Description

The 140DII33000 is a specialized Digital Input Module for the Modicon Quantum automation platform, engineered specifically for environments requiring Intrinsically Safe (IS) operation. This module features 8 digital input channels designed to handle DC signals while maintaining the safety standards necessary for hazardous industrial locations. As a key component of the Quantum I/O architecture, the 140DII33000 provides secure and reliable signal acquisition in demanding process control applications where explosive atmospheres may be present.

Features

  • Compatible with the Modicon Quantum PLC system
  • Provides 8 digital input channels
  • Designed for Intrinsically Safe (IS) applications
  • Engineered for safe operation in hazardous industrial environments
  • Robust module construction for high-reliability process control

Applications

  • Hazardous area process automation
  • Oil and gas industry control systems
  • Chemical and petrochemical processing plants
  • Intrinsic safety-rated instrumentation interfaces
  • Industrial monitoring in potentially explosive environments

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Modicon Quantum
Product Type Digital Input Module
Model 140DII33000
Number of Inputs 8
Input Type DC, Intrinsically Safe
Commodity Code 85371091
Product Phase Phase-Out
Weight 1.78 kg

Installation Guidelines

  • Safety Precautions: Since this is an Intrinsically Safe module, ensure installation complies with all local and national safety standards regarding hazardous area equipment.
  • Separation: Maintain required physical separation between intrinsically safe wiring and non-intrinsically safe wiring to prevent cross-contamination of signals.
  • Grounding: Proper grounding of the Quantum backplane and the IS barrier systems is critical for maintaining safety integrity.
  • Handling: Avoid handling the module in hazardous areas while power is applied. Always use approved tools and procedures for installation in explosion-prone environments.
  • Compatibility: Verify that the connected field devices are approved for use with this intrinsically safe module and that system parameters match the safety documentation.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What does 'Intrinsically Safe' mean for the 140DII33000?
It means the module is designed and certified for safe operation in potentially hazardous or explosive industrial environments by limiting electrical and thermal energy.
How many inputs does the 140DII33000 support?
The module provides 8 digital input channels.
Which system is this module compatible with?
It is designed specifically for the Modicon Quantum automation platform.
Is this product still in active production?
No, the 140DII33000 is classified as a phase-out product.
Reviews

140DII33000

Stock & lead time on request

Call
1 su 1

Schneider Modicon Quantum 140DII33000 Digital Input Module

Only 5 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: 140DII33000

  • Country of origin:France

  • Product Type: Digital Modules

  • Payment: T/T, Western Union

  • Weight: 1780g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The 140DII33000 is a specialized Digital Input Module for the Modicon Quantum automation platform, engineered specifically for environments requiring Intrinsically Safe (IS) operation. This module features 8 digital input channels designed to handle DC signals while maintaining the safety standards necessary for hazardous industrial locations. As a key component of the Quantum I/O architecture, the 140DII33000 provides secure and reliable signal acquisition in demanding process control applications where explosive atmospheres may be present.

Features

  • Compatible with the Modicon Quantum PLC system
  • Provides 8 digital input channels
  • Designed for Intrinsically Safe (IS) applications
  • Engineered for safe operation in hazardous industrial environments
  • Robust module construction for high-reliability process control

Applications

  • Hazardous area process automation
  • Oil and gas industry control systems
  • Chemical and petrochemical processing plants
  • Intrinsic safety-rated instrumentation interfaces
  • Industrial monitoring in potentially explosive environments

Technical Specifications

Feature Specification
Manufacturer Schneider Electric
Range Modicon Quantum
Product Type Digital Input Module
Model 140DII33000
Number of Inputs 8
Input Type DC, Intrinsically Safe
Commodity Code 85371091
Product Phase Phase-Out
Weight 1.78 kg

Installation Guidelines

  • Safety Precautions: Since this is an Intrinsically Safe module, ensure installation complies with all local and national safety standards regarding hazardous area equipment.
  • Separation: Maintain required physical separation between intrinsically safe wiring and non-intrinsically safe wiring to prevent cross-contamination of signals.
  • Grounding: Proper grounding of the Quantum backplane and the IS barrier systems is critical for maintaining safety integrity.
  • Handling: Avoid handling the module in hazardous areas while power is applied. Always use approved tools and procedures for installation in explosion-prone environments.
  • Compatibility: Verify that the connected field devices are approved for use with this intrinsically safe module and that system parameters match the safety documentation.

What does 'Intrinsically Safe' mean for the 140DII33000?

It means the module is designed and certified for safe operation in potentially hazardous or explosive industrial environments by limiting electrical and thermal energy.

How many inputs does the 140DII33000 support?

The module provides 8 digital input channels.

Which system is this module compatible with?

It is designed specifically for the Modicon Quantum automation platform.

Is this product still in active production?

No, the 140DII33000 is classified as a phase-out product.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
France
Power source
DC Power

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...