Honeywell

Honeywell MU-TAMT02 51401491-100 High Process Manager LLMux TC FTA

SKU MU-TAMT02 51401491-100

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: MU-TAMT02 51401491-100
  • Origin United States
  • Product Type: Field Termination Assemblies
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell MU-TAMT02 51401491-100 High Process Manager LLMux TC FTA

Quantità

Product Description

Description

The Honeywell MU-TAMT02 51401491-100 is a Low Level Analog Input Multiplexer Thermocouple (LLMux TC) Field Termination Assembly (FTA) designed for use within the Honeywell High Process Manager (HPM) subsystem. The MU-TAMT02 serves as the physical field interface for low-level analog input signals coming from thermocouples, routing these field signals directly to the Process Manager I/O Processors (IOP) via dedicated FTA cabling. Featuring a non-conformally coated assembly construction, the 51401491-100 FTA provides reliable termination, signal routing, and interface integrity for temperature monitoring in industrial automation and DCS control applications.

Features

  • Designed for Low Level Analog Input Multiplexer Thermocouple (LLMux TC) signal processing
  • Non-conformally coated printed circuit board assembly
  • Direct field wiring interface for thermocouple temperature sensors
  • Serves as standard Non-CE Compliant Field Termination Assembly (FTA)

Applications

  • Distributed Control Systems (DCS) process control
  • Thermocouple temperature input signal termination and multiplexing
  • Industrial process automation and monitoring in High Process Manager (HPM) systems

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number MU-TAMT02
Part Number 51401491-100
Module Type LLMux TC FTA (Low Level Multiplexer Thermocouple Field Termination Assembly)
System Compatibility High Process Manager (HPM)
Coating Non-conformally Coated
Standard Compliance Non-CE Compliant

Installation Guidelines

  • Ensure system power is disconnected before installing or removing the Field Termination Assembly.
  • Route field wiring and thermocouple signal cables separately from high-voltage AC cables to minimize electromagnetic interference.
  • Maintain proper shield grounding practices at designated ground terminals on the assembly to preserve signal accuracy.
  • Ensure adequate enclosure cabinet ventilation to maintain operating temperature limits.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What type of signals does the module support?
The module is designed specifically for terminating and multiplexing low-level analog input signals from thermocouples.
Is the device conformally coated?
No, part number 51401491-100 is a non-conformally coated assembly.
Which control system uses this Field Termination Assembly?
The assembly is designed for use within the Honeywell High Process Manager system.
Reviews

MU-TAMT02 51401491-100

Stock & lead time on request

Call
1 su 3

Honeywell MU-TAMT02 51401491-100 High Process Manager LLMux TC FTA

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: MU-TAMT02 51401491-100

  • Country of origin:United States

  • Product Type: Field Termination Assemblies

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell MU-TAMT02 51401491-100 is a Low Level Analog Input Multiplexer Thermocouple (LLMux TC) Field Termination Assembly (FTA) designed for use within the Honeywell High Process Manager (HPM) subsystem. The MU-TAMT02 serves as the physical field interface for low-level analog input signals coming from thermocouples, routing these field signals directly to the Process Manager I/O Processors (IOP) via dedicated FTA cabling. Featuring a non-conformally coated assembly construction, the 51401491-100 FTA provides reliable termination, signal routing, and interface integrity for temperature monitoring in industrial automation and DCS control applications.

Features

  • Designed for Low Level Analog Input Multiplexer Thermocouple (LLMux TC) signal processing
  • Non-conformally coated printed circuit board assembly
  • Direct field wiring interface for thermocouple temperature sensors
  • Serves as standard Non-CE Compliant Field Termination Assembly (FTA)

Applications

  • Distributed Control Systems (DCS) process control
  • Thermocouple temperature input signal termination and multiplexing
  • Industrial process automation and monitoring in High Process Manager (HPM) systems

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number MU-TAMT02
Part Number 51401491-100
Module Type LLMux TC FTA (Low Level Multiplexer Thermocouple Field Termination Assembly)
System Compatibility High Process Manager (HPM)
Coating Non-conformally Coated
Standard Compliance Non-CE Compliant

Installation Guidelines

  • Ensure system power is disconnected before installing or removing the Field Termination Assembly.
  • Route field wiring and thermocouple signal cables separately from high-voltage AC cables to minimize electromagnetic interference.
  • Maintain proper shield grounding practices at designated ground terminals on the assembly to preserve signal accuracy.
  • Ensure adequate enclosure cabinet ventilation to maintain operating temperature limits.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell MU-TAMT02 51401491-100 High Process Manager LLMux TC FTA

What type of signals does the module support?

The module is designed specifically for terminating and multiplexing low-level analog input signals from thermocouples.

Is the device conformally coated?

No, part number 51401491-100 is a non-conformally coated assembly.

Which control system uses this Field Termination Assembly?

The assembly is designed for use within the Honeywell High Process Manager system.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.