Siemens

Siemens 6SL3000-0BE28-0AA0 | Siemens | SINAMICS / SIMODRIVE 611 Line Filter

SKU 6SL3000-0BE28-0AA0

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 6SL3000-0BE28-0AA0
  • Origin Germany
  • Product Type: Active line Modules
  • Barcode: 85363090
  • Payment: T/T, Western Union
  • Weight: 25.4 kg
  • Dimensions: 35.60cm x 20.30cm x 53.30cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

The 6SL3000-0BE28-0AA0 is a high-performance Line Filter engineered to complement 80 kW Active Line Modules (ALM) within the SINAMICS and SIMODRIVE 611 drive families. This component is essential for maintaining electromagnetic compatibility (EMC) by suppressing high-frequency interference generated by the switching action of the drive's power electronics. By providing a clean power interface, this filter ensures the longevity and stable operation of connected automation hardware.

Features

  • EMC Compliance: Specifically designed to suppress electromagnetic interference (EMI) and radio frequency interference (RFI) to meet industrial standards.
  • Optimized for ALM: Rated for use with 80 kW Active Line Modules, ensuring efficient energy conversion and grid-friendly operation.
  • Wide Voltage Range: Supports standard industrial supplies of 380-480 V (3AC) at 50/60 Hz.
  • Robust Thermal & Electrical Specs: Built for the high power demands of large-scale industrial drives, managing an input of up to 80 kW reliably.

Applications

  • Large-scale automation systems involving high-power motor drives.
  • CNC machining and heavy-duty manufacturing production lines.
  • Industrial setups where signal integrity is critical for PLC or sensor stability.
  • Retrofitting or maintenance of SINAMICS and SIMODRIVE 611 multi-drive configurations.

Technical Specifications

Parameter Specification
Manufacturer Siemens
Model 6SL3000-0BE28-0AA0
Range SINAMICS / SIMODRIVE
Product Type Line Filter (for Active Line Module)
Rated Power 80 kW
Input Voltage 3AC 380-480V
Input Frequency 50/60 Hz
Dimensions 35.60 cm x 20.30 cm x 53.30 cm
Weight 25.40 kg
Product Phase Phase-Out
Commodity Code 85363090

Installation Guidelines

  • Placement: The line filter should be installed as close as possible to the Active Line Module to minimize the length of unfiltered cable, which reduces the potential for radiated interference.
  • Grounding: Proper bonding to the cabinet’s protective earth (PE) system is crucial. The filter housing must have a large-surface-area connection to the grounded mounting plate to effectively drain high-frequency noise.
  • Wiring: Keep input cables (from the supply) separate from output cables (to the ALM) to prevent "crosstalk" where filtered signals could be re-contaminated by the noisy, unfiltered input cabling.
  • Thermal Considerations: Given the unit's power capacity and weight, ensure the mounting backplane in the cabinet is rated for 25.40 kg and provides sufficient ventilation to prevent thermal accumulation.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the 6SL3000-0BE28-0AA0?
It serves as a line filter to suppress electromagnetic interference (EMI) and improve power quality for 80 kW Active Line Modules in SINAMICS/SIMODRIVE drive systems.
Why is a line filter necessary for an Active Line Module?
Active Line Modules use high-frequency switching to achieve energy efficiency and grid regeneration; the line filter is required to limit the resulting harmonic emissions and noise back onto the power grid.
What is the weight of this component?
The 6SL3000-0BE28-0AA0 weighs 25.40 kg.
What does the 'Phase-Out' status mean for this product?
It means the product is nearing the end of its lifecycle and is primarily recommended for the maintenance and repair of existing installations rather than new-build projects.
Reviews

6SL3000-0BE28-0AA0

Stock & lead time on request

Call
1 su 1

Siemens 6SL3000-0BE28-0AA0 | Siemens | SINAMICS / SIMODRIVE 611 Line Filter

Only 5 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6SL3000-0BE28-0AA0

  • Country of origin:Germany

  • Product Type: Active line Modules

  • Barcode: 85363090

  • Payment: T/T, Western Union

  • Weight: 25400g

  • Dimensions: 35.60cm x 20.30cm x 53.30cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

The 6SL3000-0BE28-0AA0 is a high-performance Line Filter engineered to complement 80 kW Active Line Modules (ALM) within the SINAMICS and SIMODRIVE 611 drive families. This component is essential for maintaining electromagnetic compatibility (EMC) by suppressing high-frequency interference generated by the switching action of the drive's power electronics. By providing a clean power interface, this filter ensures the longevity and stable operation of connected automation hardware.

Features

  • EMC Compliance: Specifically designed to suppress electromagnetic interference (EMI) and radio frequency interference (RFI) to meet industrial standards.
  • Optimized for ALM: Rated for use with 80 kW Active Line Modules, ensuring efficient energy conversion and grid-friendly operation.
  • Wide Voltage Range: Supports standard industrial supplies of 380-480 V (3AC) at 50/60 Hz.
  • Robust Thermal & Electrical Specs: Built for the high power demands of large-scale industrial drives, managing an input of up to 80 kW reliably.

Applications

  • Large-scale automation systems involving high-power motor drives.
  • CNC machining and heavy-duty manufacturing production lines.
  • Industrial setups where signal integrity is critical for PLC or sensor stability.
  • Retrofitting or maintenance of SINAMICS and SIMODRIVE 611 multi-drive configurations.

Technical Specifications

Parameter Specification
Manufacturer Siemens
Model 6SL3000-0BE28-0AA0
Range SINAMICS / SIMODRIVE
Product Type Line Filter (for Active Line Module)
Rated Power 80 kW
Input Voltage 3AC 380-480V
Input Frequency 50/60 Hz
Dimensions 35.60 cm x 20.30 cm x 53.30 cm
Weight 25.40 kg
Product Phase Phase-Out
Commodity Code 85363090

Installation Guidelines

  • Placement: The line filter should be installed as close as possible to the Active Line Module to minimize the length of unfiltered cable, which reduces the potential for radiated interference.
  • Grounding: Proper bonding to the cabinet’s protective earth (PE) system is crucial. The filter housing must have a large-surface-area connection to the grounded mounting plate to effectively drain high-frequency noise.
  • Wiring: Keep input cables (from the supply) separate from output cables (to the ALM) to prevent "crosstalk" where filtered signals could be re-contaminated by the noisy, unfiltered input cabling.
  • Thermal Considerations: Given the unit's power capacity and weight, ensure the mounting backplane in the cabinet is rated for 25.40 kg and provides sufficient ventilation to prevent thermal accumulation.
Key Features:

What is the primary function of the 6SL3000-0BE28-0AA0?

It serves as a line filter to suppress electromagnetic interference (EMI) and improve power quality for 80 kW Active Line Modules in SINAMICS/SIMODRIVE drive systems.

Why is a line filter necessary for an Active Line Module?

Active Line Modules use high-frequency switching to achieve energy efficiency and grid regeneration; the line filter is required to limit the resulting harmonic emissions and noise back onto the power grid.

What is the weight of this component?

The 6SL3000-0BE28-0AA0 weighs 25.40 kg.

What does the 'Phase-Out' status mean for this product?

It means the product is nearing the end of its lifecycle and is primarily recommended for the maintenance and repair of existing installations rather than new-build projects.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...