Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TDI110 Experion Series C Digital Input High Voltage IOTA 120 VAC / 125 VDC

Quantità

Product Description

Description

The Honeywell CC-TDI110 is a non-redundant, 9-inch Input Output Termination Assembly (IOTA) designed for the Experion Process Knowledge System (PKS) Series C architecture. It provides the field termination infrastructure and signal conditioning interface required to connect 120 VAC RMS or 125 VDC discrete field inputs directly to the Honeywell CC-PDIH01 Digital Input High Voltage I/O Module (IOM).

Functioning as a critical hardware interface in process control and monitoring systems, the CC-TDI110 transfers high-voltage field signals into logic-level communications for the supervisory system. The assembly accommodates 32 digital input channels and utilizes optical isolation technology to establish optical galvanic isolation between field circuitry and logic common. This architectural isolation protects sensitive control electronics from field-side voltage transients, ground loops, and electrical noise.

Designed for high availability and operational integrity in industrial processing plants, the Honeywell CC-TDI110 supports extensive internal diagnostic routines executed through the paired CC-PDIH01 module. The hardware assembly features individual channel filtering and configurable direct or reverse input logic to support various field sensor configurations and switch contact monitoring requirements.

Features

  • Serves as a 9-inch non-redundant field termination assembly for 32-channel high-voltage discrete input processing.
  • Directly interfaces with the Honeywell CC-PDIH01 Digital Input High Voltage module within Experion Series C racks.
  • Dual-rating capability accepts both 120 VAC RMS (47–63 Hz) and 125 VDC field signals across a single assembly.
  • Optical galvanic isolation provides 1500 VAC RMS or ±1500 VDC isolation between field wiring and logic common.
  • Executes high-integrity internal diagnostics to verify channel status and maintain signal transmission accuracy.
  • Supports configurable direct and reverse input modes to adapt to diverse field contact behaviors.

Applications

  • Discrete Alarm & Status Monitoring: Captures high-voltage motor contactor status, trip switch signals, and process limit switches.
  • Safety & Interlock Feedback: Interfacing high-voltage field auxiliary contacts with control logic for plant-wide interlocking.
  • Substation & Electrical Balance of Plant: Monitoring 125 VDC control circuit breakers and breaker status contacts in electrical cabinets.
  • Process Equipment Monitoring: Direct signal conditioning for valves, pumps, and fans operating on 120 VAC control loops.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Model Number CC-TDI110
Associated I/O Module CC-PDIH01 (Digital Input High Voltage)
Module Type Input Output Termination Assembly (IOTA)
System Platform Experion PKS Series C
Redundancy Support Non-Redundant
Number of Input Channels 32

Electrical & Signal Ratings

Parameter Specification
Nominal Voltage 120 VAC / 125 VDC
Operating Voltage Range (120 VAC) 90 to 132 VAC RMS
Operating Voltage Range (125 VDC) 100 to 138 VDC
Operating Frequency Range 47 to 63 Hz (AC condition)
Minimum Pick-Up Voltage (ON condition) 90 VAC RMS / 100 VDC
Maximum Drop-Out Voltage (OFF condition) 25 VAC RMS / 25 VDC
Minimum ON Condition Sense Current 1.0 mA (120 VAC) / 1.2 mA (125 VDC)
Maximum OFF Condition Sense Current 0.32 mA (120 VAC) / 0.32 mA (125 VDC)

Performance & Isolation

Parameter Specification
Isolation Voltage (Field to Logic Common) 1500 VAC RMS or ±1500 VDC
Isolation Technique Optical
Delay Across Filter & Isolation (AC) 25 ms maximum
Delay Across Filter & Isolation (DC) 10 ms maximum

Mechanical

Parameter Specification
Assembly Size 9 inches

Installation Guidelines

  1. Inspect the Honeywell CC-TDI110 assembly for physical integrity before mounting.
  2. Ensure power to the target Series C cabinet channel is turned off prior to physical installation.
  3. Securely mount the 9-inch IOTA onto the standard Series C mounting channel using proper mechanical alignment.
  4. Route high-voltage AC/DC field wiring separately from low-voltage DC logic and communication lines to minimize noise coupling.
  5. Connect field input conductors to designated channel screw terminals, observing polarity guidelines when using 125 VDC inputs.
  6. Verify earth grounding connections on the Series C carrier to ensure proper shield grounding and optical isolation performance.
  7. Align and seat the CC-PDIH01 Digital Input High Voltage module firmly onto the IOTA interface connectors until latched.

