Honeywell

Honeywell S4560C1053U S4560 Series Ignition Control Module

SKU S4560C1053U

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: S4560C1053U
  • Origin United States
  • Product Type: Ignition Control Modules
  • Payment: T/T, Western Union
  • Weight: 1.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Designed to provide reliable automatic safety regulation and flame supervision for burner systems, the Honeywell S4560C1053U serves as a robust ignition control module. This controller is engineered to comply with the stringent safety requirements of the EN 298 standard, managing safe ignition sequence, burner operation, and flame detection in heating applications. Primarily integrated into residential, domestic, and small commercial boiler systems, it supports both atmospheric and fan-assisted burner arrangements to guarantee secure operational cycles.

Features

  • Ensures fully automatic burner control and flame supervision.
  • Complies with European safety standard EN 298.
  • Optimized for domestic heating and small commercial boiler systems.
  • Incorporates secure start-up safety checks and immediate lockout on flame failure.
  • Durable housing structure built to withstand industrial thermal and mechanical stresses.

Applications

  • Domestic gas-fired heating boilers.
  • Small commercial boiler installations.
  • Atmospheric gas burners.
  • Fan-assisted heating appliances.

Technical Specifications

Manufacturer Honeywell
Part Number / Model S4560C1053U
Series S4560
Device Type Ignition Control Module
Applicable Standards EN 298
Burner Compatibility Atmospheric or Fan-Assisted Burners
Application Scope Domestic and Small Commercial Boilers
Shipping Weight 1.5 kg

Installation Guidelines

Installation must be executed by qualified personnel in compliance with local regulatory electrical and gas safety codes. Prior to mounting or wiring, ensure the main power supply and gas lines are completely shut off. The ignition control module must be mounted in an environment free of moisture, excessive vibration, and high electromagnetic interference. Proper grounding of both the controller and burner frame is critical to maintain correct flame ionization signal strength and prevent false lockouts.

Compliance and Certifications

  • CE Certified
  • EN 298 Compliant
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell S4560C1053U?
The Honeywell S4560C1053U is designed for automatic ignition sequence control and flame monitoring in domestic or small commercial gas-fired boilers.
Which safety standard does this controller comply with?
This module is fully compliant with the EN 298 European standard for automatic gas burner control systems.
Can the S4560C1053U be used with fan-assisted burners?
Yes, it is designed for use in both atmospheric and fan-assisted burner architectures.
Reviews

S4560C1053U

Stock & lead time on request

Call
1 su 1

Honeywell S4560C1053U S4560 Series Ignition Control Module

Only 7 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: S4560C1053U

  • Country of origin:United States

  • Product Type: Ignition Control Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Designed to provide reliable automatic safety regulation and flame supervision for burner systems, the Honeywell S4560C1053U serves as a robust ignition control module. This controller is engineered to comply with the stringent safety requirements of the EN 298 standard, managing safe ignition sequence, burner operation, and flame detection in heating applications. Primarily integrated into residential, domestic, and small commercial boiler systems, it supports both atmospheric and fan-assisted burner arrangements to guarantee secure operational cycles.

Features

  • Ensures fully automatic burner control and flame supervision.
  • Complies with European safety standard EN 298.
  • Optimized for domestic heating and small commercial boiler systems.
  • Incorporates secure start-up safety checks and immediate lockout on flame failure.
  • Durable housing structure built to withstand industrial thermal and mechanical stresses.

Applications

  • Domestic gas-fired heating boilers.
  • Small commercial boiler installations.
  • Atmospheric gas burners.
  • Fan-assisted heating appliances.

Technical Specifications

Manufacturer Honeywell
Part Number / Model S4560C1053U
Series S4560
Device Type Ignition Control Module
Applicable Standards EN 298
Burner Compatibility Atmospheric or Fan-Assisted Burners
Application Scope Domestic and Small Commercial Boilers
Shipping Weight 1.5 kg

Installation Guidelines

Installation must be executed by qualified personnel in compliance with local regulatory electrical and gas safety codes. Prior to mounting or wiring, ensure the main power supply and gas lines are completely shut off. The ignition control module must be mounted in an environment free of moisture, excessive vibration, and high electromagnetic interference. Proper grounding of both the controller and burner frame is critical to maintain correct flame ionization signal strength and prevent false lockouts.

Compliance and Certifications

  • CE Certified
  • EN 298 Compliant

What is the primary function of the Honeywell S4560C1053U?

The Honeywell S4560C1053U is designed for automatic ignition sequence control and flame monitoring in domestic or small commercial gas-fired boilers.

Which safety standard does this controller comply with?

This module is fully compliant with the EN 298 European standard for automatic gas burner control systems.

Can the S4560C1053U be used with fan-assisted burners?

Yes, it is designed for use in both atmospheric and fan-assisted burner architectures.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.