Omron

Omron 3G3MX2-A4015-ZV1 MX2 Series Multi-Function Compact Inverter

SKU 3G3MX2-A4015-ZV1

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron
  • Product No.: 3G3MX2-A4015-ZV1
  • Origin Japan
  • Product Type: Variable Frequency Drives
  • Payment: T/T, Western Union
  • Weight: 4.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Engineered for highly dynamic machine control and precise speed regulation, the Omron 3G3MX2-A4015-ZV1 serves as a high-torque multi-function compact inverter from the renowned MX2 Series. Designed to integrate directly into complex automation systems, this variable frequency drive utilizes advanced sensorless vector control algorithms to achieve up to 200 percent starting torque at 0.5 Hz, making it exceptionally reliable for high-inertia start-up loads. Equipped with a dual rating system, it allows operators to configure the drive for either heavy-duty Constant Torque (CT) or normal-duty Variable Torque (VT) operations, optimizing cost and physical footprint within control enclosures.

Key Features

  • High Starting Torque: Delivers 200 percent starting torque at 0.5 Hz under sensorless vector control mode, ensuring smooth control of demanding loads.
  • Dual Performance Rating: Supports dual rating applications (CT: 1.5 kW / VT: 2.2 kW) for flexible machinery sizing.
  • Integrated Safety: Features built-in dual-channel Safe Torque Off (STO) functionality complying with ISO 13849-1 Cat 3 PLd standards, eliminating the need for external safety contactors.
  • Embedded Logic: Built-in Drive Programming tool allows standard PLC-like logical control programs to run directly within the drive.
  • Communications Capability: Standard RS-485 Modbus RTU interface with expansion options for EtherCAT, DeviceNet, Profibus, and EtherNet/IP.

Applications

  • High-speed industrial conveyors and sorting systems requiring rapid acceleration and deceleration.
  • Packaging machinery with synchronized axis control and demanding duty cycles.
  • Industrial mixers, agitators, and extruders requiring heavy-duty torque characteristics.
  • Variable speed fan and pump configurations utilizing energy-saving modes.

Technical Specifications

Parameter Value
Manufacturer Omron
Model Code 3G3MX2-A4015-ZV1
Product Series MX2 Series V2.1 / ZV1 Revision
Input Voltage Class 3-phase 380 to 480 VAC (+10% / -15%), 50/60 Hz (+/-5%)
Motor Capacity (Heavy Duty - CT) 1.5 kW
Motor Capacity (Normal Duty - VT) 2.2 kW
Rated Output Current (CT) 4.1 A
Rated Output Current (VT) 4.8 A
Enclosure Protection Rating IP20 (Panel Mounting Type)
Control Method Phase-to-phase sinusoidal PWM (V/f control, Sensorless Vector)
Ambient Operating Temperature -10 to +50 degC (Without derating)
Net Physical Weight 1.8 kg
Shipping Weight (Calculated) 4.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility: The "-ZV1" suffix indicates an updated, firmware-enhanced model that complies fully with modernized European and North American safety profiles and improves parameter replication. It is fully backwards-compatible with older, legacy non-ZV1 3G3MX2-A4015 systems, allowing for drop-in physical and logical replacement in established control panels.

Application Pitfalls & Engineering Notes: When operating the drive in a sealed enclosure under high-ambient plant environments (approaching 50 degC), derating calculations must be carefully evaluated. Maintain a minimum of 100 mm top and bottom clearance to avoid local thermal traps. For continuous heavy cyclical start-stop profiles, external dynamic braking resistors are highly recommended to prevent overvoltage trips (DC bus overvoltage errors) during sudden deceleration phases.

Commissioning & Wiring Tips: To meet EMC directive requirements, motor cables must be fully shielded, with the shielding grounded securely at both the motor housing and the drive panel chassis. When routing analog control signals (e.g., 4-20 mA or 0-10 V for speed reference), ensure cables are run in a separate conduit from high-voltage input and output power feeds to prevent electromagnetic noise coupling.

