Honeywell

Honeywell FC-SCNT02 51460114-17 Safety Manager SC Controller Module

SKU FC-SCNT02 51460114-176

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: FC-SCNT02 51460114-176
  • Origin United States
  • Product Type: Controller Module
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.65 kg
  • Dimensions: 140 mm x 220 mm x 45 mm (D x H x W)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-SCNT02 51460114-17 Safety Manager SC Controller Module

Quantità

Product Description

Description

The Honeywell FC-SCNT02 is a controller module engineered for the Safety Manager SC system. It serves as a functional replacement for the FC-SCNT01 module within safety system architectures and can be swapped online without interrupting process operations. In redundant Safety Manager SC (SMSC) controller configurations, the module functions side-by-side with an existing FC-SCNT01 module.

The module supports DNP3 protocol outstation functionality starting with Safety Manager SC release R212, allowing the Safety Manager SC to operate as a DNP3 Outstation while communicating with a DNP3 Master such as an Experion Server or ControlEdge RTU. It also functions as a direct spare part for the FC-SCNT01 module, maintaining full operational feature parity with the legacy module.

Features

  • Direct functional replacement and spare part for the FC-SCNT01 controller module
  • Online replacement capability without disrupting running operations
  • Redundant operations support, functioning alongside an FC-SCNT01 module in SMSC controllers
  • Integrated DNP3 protocol outstation support (requires release R212)
  • Compatible with Safety Manager SC software release R200.2 and higher

Applications

  • Safety Instrumented Systems (SIS) and Emergency Shutdown (ESD) applications
  • Safety Manager SC redundant controller configurations
  • Industrial SCADA telecontrol communication networks utilizing DNP3 protocol outstation integration

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model FC-SCNT02
Part Mumber 51460114-17
System Compatibility Safety Manager SC
Supported Software Release Safety Manager SC R200.2 and higher
DNP3 Protocol Support Release Safety Manager SC R212 and higher
Module Replacement Mode Online replacement / Hot Swap capable
Redundancy Support Dual redundant controller configuration with FC-SCNT01

Installation Guidelines

  • Online Replacement: The module can be installed or replaced online in a running Safety Manager SC system without requiring a shutdown.
  • Redundant Pair Coexistence: In redundant controller setups, an FC-SCNT02 module can be installed alongside an existing FC-SCNT01 module.
  • Software Prerequisites: Verify that the Safety Manager SC system software is at release R200.2 or higher before module installation, and release R212 or higher if utilizing DNP3 outstation features.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Can this controller module replace an older FC-SCNT01 module?
Yes, the module is a direct functional replacement and spare part for the FC-SCNT01 module and can operate online within the system.
Can the module operate alongside an existing FC-SCNT01 in a redundant system?
Yes, it can function with another FC-SCNT01 module in a redundant Safety Manager SC controller configuration.
Which software release is required to support this controller module?
The module is supported on Safety Manager SC release R200.2 and higher.
Which software release is required for DNP3 protocol outstation support?
DNP3 protocol outstation functionality is supported starting with Safety Manager SC release R212.
Reviews

FC-SCNT02 51460114-176

Stock & lead time on request

Call
1 su 2

Honeywell FC-SCNT02 51460114-17 Safety Manager SC Controller Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FC-SCNT02 51460114-176

  • Country of origin:United States

  • Product Type: Controller Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 140 mm x 220 mm x 45 mm (D x H x W)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell FC-SCNT02 is a controller module engineered for the Safety Manager SC system. It serves as a functional replacement for the FC-SCNT01 module within safety system architectures and can be swapped online without interrupting process operations. In redundant Safety Manager SC (SMSC) controller configurations, the module functions side-by-side with an existing FC-SCNT01 module.

The module supports DNP3 protocol outstation functionality starting with Safety Manager SC release R212, allowing the Safety Manager SC to operate as a DNP3 Outstation while communicating with a DNP3 Master such as an Experion Server or ControlEdge RTU. It also functions as a direct spare part for the FC-SCNT01 module, maintaining full operational feature parity with the legacy module.

Features

  • Direct functional replacement and spare part for the FC-SCNT01 controller module
  • Online replacement capability without disrupting running operations
  • Redundant operations support, functioning alongside an FC-SCNT01 module in SMSC controllers
  • Integrated DNP3 protocol outstation support (requires release R212)
  • Compatible with Safety Manager SC software release R200.2 and higher

Applications

  • Safety Instrumented Systems (SIS) and Emergency Shutdown (ESD) applications
  • Safety Manager SC redundant controller configurations
  • Industrial SCADA telecontrol communication networks utilizing DNP3 protocol outstation integration

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model FC-SCNT02
Part Mumber 51460114-17
System Compatibility Safety Manager SC
Supported Software Release Safety Manager SC R200.2 and higher
DNP3 Protocol Support Release Safety Manager SC R212 and higher
Module Replacement Mode Online replacement / Hot Swap capable
Redundancy Support Dual redundant controller configuration with FC-SCNT01

Installation Guidelines

  • Online Replacement: The module can be installed or replaced online in a running Safety Manager SC system without requiring a shutdown.
  • Redundant Pair Coexistence: In redundant controller setups, an FC-SCNT02 module can be installed alongside an existing FC-SCNT01 module.
  • Software Prerequisites: Verify that the Safety Manager SC system software is at release R200.2 or higher before module installation, and release R212 or higher if utilizing DNP3 outstation features.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-SCNT02 51460114-17 Safety Manager SC Controller Module

Can this controller module replace an older FC-SCNT01 module?

Yes, the module is a direct functional replacement and spare part for the FC-SCNT01 module and can operate online within the system.

Can the module operate alongside an existing FC-SCNT01 in a redundant system?

Yes, it can function with another FC-SCNT01 module in a redundant Safety Manager SC controller configuration.

Which software release is required to support this controller module?

The module is supported on Safety Manager SC release R200.2 and higher.

Which software release is required for DNP3 protocol outstation support?

DNP3 protocol outstation functionality is supported starting with Safety Manager SC release R212.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500