Honeywell

Honeywell 8C-TPOXA1 51307153-175 Experion Series 8 PROFIBUS Gateway IOTA, Coated

SKU 8C-TPOXA1 51307153-175

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 8C-TPOXA1 51307153-175
  • Origin United States
  • Product Type: IOTA gateway PROFIBUS
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.6 kg
  • Dimensions: 160 x 310 x 50 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 8C-TPOXA1 51307153-175 Experion Series 8 PROFIBUS Gateway IOTA, Coated

Quantità

Product Description

Description

The Honeywell 8C-TPOXA1 (Part Number 51307153-175) is a conformal coated Input/Output Termination Assembly (IOTA) designed specifically for the Honeywell Experion LX Series 8 Distributed Control System (DCS) platform. It serves as the physical mounting and wiring interface for the Honeywell 8C-IP0102 PROFIBUS Gateway Module (PGM), enabling fieldbus communication links between field instrumentation and the controller system.

This IOTA functions as the vital connection point for external field communication cables, power distribution, and system-level interface routing. Built with factory conformal coating, the 8C-TPOXA1 is engineered to withstand harsh industrial processing environments, preventing board-level contamination and corrosion.

Features

  • Dedicated Gateway Interface: Designed specifically to host the 8C-IP0102 PROFIBUS Gateway Module within the Experion Series 8 architecture.
  • Conformal Coating Protection: Coated circuit board construction provides enhanced resilience against industrial airborne pollutants and moisture.
  • Integrated Connectivity: Features dual FTE-A and FTE-B Ethernet link RJ-45 ports along with PBLink network interface terminals.
  • Addressing Capability: Incorporates three rotary FTE Device Index switches directly on the assembly for hardware node identification.
  • System Bus Isolation: Features grounded mounting interface hardware connecting to the system COM bus bar for proper ground integrity.

Applications

  • Process Control Fieldbus Integration: Hosts PROFIBUS gateway modules connecting smart instrumentation to Experion Series 8 DCS controllers.
  • Corrosive Processing Environments: Ideal for installation in chemical, oil and gas, or manufacturing facilities requiring conformal coated control hardware.
  • Industrial Network Subsystems: Interfacing field devices with high-availability control network topologies.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 8C-TPOXA1
Part Number 51307153-175
Product Type PROFIBUS Gateway IOTA
Series Experion LX Series 8
Coating Conformal Coated
Operating Voltage 24 VDC
Max Current Rating 20 A (Header board subsystem)
Ambient Operating Temperature 0 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Operating Humidity 5% to 95% RH (non-condensing)
Vibration 10–57 Hz (0.075 mm displacement), 57–150 Hz (1 G load)
Mechanical Shock 15 G in 3 axes (11 ms duration)

Connections / Interfaces

Interface / Connector Function
FTE-A (RJ-45) Primary Fault Tolerant Ethernet network link connection
FTE-B (RJ-45) Secondary Fault Tolerant Ethernet network link connection
PBLink Ports PROFIBUS network cable terminal connections
Device Index Switches Three rotary switches for setting FTE hardware network node address
System COM Ground Ground connection interface to cabinet COM bus bar

Installation Guidelines

  1. Verify that the system power supply is isolated or the system is off-process before mounting.
  2. Confirm the IOTA hardware part number and ensure the conformal coating matches installation requirements.
  3. Mount the IOTA onto the cabinet channel rail using the dedicated screws, washers, and spacers.
  4. Tighten the grounding screw on the right side of the IOTA to secure connection to the cabinet COM bus bar.
  5. Ensure the four main mounting screws are tightened uniformly without causing board distortion.
  6. Connect the yellow Cat5 cable to the FTE-A connector and green Cat5 cable to the FTE-B connector.
  7. Terminate PBLink fieldbus cables to their designated connector points.