Installation Guidelines

CRITICAL WARNING:

Ensure all main power sources (L1, L2, L3) are locked out and tagged out prior to making physical connections. Wait a minimum of 10 minutes after disconnecting power for internal capacitors to fully discharge. Always verify that the DC bus voltage across terminals P/+ and N/- has dropped below 50 VDC using a certified multimeter before handling drive wiring.

1

Mount the inverter vertically to a rigid, flat metal backplate using the integrated mounting brackets to maximize heat dissipation.

2

Connect incoming 3-phase power line wiring to terminals L1, L2, and L3. Connect the three motor power leads to terminals U, V, and W.

3

Establish protective ground connections at the ground terminal. Ensure connection resistance is under 10 ohms (Class D grounding).

4

Apply power and use the digital operator panel or CX-Drive software to set critical motor parameters, including rated current, base frequency, and control selection mode.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the differences between the ZV1 variant and older 3G3MX2 models?
The -ZV1 model features updated firmware that supports advanced functional safety standards and enhanced parameter transfer options, while remaining fully backwards-compatible for legacy 3G3MX2-A4015 applications.
Does this drive support single-phase input voltage?
No. The 3G3MX2-A4015-ZV1 is designed strictly for three-phase 380 to 480 VAC supply. Operating it on a single-phase supply can cause phase loss protection faults and thermal overloading.
How do I clear an overcurrent fault (E01 to E04) on startup?
Check the acceleration time parameter (F002) and lengthen it. Additionally, verify motor insulation, ensure the motor capacity matches the drive's CT setting, and confirm the motor shaft is free to spin without mechanical blockages.
Is an external contactor required to meet functional safety standards?
No. The integrated dual-channel Safe Torque Off (STO) function complies with ISO 13849-1 PLd, meaning safe power interruption to the motor can be managed directly by the drive's safety inputs without external mains contactors.
Reviews

3G3MX2-A4015-ZV1

Stock & lead time on request

Call
1 su 1

Omron 3G3MX2-A4015-ZV1 MX2 Series Multi-Function Compact Inverter

Only 7 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: 3G3MX2-A4015-ZV1

  • Country of origin:Japan

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 4000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Engineered for highly dynamic machine control and precise speed regulation, the Omron 3G3MX2-A4015-ZV1 serves as a high-torque multi-function compact inverter from the renowned MX2 Series. Designed to integrate directly into complex automation systems, this variable frequency drive utilizes advanced sensorless vector control algorithms to achieve up to 200 percent starting torque at 0.5 Hz, making it exceptionally reliable for high-inertia start-up loads. Equipped with a dual rating system, it allows operators to configure the drive for either heavy-duty Constant Torque (CT) or normal-duty Variable Torque (VT) operations, optimizing cost and physical footprint within control enclosures.

Key Features

  • High Starting Torque: Delivers 200 percent starting torque at 0.5 Hz under sensorless vector control mode, ensuring smooth control of demanding loads.
  • Dual Performance Rating: Supports dual rating applications (CT: 1.5 kW / VT: 2.2 kW) for flexible machinery sizing.
  • Integrated Safety: Features built-in dual-channel Safe Torque Off (STO) functionality complying with ISO 13849-1 Cat 3 PLd standards, eliminating the need for external safety contactors.
  • Embedded Logic: Built-in Drive Programming tool allows standard PLC-like logical control programs to run directly within the drive.
  • Communications Capability: Standard RS-485 Modbus RTU interface with expansion options for EtherCAT, DeviceNet, Profibus, and EtherNet/IP.

Applications

  • High-speed industrial conveyors and sorting systems requiring rapid acceleration and deceleration.
  • Packaging machinery with synchronized axis control and demanding duty cycles.
  • Industrial mixers, agitators, and extruders requiring heavy-duty torque characteristics.
  • Variable speed fan and pump configurations utilizing energy-saving modes.

