Honeywell

Honeywell MU-KFTA05 TH51201420-005 FTA I/O Cable

SKU MU-KFTA05 TH51201420-005

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: MU-KFTA05 TH51201420-005
  • Origin United States
  • Product Type: FTA I/O Cables
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.3 kg
  • Dimensions: 7cm x 14cm x 14.5cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The Honeywell MU-KFTA05 (TH51201420-005) is a specialized Field Termination Assembly (FTA) I/O cable designed to establish reliable signal paths between FTAs and Input/Output Processors (IOPs). Developed for use within Honeywell industrial automation architectures, this purpose-built interconnect cable provides dependable communication links required for continuous process monitoring and control operations.

This cable facilitates organized signal distribution, helping to minimize wiring complexity within control cabinets. It acts as a dedicated physical link within legacy and ongoing TDC 3000 and related distributed control system deployments, supporting maintainable and structured cabinet layouts.

Features

  • Engineered specifically for Honeywell TDC 3000 and compatible control system architectures
  • Provides secure connection between Field Termination Assemblies (FTAs) and I/O Processors (IOPs)
  • Standard 5-meter length accommodates flexible internal cabinet routing and layout planning
  • Constructed for dependable signal integrity in demanding industrial process environments

Applications

  • Distributed Control System (DCS) cabinet signal wiring
  • Process automation and continuous manufacturing facilities
  • Refining, chemical, and petrochemical plant control systems
  • Power generation and utility infrastructure monitoring

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model / Part Number MU-KFTA05
Alternative ID TH51201420-005
Product Type FTA I/O Cable
System Compatibility Honeywell TDC 3000 / UCN environments
Cable Length 5 meters
Connector Type Male-to-male configuration
Operating Temperature Range -40 Celsius to +85 Celsius
Net Weight 0.3 kg
Country of Origin United States

Installation Guidelines

  1. Verify the part number MU-KFTA05 (TH51201420-005) against system documentation prior to installation.
  2. Ensure all associated cabinet power and I/O power supplies are de-energized before handling cables.
  3. Inspect the cable connectors and pins for any signs of transit damage or contamination.
  4. Route the 5-meter cable through designated wire trays, maintaining adequate separation from high-voltage power cabling to prevent electromagnetic interference.
  5. Securely mate the connectors to the appropriate FTA and IOP ports, fastening retention screws or latches where provided.
  6. Verify system communication and signal loop integrity through the control system diagnostic interface during commissioning.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell MU-KFTA05 cable?
The Honeywell MU-KFTA05 (TH51201420-005) is a dedicated FTA I/O cable used to connect Field Termination Assemblies to Input/Output Processors within Honeywell control architectures.
Which control systems are compatible with the MU-KFTA05 cable?
The Honeywell MU-KFTA05 cable is specifically engineered for compatibility with Honeywell TDC 3000 and related distributed control system environments.
What is the length of the Honeywell MU-KFTA05 cable?
The Honeywell MU-KFTA05 FTA I/O cable has a standard length of 5 meters, providing flexible routing options within control cabinets.
What is the operating temperature range for this cable?
The Honeywell MU-KFTA05 cable is rated to operate reliably in industrial environments ranging from -40 Celsius to +85 Celsius.
Reviews

MU-KFTA05 TH51201420-005

Stock & lead time on request

Call
1 su 3

Honeywell MU-KFTA05 TH51201420-005 FTA I/O Cable

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: MU-KFTA05 TH51201420-005

  • Country of origin:United States

  • Product Type: FTA I/O Cables

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 7cm x 14cm x 14.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell MU-KFTA05 (TH51201420-005) is a specialized Field Termination Assembly (FTA) I/O cable designed to establish reliable signal paths between FTAs and Input/Output Processors (IOPs). Developed for use within Honeywell industrial automation architectures, this purpose-built interconnect cable provides dependable communication links required for continuous process monitoring and control operations.

This cable facilitates organized signal distribution, helping to minimize wiring complexity within control cabinets. It acts as a dedicated physical link within legacy and ongoing TDC 3000 and related distributed control system deployments, supporting maintainable and structured cabinet layouts.

Features

  • Engineered specifically for Honeywell TDC 3000 and compatible control system architectures
  • Provides secure connection between Field Termination Assemblies (FTAs) and I/O Processors (IOPs)
  • Standard 5-meter length accommodates flexible internal cabinet routing and layout planning
  • Constructed for dependable signal integrity in demanding industrial process environments

Applications

  • Distributed Control System (DCS) cabinet signal wiring
  • Process automation and continuous manufacturing facilities
  • Refining, chemical, and petrochemical plant control systems
  • Power generation and utility infrastructure monitoring

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model / Part Number MU-KFTA05
Alternative ID TH51201420-005
Product Type FTA I/O Cable
System Compatibility Honeywell TDC 3000 / UCN environments
Cable Length 5 meters
Connector Type Male-to-male configuration
Operating Temperature Range -40 Celsius to +85 Celsius
Net Weight 0.3 kg
Country of Origin United States

Installation Guidelines

  1. Verify the part number MU-KFTA05 (TH51201420-005) against system documentation prior to installation.
  2. Ensure all associated cabinet power and I/O power supplies are de-energized before handling cables.
  3. Inspect the cable connectors and pins for any signs of transit damage or contamination.
  4. Route the 5-meter cable through designated wire trays, maintaining adequate separation from high-voltage power cabling to prevent electromagnetic interference.
  5. Securely mate the connectors to the appropriate FTA and IOP ports, fastening retention screws or latches where provided.
  6. Verify system communication and signal loop integrity through the control system diagnostic interface during commissioning.
Loading product navigation…
Key Features:

What is the primary function of the Honeywell MU-KFTA05 cable?

The Honeywell MU-KFTA05 (TH51201420-005) is a dedicated FTA I/O cable used to connect Field Termination Assemblies to Input/Output Processors within Honeywell control architectures.

Which control systems are compatible with the MU-KFTA05 cable?

The Honeywell MU-KFTA05 cable is specifically engineered for compatibility with Honeywell TDC 3000 and related distributed control system environments.

What is the length of the Honeywell MU-KFTA05 cable?

The Honeywell MU-KFTA05 FTA I/O cable has a standard length of 5 meters, providing flexible routing options within control cabinets.

What is the operating temperature range for this cable?

The Honeywell MU-KFTA05 cable is rated to operate reliably in industrial environments ranging from -40 Celsius to +85 Celsius.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.