Configuration and Replacement Recommendations

  • Address Verification: Set the three rotary FTE Device Index switches to match the exact node address of the original unit prior to powering up.
  • Module Seating: When installing the 8C-IP0102 gateway module onto the IOTA, ensure board edge connectors mate cleanly before tightening retention screws.
  • System Load: After hardware replacement, perform a "Load with Contents" operation from Control Builder to update operational parameters.

Compliance and Certifications

  • Low Voltage Directive (LVD): EN 61010-1:2010
  • EMC Directive: EN 61326-1:2006, IEC 61326-1:2005
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What module is compatible with the Honeywell 8C-TPOXA1 IOTA?
The 8C-TPOXA1 IOTA is designed to host the Honeywell 8C-IP0102 PROFIBUS Gateway Module within Experion Series 8 control systems, providing network termination and physical connections.
What is the difference between 8C-TPOXA1 and 8U-TPOXA1?
The 8C-TPOXA1 features a conformal coating for corrosion protection in harsh industrial processing environments, whereas the 8U-TPOXA1 is the uncoated version intended for standard cabinet environments.
How do you set the network address on the 8C-TPOXA1 IOTA?
The network node address is set using the three rotary FTE Device Index switches located directly on the face of the IOTA assembly before commissioning or powering up.
Does replacing an 8C-TPOXA1 require system download?
Yes, after replacing the IOTA hardware and reinstalling the gateway module, you must perform a Load with Contents operation using Control Builder to restore proper communication.
Reviews

8C-TPOXA1 51307153-175

Stock & lead time on request

Call
1 su 3

Honeywell 8C-TPOXA1 51307153-175 Experion Series 8 PROFIBUS Gateway IOTA, Coated

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 8C-TPOXA1 51307153-175

  • Country of origin:United States

  • Product Type: IOTA gateway PROFIBUS

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 160 x 310 x 50 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell 8C-TPOXA1 (Part Number 51307153-175) is a conformal coated Input/Output Termination Assembly (IOTA) designed specifically for the Honeywell Experion LX Series 8 Distributed Control System (DCS) platform. It serves as the physical mounting and wiring interface for the Honeywell 8C-IP0102 PROFIBUS Gateway Module (PGM), enabling fieldbus communication links between field instrumentation and the controller system.

This IOTA functions as the vital connection point for external field communication cables, power distribution, and system-level interface routing. Built with factory conformal coating, the 8C-TPOXA1 is engineered to withstand harsh industrial processing environments, preventing board-level contamination and corrosion.

Features

  • Dedicated Gateway Interface: Designed specifically to host the 8C-IP0102 PROFIBUS Gateway Module within the Experion Series 8 architecture.
  • Conformal Coating Protection: Coated circuit board construction provides enhanced resilience against industrial airborne pollutants and moisture.
  • Integrated Connectivity: Features dual FTE-A and FTE-B Ethernet link RJ-45 ports along with PBLink network interface terminals.
  • Addressing Capability: Incorporates three rotary FTE Device Index switches directly on the assembly for hardware node identification.
  • System Bus Isolation: Features grounded mounting interface hardware connecting to the system COM bus bar for proper ground integrity.

Applications

  • Process Control Fieldbus Integration: Hosts PROFIBUS gateway modules connecting smart instrumentation to Experion Series 8 DCS controllers.
  • Corrosive Processing Environments: Ideal for installation in chemical, oil and gas, or manufacturing facilities requiring conformal coated control hardware.
  • Industrial Network Subsystems: Interfacing field devices with high-availability control network topologies.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 8C-TPOXA1
Part Number 51307153-175
Product Type PROFIBUS Gateway IOTA
Series Experion LX Series 8
Coating Conformal Coated
Operating Voltage 24 VDC
Max Current Rating 20 A (Header board subsystem)
Ambient Operating Temperature 0 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Operating Humidity 5% to 95% RH (non-condensing)
Vibration 10–57 Hz (0.075 mm displacement), 57–150 Hz (1 G load)
Mechanical Shock 15 G in 3 axes (11 ms duration)