Technical Specifications

Parameter Value
Manufacturer Omron
Model Code 3G3MX2-A4015-ZV1
Product Series MX2 Series V2.1 / ZV1 Revision
Input Voltage Class 3-phase 380 to 480 VAC (+10% / -15%), 50/60 Hz (+/-5%)
Motor Capacity (Heavy Duty - CT) 1.5 kW
Motor Capacity (Normal Duty - VT) 2.2 kW
Rated Output Current (CT) 4.1 A
Rated Output Current (VT) 4.8 A
Enclosure Protection Rating IP20 (Panel Mounting Type)
Control Method Phase-to-phase sinusoidal PWM (V/f control, Sensorless Vector)
Ambient Operating Temperature -10 to +50 degC (Without derating)
Net Physical Weight 1.8 kg
Shipping Weight (Calculated) 4.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility: The "-ZV1" suffix indicates an updated, firmware-enhanced model that complies fully with modernized European and North American safety profiles and improves parameter replication. It is fully backwards-compatible with older, legacy non-ZV1 3G3MX2-A4015 systems, allowing for drop-in physical and logical replacement in established control panels.

Application Pitfalls & Engineering Notes: When operating the drive in a sealed enclosure under high-ambient plant environments (approaching 50 degC), derating calculations must be carefully evaluated. Maintain a minimum of 100 mm top and bottom clearance to avoid local thermal traps. For continuous heavy cyclical start-stop profiles, external dynamic braking resistors are highly recommended to prevent overvoltage trips (DC bus overvoltage errors) during sudden deceleration phases.

Commissioning & Wiring Tips: To meet EMC directive requirements, motor cables must be fully shielded, with the shielding grounded securely at both the motor housing and the drive panel chassis. When routing analog control signals (e.g., 4-20 mA or 0-10 V for speed reference), ensure cables are run in a separate conduit from high-voltage input and output power feeds to prevent electromagnetic noise coupling.

Installation Guidelines

CRITICAL WARNING:

Ensure all main power sources (L1, L2, L3) are locked out and tagged out prior to making physical connections. Wait a minimum of 10 minutes after disconnecting power for internal capacitors to fully discharge. Always verify that the DC bus voltage across terminals P/+ and N/- has dropped below 50 VDC using a certified multimeter before handling drive wiring.

1

Mount the inverter vertically to a rigid, flat metal backplate using the integrated mounting brackets to maximize heat dissipation.

2

Connect incoming 3-phase power line wiring to terminals L1, L2, and L3. Connect the three motor power leads to terminals U, V, and W.

3

Establish protective ground connections at the ground terminal. Ensure connection resistance is under 10 ohms (Class D grounding).

4

Apply power and use the digital operator panel or CX-Drive software to set critical motor parameters, including rated current, base frequency, and control selection mode.

What is the differences between the ZV1 variant and older 3G3MX2 models?

The -ZV1 model features updated firmware that supports advanced functional safety standards and enhanced parameter transfer options, while remaining fully backwards-compatible for legacy 3G3MX2-A4015 applications.

Does this drive support single-phase input voltage?

No. The 3G3MX2-A4015-ZV1 is designed strictly for three-phase 380 to 480 VAC supply. Operating it on a single-phase supply can cause phase loss protection faults and thermal overloading.

How do I clear an overcurrent fault (E01 to E04) on startup?

Check the acceleration time parameter (F002) and lengthen it. Additionally, verify motor insulation, ensure the motor capacity matches the drive's CT setting, and confirm the motor shaft is free to spin without mechanical blockages.

Is an external contactor required to meet functional safety standards?

No. The integrated dual-channel Safe Torque Off (STO) function complies with ISO 13849-1 PLd, meaning safe power interruption to the motor can be managed directly by the drive's safety inputs without external mains contactors.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...