Installation Guidelines

  • Power Precaution: Do not remove or replace circuit boards while the power is ON.
  • ESD Safety: Observe standard Electrostatic Discharge (ESD) procedures when handling or transporting the board.
  • Physical Location: Mount the 51305072-300 board into the rear of slot 1 of a 3-slot Dual Node module cage directly behind its associated front processor card.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 51305072-300 TDC 3000 CLCN B Cable Interface Converter Board

What is the Honeywell 51305072-300 used for?

The Honeywell 51305072-300 is a CLCN B Cable Interface Converter Board used as a rear interface card in CE Compliant Dual Node modules to connect to the Local Control Network.

Which system does the Honeywell 51305072-300 belong to?

The module belongs to the Honeywell TDC 3000 system and is used within Enhanced Programmable Logic Controller Gateway (EPLCG) Dual Node module hardware.

Where is the 51305072-300 installed in the chassis?

It is installed in the rear of slot 1 in a 3-slot node Dual Node module assembly.

Which front board operates alongside the 51305072-300?

The 51305072-300 operates in slot 1 paired with a K2LCN front processor board (P/N 51401288-100).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.