Connections / Interfaces

Interface / Connector Function
FTE-A (RJ-45) Primary Fault Tolerant Ethernet network link connection
FTE-B (RJ-45) Secondary Fault Tolerant Ethernet network link connection
PBLink Ports PROFIBUS network cable terminal connections
Device Index Switches Three rotary switches for setting FTE hardware network node address
System COM Ground Ground connection interface to cabinet COM bus bar

Installation Guidelines

  1. Verify that the system power supply is isolated or the system is off-process before mounting.
  2. Confirm the IOTA hardware part number and ensure the conformal coating matches installation requirements.
  3. Mount the IOTA onto the cabinet channel rail using the dedicated screws, washers, and spacers.
  4. Tighten the grounding screw on the right side of the IOTA to secure connection to the cabinet COM bus bar.
  5. Ensure the four main mounting screws are tightened uniformly without causing board distortion.
  6. Connect the yellow Cat5 cable to the FTE-A connector and green Cat5 cable to the FTE-B connector.
  7. Terminate PBLink fieldbus cables to their designated connector points.

Configuration and Replacement Recommendations

  • Address Verification: Set the three rotary FTE Device Index switches to match the exact node address of the original unit prior to powering up.
  • Module Seating: When installing the 8C-IP0102 gateway module onto the IOTA, ensure board edge connectors mate cleanly before tightening retention screws.
  • System Load: After hardware replacement, perform a "Load with Contents" operation from Control Builder to update operational parameters.

Compliance and Certifications

  • Low Voltage Directive (LVD): EN 61010-1:2010
  • EMC Directive: EN 61326-1:2006, IEC 61326-1:2005
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 8C-TPOXA1 51307153-175 Experion Series 8 PROFIBUS Gateway IOTA, Coated

What module is compatible with the Honeywell 8C-TPOXA1 IOTA?

The 8C-TPOXA1 IOTA is designed to host the Honeywell 8C-IP0102 PROFIBUS Gateway Module within Experion Series 8 control systems, providing network termination and physical connections.

What is the difference between 8C-TPOXA1 and 8U-TPOXA1?

The 8C-TPOXA1 features a conformal coating for corrosion protection in harsh industrial processing environments, whereas the 8U-TPOXA1 is the uncoated version intended for standard cabinet environments.

How do you set the network address on the 8C-TPOXA1 IOTA?

The network node address is set using the three rotary FTE Device Index switches located directly on the face of the IOTA assembly before commissioning or powering up.

Does replacing an 8C-TPOXA1 require system download?

Yes, after replacing the IOTA hardware and reinstalling the gateway module, you must perform a Load with Contents operation using Control Builder to restore proper communication.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Diagnosi degli alimentatori da 24 V CC senza inseguire guasti fantasma

Un quadro di controllo inattivo non significa automaticamente che l’alimentatore sia guasto. Questa guida sul campo utilizza controlli dell’ingresso, a vuoto, sotto carico, dell’ondulazione, del...

Una catena di segnali pratica per la misurazione e il controllo industriali

Un controllo affidabile inizia prima che il PLC esegua un ciclo. Questa guida di ingegneria segue la catena del segnale dal rilevamento e dal condizionamento fino alla trasmissione, all’azione di...

Modbus sulle reti di impianto: frame, registri e limiti di progettazione

Modbus è ancora ampiamente utilizzato perché il suo modello dati è semplice, non perché ogni implementazione lo sia. Questa guida spiega i frame, la mappatura dei registri, la temporizzazione, la...

All'interno della CPU del PLC: cicli di scansione, memoria e selezione

Una guida pratica di ingegneria al funzionamento della CPU di un PLC, dai cicli di scansione deterministici e dalle tabelle delle immagini degli I/O fino a memoria, comunicazioni, diagnostica,...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.