Configuration & Commissioning

  • Software Assignment: Assign the CC-TDI110 IOTA and corresponding CC-PDIH01 module in Control Builder under the appropriate Series C C300 controller or I/O link tree.
  • Logic Mode Selection: Configure channel logic options (direct or reverse) within Control Builder software to align with field switch contact states (normally open vs. normally closed).
  • Pre-Commissioning Voltage Check: Measure incoming field loop voltages with a multimeter prior to commissioning to ensure AC signals fall within 90–132 VAC RMS or DC signals fall within 100–138 VDC.
  • Channel Diagnostics Verification: Monitor Experion system alarm summaries during startup to confirm proper channel initialization and verify optical isolation logic states without field faults.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell CC-TDI110 IOTA?
The Honeywell CC-TDI110 is a 9-inch non-redundant Input Output Termination Assembly designed to terminate 32 discrete 120 VAC or 125 VDC field input signals and interface them with the CC-PDIH01 Digital Input High Voltage module in Experion Series C systems.
Which I/O module is compatible with the Honeywell CC-TDI110?
The Honeywell CC-TDI110 is specifically engineered to mate with the CC-PDIH01 Digital Input High Voltage I/O Module within Honeywell Experion Process Knowledge System (PKS) architectures.
What are the acceptable input voltage ranges for the Honeywell CC-TDI110?
The Honeywell CC-TDI110 accepts 120 VAC RMS signals within a range of 90 to 132 VAC RMS (47–63 Hz) and 125 VDC signals within a range of 100 to 138 VDC.
Does the Honeywell CC-TDI110 offer galvanic isolation for field signals?
Yes, the Honeywell CC-TDI110 provides optical galvanic isolation up to 1500 VAC RMS or ±1500 VDC between field circuitry and logic common to protect internal system electronics.
Reviews

CC-TDI110

Stock & lead time on request

Call
1 su 3

Honeywell CC-TDI110 Experion Series C Digital Input High Voltage IOTA 120 VAC / 125 VDC

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-TDI110

  • Country of origin:United States

  • Product Type: Digital Input Termination Assemblies

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 228 x 125 x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell CC-TDI110 is a non-redundant, 9-inch Input Output Termination Assembly (IOTA) designed for the Experion Process Knowledge System (PKS) Series C architecture. It provides the field termination infrastructure and signal conditioning interface required to connect 120 VAC RMS or 125 VDC discrete field inputs directly to the Honeywell CC-PDIH01 Digital Input High Voltage I/O Module (IOM).

Functioning as a critical hardware interface in process control and monitoring systems, the CC-TDI110 transfers high-voltage field signals into logic-level communications for the supervisory system. The assembly accommodates 32 digital input channels and utilizes optical isolation technology to establish optical galvanic isolation between field circuitry and logic common. This architectural isolation protects sensitive control electronics from field-side voltage transients, ground loops, and electrical noise.

Designed for high availability and operational integrity in industrial processing plants, the Honeywell CC-TDI110 supports extensive internal diagnostic routines executed through the paired CC-PDIH01 module. The hardware assembly features individual channel filtering and configurable direct or reverse input logic to support various field sensor configurations and switch contact monitoring requirements.

Features

  • Serves as a 9-inch non-redundant field termination assembly for 32-channel high-voltage discrete input processing.
  • Directly interfaces with the Honeywell CC-PDIH01 Digital Input High Voltage module within Experion Series C racks.
  • Dual-rating capability accepts both 120 VAC RMS (47–63 Hz) and 125 VDC field signals across a single assembly.
  • Optical galvanic isolation provides 1500 VAC RMS or ±1500 VDC isolation between field wiring and logic common.
  • Executes high-integrity internal diagnostics to verify channel status and maintain signal transmission accuracy.
  • Supports configurable direct and reverse input modes to adapt to diverse field contact behaviors.

Applications

  • Discrete Alarm & Status Monitoring: Captures high-voltage motor contactor status, trip switch signals, and process limit switches.
  • Safety & Interlock Feedback: Interfacing high-voltage field auxiliary contacts with control logic for plant-wide interlocking.
  • Substation & Electrical Balance of Plant: Monitoring 125 VDC control circuit breakers and breaker status contacts in electrical cabinets.
  • Process Equipment Monitoring: Direct signal conditioning for valves, pumps, and fans operating on 120 VAC control loops.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Model Number CC-TDI110
Associated I/O Module CC-PDIH01 (Digital Input High Voltage)
Module Type Input Output Termination Assembly (IOTA)
System Platform Experion PKS Series C
Redundancy Support Non-Redundant
Number of Input Channels 32

Electrical & Signal Ratings

Parameter Specification
Nominal Voltage 120 VAC / 125 VDC
Operating Voltage Range (120 VAC) 90 to 132 VAC RMS
Operating Voltage Range (125 VDC) 100 to 138 VDC
Operating Frequency Range 47 to 63 Hz (AC condition)
Minimum Pick-Up Voltage (ON condition) 90 VAC RMS / 100 VDC
Maximum Drop-Out Voltage (OFF condition) 25 VAC RMS / 25 VDC
Minimum ON Condition Sense Current 1.0 mA (120 VAC) / 1.2 mA (125 VDC)
Maximum OFF Condition Sense Current 0.32 mA (120 VAC) / 0.32 mA (125 VDC)

Performance & Isolation

Parameter Specification
Isolation Voltage (Field to Logic Common) 1500 VAC RMS or ±1500 VDC
Isolation Technique Optical
Delay Across Filter & Isolation (AC) 25 ms maximum
Delay Across Filter & Isolation (DC) 10 ms maximum

Mechanical

Parameter Specification
Assembly Size 9 inches

Installation Guidelines

  1. Inspect the Honeywell CC-TDI110 assembly for physical integrity before mounting.
  2. Ensure power to the target Series C cabinet channel is turned off prior to physical installation.
  3. Securely mount the 9-inch IOTA onto the standard Series C mounting channel using proper mechanical alignment.
  4. Route high-voltage AC/DC field wiring separately from low-voltage DC logic and communication lines to minimize noise coupling.
  5. Connect field input conductors to designated channel screw terminals, observing polarity guidelines when using 125 VDC inputs.
  6. Verify earth grounding connections on the Series C carrier to ensure proper shield grounding and optical isolation performance.
  7. Align and seat the CC-PDIH01 Digital Input High Voltage module firmly onto the IOTA interface connectors until latched.

Configuration & Commissioning

  • Software Assignment: Assign the CC-TDI110 IOTA and corresponding CC-PDIH01 module in Control Builder under the appropriate Series C C300 controller or I/O link tree.
  • Logic Mode Selection: Configure channel logic options (direct or reverse) within Control Builder software to align with field switch contact states (normally open vs. normally closed).
  • Pre-Commissioning Voltage Check: Measure incoming field loop voltages with a multimeter prior to commissioning to ensure AC signals fall within 90–132 VAC RMS or DC signals fall within 100–138 VDC.
  • Channel Diagnostics Verification: Monitor Experion system alarm summaries during startup to confirm proper channel initialization and verify optical isolation logic states without field faults.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TDI110 Experion Series C Digital Input High Voltage IOTA 120 VAC / 125 VDC

What is the primary function of the Honeywell CC-TDI110 IOTA?

The Honeywell CC-TDI110 is a 9-inch non-redundant Input Output Termination Assembly designed to terminate 32 discrete 120 VAC or 125 VDC field input signals and interface them with the CC-PDIH01 Digital Input High Voltage module in Experion Series C systems.

Which I/O module is compatible with the Honeywell CC-TDI110?

The Honeywell CC-TDI110 is specifically engineered to mate with the CC-PDIH01 Digital Input High Voltage I/O Module within Honeywell Experion Process Knowledge System (PKS) architectures.

What are the acceptable input voltage ranges for the Honeywell CC-TDI110?

The Honeywell CC-TDI110 accepts 120 VAC RMS signals within a range of 90 to 132 VAC RMS (47–63 Hz) and 125 VDC signals within a range of 100 to 138 VDC.

Does the Honeywell CC-TDI110 offer galvanic isolation for field signals?

Yes, the Honeywell CC-TDI110 provides optical galvanic isolation up to 1500 VAC RMS or ±1500 VDC between field circuitry and logic common to protect internal system electronics.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered DC Power

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.